Irma SL Blood Analysis System Lactate Cartridge

K013938510(k) TraditionalCleared Jan 28, 200261-day reviewClass I21 CFR 862.1450

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Diametrics Medical, Inc. · KHP Acid, Lactic, Enzymatic Method

Cleared on Jan 28, 2002 as substantially equivalent to K891480 (Yellow Springs Instrument Co., Inc., 1989) after a 61-day review. Its family tree reaches back 1 generation to 1989.

Decided
Jan 28, 2002
Review
61 days
Class
Class I
Product code
KHP
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to K891480 (1989). No later device cites it as a predicate yet.

  1. Root · 1 generation backK891480 Ysi Model 2300 Stat Glucose and L-Lactate AnalyzerYellow Springs Instrument Co., Inc. · 1989
  2. This deviceK013938 Irma SL Blood Analysis System Lactate CartridgeDiametrics Medical, Inc. · 2002
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K891480Ysi Model 2300 Stat Glucose and L-Lactate AnalyzerYellow Springs Instrument Co., Inc.1989—
0 (this device)K013938Irma SL Blood Analysis System Lactate CartridgeDiametrics Medical, Inc.2002—
FIG. 1 — Lineage of K013938, 1989–2002Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in KHP? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K891480Ysi Model 2300 Stat Glucose and L-Lactate Analyzer
Summary page 1
…lood Analysis System Lactate Cartridge Lactic Acid Test System Acid, Lactic, Enzymatic Method Class I 21 CFR 862.1450 Chemistry (75) KHP YSI Model 2300 Stat Plus. K891480 75 CGA The IRMA® SL Blood Analysis System GL Cartridge is substantially equivalent in method, intended use and clinical perform…
Yellow Springs Instrument Co., Inc.1989—

Also cleared against K891480: 2 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has no recall.
  • 2 other devices also cite its predicate K891480.

How does its category compare?

All KHP devices

KHP Acid, Lactic, Enzymatic Method: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · KHP

1in 2013

2010: 12011: 22012: 22013: 1
2007high 2 (2011) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · KHP

Too few KHP 510(k)s in any year since 2007 to give a median.

Recalls per year · KHP

3in 2016

2014: 12016: 3
2007high 3 (2016) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · KHP

9in 2025

2010: 22011: 22012: 32013: 122014: 192015: 122016: 412017: 92018: 122019: 102020: 62021: 32022: 72023: 32024: 132025: 9
2007high 41 (2016) · low 0 (2007)2025

MAUDE reports naming product code KHP, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20101—02
20112—02
20122—03
20131—012
20140—119
20150—012
20160—341
20170—09
20180—012
20190—010
20200—06
20210—03
20220—07
20230—03
20240—013
20250—09
20260—0—

What is it indicated for?

The lactate sensor is intended for professional and point of care use with the IRMA® Blood Analysis System for the direct measurement of lactate, in human whole blood. The Lactate Cartridge and the IRMA® Blood Analysis System are for in vitro diagnostic use.

Lactate evaluates the acid-base status and is used in the diagnosis and treatment of lactic acidosis (abnormally high acidity of the blood).

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K013938: Irma SL Blood Analysis System Lactate Cartridge.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K013938

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 30, 2026 (extraction version 2d9447fa9ea4)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026