Irma SL Blood Analysis System GL Cartridge

K011586510(k) TraditionalCleared Nov 16, 2001177-day reviewClass I21 CFR 878.4800

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Diametrics Medical, Inc. · GAA Needle, Aspiration And Injection, Disposable

Cleared on Nov 16, 2001 as substantially equivalent to K891480 (Yellow Springs Instrument Co., Inc., 1989) after a 177-day review. Its family tree reaches back 1 generation to 1989.

Decided
Nov 16, 2001
Review
177 days
Class
Class I
Product code
GAA
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to K891480 (1989). No later device cites it as a predicate yet.

  1. Root · 1 generation backK891480 Ysi Model 2300 Stat Glucose and L-Lactate AnalyzerYellow Springs Instrument Co., Inc. · 1989
  2. This deviceK011586 Irma SL Blood Analysis System GL CartridgeDiametrics Medical, Inc. · 2001
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K891480Ysi Model 2300 Stat Glucose and L-Lactate AnalyzerYellow Springs Instrument Co., Inc.1989—
0 (this device)K011586Irma SL Blood Analysis System GL CartridgeDiametrics Medical, Inc.2001—
FIG. 1 — Lineage of K011586, 1989–2001Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in GAA? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GAA device

  1. #1 K223625 CapnoSpot™ Pneumothorax Decompression Indicatorscore 5.1 · 1 generation · no Class I recall
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K891480Ysi Model 2300 Stat Glucose and L-Lactate Analyzer
Summary page 1
…,2001 GL Cartridge IRMA?® SL Blood Analysis System GL Cartridge Glucose Test System Glucose Class I 21 CFR 862.1345 Chemistry (75) CGA YSI Model 2300 Stat Plus. K891480 75 CGA The IRMA® SL Blood Analysis System GL Cartridge is substantially equivalent in method, intended use and clinical perform…
Yellow Springs Instrument Co., Inc.1989—

Also cleared against K891480: 2 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has no recall.
  • 2 other devices also cite its predicate K891480.

How does its category compare?

All GAA devices

GAA Needle, Aspiration And Injection, Disposable: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · GAA

1in 2023

2011: 12023: 1
2007high 1 (2011) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GAA

Too few GAA 510(k)s in any year since 2007 to give a median.

Recalls per year · GAA

2in 2022

2008: 12009: 22010: 22019: 102021: 52022: 2
2007high 10 (2019) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · GAA

348in 2025

2007: 122008: 322009: 202010: 182011: 92012: 242013: 332014: 242015: 322016: 452017: 852018: 1222019: 1532020: 1022021: 1082022: 742023: 1182024: 1812025: 348
2007high 348 (2025) · low 9 (2011)2025

MAUDE reports naming product code GAA, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—012
20080—132
20090—220
20100—218
20111—09
20120—024
20130—033
20140—024
20150—032
20160—045
20170—085
20180—0122
20190—10153
20200—0102
20210—5108
20220—274
20231—0118
20240—0181
20250—0348
20260—0—

What is it indicated for?

The glucose sensor is intended for professional use with the IRMA® Blood Analysis System for the direct measurement of glucose, in human whole blood. The GL Cartridge and the IRMA® Blood Analysis System are for in vitro diagnostic use.

The measurement of glucose aids in the diagnosis and treatment of diabetes mellitus, neonatal hypoglycemia and idiopathic hypoglycemia.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K011586: Irma SL Blood Analysis System GL Cartridge.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K011586

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 30, 2026 (extraction version 2d9447fa9ea4)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026