510(k) Report

510(k) · Cleared

Recalled · Class II · 2014

Glucose (Hexokinase)

K011900510(k) TraditionalCleared Jul 31, 200143-day reviewClass II21 CFR 862.1345Recalls 2

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Jas Diagnostics, Inc. · CFR Hexokinase, Glucose

Cleared on Jul 31, 2001 after a 43-day review. FDA’s file for it is a 510(k) statement, which names no predicate. 1 later device descends from it. It has been recalled 2 times.

Decided
Jul 31, 2001
Review
43 days
Class
Class II
Product code
CFR
Recalls
2
Predicates
0

1 later device descends from it, 1 citing it directly.

Descendants, by year cleared 2007: 1 descendant cleared200020052010201520202025
  1. This deviceK011900 Glucose (Hexokinase)Jas Diagnostics, Inc. · 2001
  2. Descendant · cites it directly · 0 of its ownK070704 Trilogy AnalyzerDrew Scientific, Inc. · 2007

Most influential descendants

Showing 1 of 1 · See all
  • K070704Trilogy AnalyzerDrew Scientific, Inc. · 2007 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K011900Glucose (Hexokinase)Jas Diagnostics, Inc.2001—
+1K070704Trilogy AnalyzerDrew Scientific, Inc.2007—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200710
FIG. 1 — Lineage of K011900, 2001–2007Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in CFR? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new CFR device

  1. #1 K253490 Glucose HK Gen.3; ONLINE DAT Methadone II…score 11.4 · 3 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against?

FDA’s file for it is a 510(k) statement, which names no predicate.

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K070704Trilogy AnalyzerDrew Scientific, Inc.20070

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Oct 23, 2014Class IIZ-0827-2015Under Investigation by firmProduct is not performing according to specifications. Control 2 does not consistently recover within its assigned range.
Apr 7, 2014Class IIZ-1873-2014Mixed-up of materials/componentsJAS Diagnostics, Inc. of Miami Lakes, FL is recalling their Glucose Hexokinase reagent due to certain lots not performing according to their specifications.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K070704 (Drew Scientific, Inc., 2007) has gone furthest, with 0 descendants of its own.

How does its category compare?

All CFR devices

CFR Hexokinase, Glucose: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · CFR

1in 2025

2007: 12008: 52009: 32011: 32012: 42013: 12014: 12016: 22017: 12019: 12022: 12025: 12026 (partial year): 1
2007high 5 (2008) · low 0 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · CFR

115in 2012

2008: 182 days median2009: 101 days median2011: 316 days median2012: 115 days median
2007high 316 (2011) · low 101 (2009)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · CFR

1in 2016

2008: 72009: 12012: 12014: 12016: 1
2007high 7 (2008) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · CFR

16in 2025

2007: 12008: 22009: 72010: 112011: 432012: 492013: 362014: 22015: 32016: 12017: 132018: 82019: 102020: 42021: 52022: 32023: 292024: 152025: 16
2007high 49 (2012) · low 1 (2007)2025

MAUDE reports naming product code CFR, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—01
2008518272
2009310117
20100—011
20113316043
20124115149
20131—036
20141—12
20150—03
20162—11
20171—013
20180—08
20191—010
20200—04
20210—05
20221—03
20230—029
20240—015
20251—016
20261—0—

What is it indicated for?

Intended for the In Vitro, quantitative determination of glucose in human serum on automated chemistry analyzers.

Glucose measurements are used in the diagnosis and treatment of carbohydrate metabolism disorders including diabetes mellitus, neonatal hypoglycemia, and idiopathic hypoglycemia, and of pancreatic islet cell carcinoma.

Indications for use read by OCR from a scanned FDA 510(k) statement, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K011900: Glucose (Hexokinase).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 3, 2026. https://510kreport.com/device/K011900

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 30, 2026 (extraction version 2d9447fa9ea4)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026