510(k) Report

510(k) · Cleared

Recalled · Class II · 2023

Scorpio CR Superflex Tibial Insert

K011643510(k) SpecialCleared Jun 28, 200130-day reviewClass II21 CFR 888.3560Recalls 2

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Howmedica Osteonics Corp. · JWH Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer

Cleared on Jun 28, 2001 as substantially equivalent to K974556 (Osteonics Corp., 1998) after a 30-day review. Its family tree reaches back 1 generation to 1998. 5 later devices descend from it. It has been recalled 2 times.

Decided
Jun 28, 2001
Review
30 days
Class
Class II
Product code
JWH
Recalls
2
Predicates
1

Its longest line of descent runs back 1 generation to K974556 (1998). 5 later devices descend from it, 3 citing it directly.

Descendants, by year cleared 2025: 2 descendants cleared2024: 1 descendant cleared2026: 2 descendants clearedK974556 · Osteonics Scorpio Posterior Cruciate Retaining Total Knee System · Osteonics Corp. · 1998 · recalled1995200020052010201520202025
Descendants, by generation 1 generation forward: 3 descendants2 generations forward: 2 descendants K974556 · Osteonics Scorpio Posterior Cruciate Retaining Total Knee System · Osteonics Corp. · 1998 · recalled0
  1. Root · 1 generation backK974556 Osteonics Scorpio Posterior Cruciate Retaining Total Knee SystemOsteonics Corp. · 1998 · Recalled
  2. This deviceK011643 Scorpio CR Superflex Tibial InsertHowmedica Osteonics Corp. · 2001
  3. Descendant · cites it directly · 2 of its ownK243817 Scorpio Universal Dome Patella; Scorpio Total Stabilizer Insert…Howmedica Osteonics Corp., Dba Stryker Orthopaedics · 2025 · Recalled
  4. Descendant · cites it directly · 1 of its ownK234044 ACS® LD FB Knee SystemImplantcast GmbH · 2024
  5. Descendant · cites it directly · 0 of its ownK261898 Triathlon® Knee System; Triathlon® Hinge Knee System; Scorpio® Total…Howmedica Osteonics Corp. dba Stryker Orthopaedics · 2026
  6. Descendant · 2 generations on · 0 of its ownK260037 implantcast Packaging System UpdateImplantcast GmbH · 2026
  7. Descendant · 2 generations on · 0 of its ownK252898 Triathlon® Tritanium® Asymmetric Patella; Triathlon® Tritanium®…Howmedica Osteonics Corp., Dba Stryker Orthopaedics · 2025 · Recalled

Most influential descendants

Showing 5 of 5 · See all
  • K243817Scorpio Universal Dome Patella; Scorpio Total Stabilizer Insert; Scorpio-Flex Posterior…Howmedica Osteonics Corp., Dba Stryker Orthopaedics · 2025 · cites it directly2descendants
  • K234044ACS® LD FB Knee SystemImplantcast GmbH · 2024 · cites it directly1descendant
  • K261898Triathlon® Knee System; Triathlon® Hinge Knee System; Scorpio® Total Knee SystemHowmedica Osteonics Corp. dba Stryker Orthopaedics · 2026 · cites it directly0descendants
  • K260037implantcast Packaging System UpdateImplantcast GmbH · 2026 · 2 generations on0descendants
  • K252898Triathlon® Tritanium® Asymmetric Patella; Triathlon® Tritanium® Symmetric Patella…Howmedica Osteonics Corp., Dba Stryker Orthopaedics · 2025 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K974556Osteonics Scorpio Posterior Cruciate Retaining Total Knee SystemOsteonics Corp.19987
0 (this device)K011643Scorpio CR Superflex Tibial InsertHowmedica Osteonics Corp.2001—
+1K243817Scorpio Universal Dome Patella; Scorpio Total Stabilizer Insert; Scorpio-Flex…Howmedica Osteonics Corp., Dba Stryker Orthopaedics20252
+1K234044ACS® LD FB Knee SystemImplantcast GmbH2024—
+1K261898Triathlon® Knee System; Triathlon® Hinge Knee System; Scorpio® Total Knee SystemHowmedica Osteonics Corp. dba Stryker Orthopaedics2026—
+2K260037implantcast Packaging System UpdateImplantcast GmbH2026—
+2K252898Triathlon® Tritanium® Asymmetric Patella; Triathlon® Tritanium® Symmetric…Howmedica Osteonics Corp., Dba Stryker Orthopaedics20251

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202410
202520
202620
FIG. 1 — Lineage of K011643, 1998–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in JWH? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new JWH device

