510(k) Report

510(k) · Cleared

Cleared

Klimamed Thermal Mat & Controller 95 and 55 Watts

K011859510(k) TraditionalCleared May 1, 2002321-day reviewClass II21 CFR 870.5900

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Klimamed Technologie Medizingerate GmbH · DWJ System, Thermal Regulating

Cleared on May 1, 2002 after a 321-day review. The FDA summary names its predicate without a number. 13 later devices descend from it.

Decided
May 1, 2002
Review
321 days
Class
Class II
Product code
DWJ
Recalls
None
Predicates
0

13 later devices descend from it, 4 citing it directly.

Descendants, by year cleared 2006: 3 descendants cleared2004: 1 descendant cleared2008: 1 descendant cleared2009: 1 descendant cleared2012: 1 descendant cleared2010: 1 descendant cleared2013: 1 descendant cleared2020: 1 descendant cleared2022: 1 descendant cleared2023: 1 descendant cleared2024: 1 descendant cleared200020052010201520202025
  1. This deviceK011859 Klimamed Thermal Mat & Controller 95 and 55 WattsKlimamed Technologie Medizingerate GmbH · 2002
  2. Descendant · cites it directly · 10 of its ownK031728 Klimamed Thermal Blankets, Including Arm Shoulder West Thermal…Klimamed Technologie Medizingerate GmbH · 2004
  3. Descendant · cites it directly · 9 of its ownK051419 Inditherm Patient Warming System, Models MECU1; OTM1; OTM2; GTM1…Inditherm Medical · 2006
  4. Descendant · 2 generations on · 6 of its ownK092807 Hot Dog Patient Warming Mattress System, Models Wcub, M101, M102 and…Augustine Biomedical & Design, LLC · 2009
  5. Descendant · 3 generations on · 4 of its ownK094056 Hotdog Multi Function ControllerAugustine Biomedical & Design, LLC · 2010
  6. Descendant · 4 generations on · 3 of its ownK201779 HotDog Temperature Management ControllerAugustine Temperature Management · 2020 · Recalled

Showing 5 of 13 descendants. See all descendants

Descendants cleared per year

2004: 12006: 32008: 12009: 12010: 12012: 12013: 12020: 12022: 12023: 12024: 1
2004high 3 (2006) · low 0 (2005)2026

Most influential descendants

Showing 5 of 13 · See all
  • K031728Klimamed Thermal Blankets, Including Arm Shoulder West Thermal Blanket and Leg Warmer…Klimamed Technologie Medizingerate GmbH · 2004 · cites it directly10descendants
  • K051419Inditherm Patient Warming System, Models MECU1; OTM1; OTM2; GTM1; PTM1; Otb; RB1Inditherm Medical · 2006 · cites it directly9descendants
  • K092807Hot Dog Patient Warming Mattress System, Models Wcub, M101, M102 and M103Augustine Biomedical & Design, LLC · 2009 · 2 generations on6descendants
  • K094056Hotdog Multi Function ControllerAugustine Biomedical & Design, LLC · 2010 · 3 generations on4descendants
  • K201779HotDog Temperature Management ControllerAugustine Temperature Management · 2020 · 4 generations on3descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K011859Klimamed Thermal Mat & Controller 95 and 55 WattsKlimamed Technologie Medizingerate GmbH2002—
+1K031728Klimamed Thermal Blankets, Including Arm Shoulder West Thermal Blanket and Leg…Klimamed Technologie Medizingerate GmbH2004—
+1K051419Inditherm Patient Warming System, Models MECU1; OTM1; OTM2; GTM1; PTM1; Otb; RB1Inditherm Medical2006—
+2K092807Hot Dog Patient Warming Mattress System, Models Wcub, M101, M102 and M103Augustine Biomedical & Design, LLC2009—
+3K094056Hotdog Multi Function ControllerAugustine Biomedical & Design, LLC2010—
+4K201779HotDog Temperature Management ControllerAugustine Temperature Management20204

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200410
200630
200810
200910
201010
201210
201310
202010
202210
202310
202410
FIG. 1 — Lineage of K011859, 2002–2024Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DWJ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DWJ device

  1. #1 K260278 ThermAffyx (TM) Patient Safety Systemscore 12.8 · 5 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*—Allon 2001
Named without a submission number
—

What descends from it? (13)

See all 13

4 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K031728Klimamed Thermal Blankets, Including Arm Shoulder West Thermal Blanket and Leg Warmer…Klimamed Technologie Medizingerate GmbH200410
K051419Inditherm Patient Warming System, Models MECU1; OTM1; OTM2; GTM1; PTM1; Otb; RB1Inditherm Medical20069
K062794PRN Thermalcare, Model 3000American Healthcare Products, Inc.20062
K080763Tablegard Pressure Relieving Patient Warming Mattress, Model: TG 700 HTTalley Medical20080

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K031728 (Klimamed Technologie Medizingerate GmbH, 2004) has gone furthest, with 10 descendants of its own.

How does its category compare?

All DWJ devices

DWJ System, Thermal Regulating: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · DWJ

3in 2025

2007: 42008: 32009: 32010: 82011: 42012: 52013: 52014: 42016: 22017: 52018: 32019: 22020: 52021: 22022: 22023: 62024: 22025: 32026 (partial year): 5
2007high 8 (2010) · low 0 (2015)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DWJ

131in 2025

2007: 106 days median2008: 73 days median2009: 106 days median2010: 134 days median2011: 180 days median2012: 69 days median2013: 77 days median2014: 131 days median2017: 153 days median2018: 95 days median2020: 30 days median2023: 42 days median2025: 131 days median2026 (partial year): 99 days median
2007high 180 (2011) · low 30 (2020)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DWJ

3in 2024

2009: 62010: 22011: 72012: 12013: 22015: 12017: 32018: 52019: 32020: 22021: 12022: 52024: 32026 (partial year): 3
2007high 7 (2011) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · DWJ

2,384in 2025

2007: 522008: 402009: 712010: 1042011: 1362012: 1062013: 732014: 1162015: 2452016: 1,4002017: 1,4732018: 1,5172019: 2,2942020: 2,5462021: 2,6892022: 3,2262023: 3,4552024: 3,3292025: 2,384
2007high 3,455 (2023) · low 40 (2008)2025

MAUDE reports naming product code DWJ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20074106052
2008373040
20093106671
201081342104
201141807136
20125691106
2013577273
201441310116
20150—1245
20162—01,400
2017515331,473
201839551,517
20192—32,294
202053022,546
20212—12,689
20222—53,226
202364203,455
20242—33,329
2025313102,384
20265993—

What is it indicated for?

The device is intended to maintain pre-set body temperature as determined by the physician. It can also be utilized to maintain normal body temperature during surgical procedures. It is indicated for use in hospital invasive and coronary care units, in operating, recovery and emergency rooms, in burn units, and on medical / surgical floors

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K011859: Klimamed Thermal Mat & Controller 95 and 55 Watts.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K011859

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 30, 2026 (extraction version 2d9447fa9ea4)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026