  1. #1 K221479 Persona Personalized Knee Systemscore 22.4 · 11 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K974556Osteonics Scorpio Posterior Cruciate Retaining Total Knee System
Summary page 1
…60 Predicate Device Identification The Scorpio® CR Superflex™ Tibial Bearing Inserts are substantially equivalent to the Scorpio® CR Tibial Bearing Inserts cleared via K974556. Device Description The Scorpio® CR Superflex™ tibial inserts share the same critical design features as the predicate Scorpio®…
Osteonics Corp.19987

Also cleared against K974556: 11 other devices →

What descends from it? (5)

3 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K243817Scorpio Universal Dome Patella; Scorpio Total Stabilizer Insert; Scorpio-Flex Posterior…Howmedica Osteonics Corp., Dba Stryker Orthopaedics20252
K234044ACS® LD FB Knee SystemImplantcast GmbH20241
K261898Triathlon® Knee System; Triathlon® Hinge Knee System; Scorpio® Total Knee SystemHowmedica Osteonics Corp. dba Stryker Orthopaedics20260

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Dec 1, 2023Class IIZ-0884-2024Nonconforming Material/ComponentProduct manufactured using UHMWPE raw material over 5 years of age has the potential for elevated levels of oxidation. Oxidation within UHMWPE can have an impact on its material properties.
Dec 1, 2023Class IIZ-0885-2024Nonconforming Material/ComponentProduct manufactured using UHMWPE raw material over 5 years of age has the potential for elevated levels of oxidation. Oxidation within UHMWPE can have an impact on its material properties.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has a recall.
  • Of its descendants, K243817 (Howmedica Osteonics Corp., Dba Stryker Orthopaedics, 2025) has gone furthest, with 2 descendants of its own.
  • 11 other devices also cite its predicate K974556.

How does its category compare?

All JWH devices

JWH Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · JWH

20in 2025

2007: 182008: 172009: 112010: 192011: 252012: 332013: 312014: 332015: 272016: 182017: 252018: 252019: 282020: 222021: 242022: 172023: 202024: 192025: 202026 (partial year): 12
2007high 33 (2012) · low 11 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · JWH

55in 2025

2007: 74 days median2008: 81 days median2009: 168 days median2010: 85 days median2011: 87 days median2012: 85 days median2013: 128 days median2014: 98 days median2015: 87 days median2016: 88 days median2017: 118 days median2018: 90 days median2019: 133 days median2020: 59 days median2021: 61 days median2022: 56 days median2023: 57 days median2024: 89 days median2025: 55 days median2026 (partial year): 63 days median
2007high 168 (2009) · low 55 (2025)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · JWH

2in 2025

2007: 142008: 102009: 1092010: 322011: 272012: 852013: 312014: 132015: 112016: 172017: 612018: 142019: 52020: 22021: 82022: 122023: 672024: 72025: 22026 (partial year): 4
2007high 109 (2009) · low 2 (2020)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · JWH

9,306in 2025

2007: 1,3052008: 1,4832009: 1,8702010: 3,2862011: 5,1332012: 5,2032013: 6,1352014: 6,7222015: 6,8812016: 7,5862017: 12,2632018: 14,0712019: 14,9872020: 12,5922021: 9,4082022: 8,3642023: 8,9472024: 10,8282025: 9,306
2007high 14,987 (2019) · low 1,305 (2007)2025

MAUDE reports naming product code JWH, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071874141,305
20081781101,483
2009111681091,870
20101985323,286
20112587275,133
20123385855,203
201331128316,135
20143398136,722
20152787116,881
20161888177,586
2017251186112,263
201825901414,071
201928133514,987
20202259212,592
2021246189,408
20221756128,364
20232057678,947
20241989710,828
2025205529,306
202612634—

What is it indicated for?

The Scorpio® CR Superflex™ Tibial Bearing Inserts are single use devices. They are intended for mating with commercially available Howmedica Osteonics tibial trays and patellas and Scorpio® Total Knee CR femoral components, which are intended for cemented fixation. The indications for the modified Scorpio® CR Superflex™ tibial inserts will remain the same as the indications for the current Scorpio® CR inserts. These are: Painful, disabling joint disease…

Read the full statement (115 words)

The Scorpio® CR Superflex™ Tibial Bearing Inserts are single use devices. They are

intended for mating with commercially available Howmedica Osteonics tibial trays and

patellas and Scorpio® Total Knee CR femoral components, which are intended for

cemented fixation.

The indications for the modified Scorpio® CR Superflex™ tibial inserts will remain the same

as the indications for the current Scorpio® CR inserts. These are:

Painful, disabling joint disease of the knee resulting from: degenerative arthritis,

rheumatoid arthritis or post-traumatic arthritis

Post-traumatic loss of knee joint configuration and function

Moderate varus, valgus, or flexion deformity in which the ligamentous structures can

be returned to adequate function and stability

Revision of previous unsuccessful knee replacement or other procedure

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K011643: Scorpio CR Superflex Tibial Insert.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K011643

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 30, 2026 (extraction version 2d9447fa9ea4)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026