Comfortmate Fluid Warming System, Model # FW-200; Comfortmate Disporsable Disposable Warming Set, Model #FWS-200

K012832510(k) TraditionalCleared Oct 24, 200162-day reviewClass II21 CFR 880.5725

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Nxstage Medical, Inc. · LGZ Warmer, Thermal, Infusion Fluid

Cleared on Oct 24, 2001 as substantially equivalent to K973741 (Augustine Medical, Inc., 1998) and 1 other predicate after a 62-day review. Its family tree reaches back 1 generation to 1998. 1 of the 5 devices in its family, counting itself, has a Class I recall. 2 later devices descend from it.

Decided
Oct 24, 2001
Review
62 days
Class
Class II
Product code
LGZ
Recalls
None
Predicates
3

Its longest line of descent runs back 1 generation to K973741 (1998). 2 ancestors in all. 2 later devices descend from it, 1 citing it directly. 1 of the 5 devices in this family, counting this one, has a Class I recall.

Other ancestors, by year clearedDescendants, by year cleared 2001: 1 other ancestor2007: 1 descendant cleared2014: 1 descendant clearedK973741 · Bair Hugger Blood/Fluid Warmer · Augustine Medical, Inc. · 1998 · Class I recall1995200020052010201520202025
Other ancestors, by generationDescendants, by generation 1 generation back: 1 other ancestor 1 generation forward: 1 descendant2 generations forward: 1 descendant K973741 · Bair Hugger Blood/Fluid Warmer · Augustine Medical, Inc. · 1998 · Class I recall0
  1. Root · 1 generation backK973741 Bair Hugger Blood/Fluid WarmerAugustine Medical, Inc. · 1998 · Recalled (Class I)
  2. This deviceK012832 Comfortmate Fluid Warming System, Model # FW-200; Comfortmate…Nxstage Medical, Inc. · 2001
  3. Descendant · cites it directly · 1 of its ownK071263 Nxstage Travel Warmer, Models TW-400 & FWS-500Nxstage Medical, Inc. · 2007 · Recalled
  4. Descendant · 2 generations on · 0 of its ownK140623 Nxstage Express Fluid WarmerNxstage Medical, Inc. · 2014

Class I recalls in this family

Most influential descendants

Showing 2 of 2 · See all
  • K071263Nxstage Travel Warmer, Models TW-400 & FWS-500Nxstage Medical, Inc. · 2007 · cites it directly1descendant
  • K140623Nxstage Express Fluid WarmerNxstage Medical, Inc. · 2014 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K973741Bair Hugger Blood/Fluid WarmerAugustine Medical, Inc.1998Class I
0 (this device)K012832Comfortmate Fluid Warming System, Model # FW-200; Comfortmate Disporsable…Nxstage Medical, Inc.2001—
+1K071263Nxstage Travel Warmer, Models TW-400 & FWS-500Nxstage Medical, Inc.20071
+2K140623Nxstage Express Fluid WarmerNxstage Medical, Inc.2014—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200110

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200710
201410
FIG. 1 — Lineage of K012832, 1998–2014Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LGZ device

  1. #1 K260988 °M Warmer System with °M Stationscore 12.7 · 6 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary; numbers the summary cites that cannot be its predicate are marked – and kept off the family tree.

TypeNumberDeviceApplicantDecidedRecalls
*K973741Bair Hugger Blood/Fluid Warmer
Summary page 4
…nfusion Fluid C. Predicate Device Name: The predicate devices for the ComfortMate™ Fluid Warming System are the following: Warmer: Bair Hugger® Blood/Fluid Warmer - #K973741 (4/30/98); e MaxOne™ IV Fluid/Blood Warmer - #K002409 (6/28/01); * Medi-Temp Il FW300 Blood/Fluid Warmer — Originally 510(k)-cl…
Augustine Medical, Inc.1998Class I
*K002409Maxone, Blood, Blood Products and IV Fluid Warmer
Summary page 4
…devices for the ComfortMate™ Fluid Warming System are the following: Warmer: Bair Hugger® Blood/Fluid Warmer - #K973741 (4/30/98); e MaxOne™ IV Fluid/Blood Warmer - #K002409 (6/28/01); * Medi-Temp Il FW300 Blood/Fluid Warmer — Originally 510(k)-cleared as the Dupaco CounterFlo 300 Blood/Fluid Warmer S…
Automatic Medical Technologies, Inc.2001—
Kept off the family treeK950038Medi-Temp II FW300 Blood/Fluid Warmer (originally cleared as the Dupaco…
Not in FDA’s 510(k), De Novo or PMA lists as we hold them (a misreading, a typo, or a number FDA does not list), so it is kept off the family tree
Summary page 4
…V Fluid/Blood Warmer - #K002409 (6/28/01); * Medi-Temp Il FW300 Blood/Fluid Warmer — Originally 510(k)-cleared as the Dupaco CounterFlo 300 Blood/Fluid Warmer System - #K950038. Warmer Disposable: e Bair Hugger® Blood/Fluid Warmer - #K973741 (4/30/98); Medi-Temp Il FW300 Blood/Fiuid Warmer — Originally…

Also cleared against K973741: 6 other devices →

What descends from it? (2)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K071263Nxstage Travel Warmer, Models TW-400 & FWS-500Nxstage Medical, Inc.20071

Has anything in its family been recalled? (1 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K973741Bair Hugger Blood/Fluid WarmerAugustine Medical, Inc. · 1998 · Direct predicate · ◆ on the line of descent in FIG. 11 Class I recall

What does this lineage say?

  • 1 of the 2 ancestors has a recall of any class; 1 has a Class I recall.
  • Of its descendants, K071263 (Nxstage Medical, Inc., 2007) has gone furthest, with 1 descendant of its own.
  • 6 other devices also cite its predicate K973741.

How does its category compare?

All LGZ devices

LGZ Warmer, Thermal, Infusion Fluid: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · LGZ

2in 2025

2007: 22008: 42009: 22010: 22011: 32012: 72013: 52015: 22016: 22017: 22018: 12019: 32022: 32023: 12024: 12025: 22026 (partial year): 2
2007high 7 (2012) · low 0 (2014)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LGZ

546in 2022

2008: 99 days median2011: 77 days median2012: 162 days median2013: 143 days median2019: 209 days median2022: 546 days median
2007high 546 (2022) · low 77 (2011)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · LGZ

1in 2016

2009: 12010: 12011: 82015: 12016: 12026 (partial year): 1
2007high 8 (2011) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · LGZ

376in 2025

2007: 112008: 102009: 122010: 432011: 542012: 522013: 162014: 232015: 342016: 152017: 582018: 942019: 3402020: 1,2212021: 8852022: 1,5482023: 1,0332024: 8622025: 376
2007high 1,548 (2022) · low 10 (2008)2025

MAUDE reports naming product code LGZ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—011
2008499010
20092—112
20102—143
2011377854
20127162052
20135143016
20140—023
20152—134
20162—115
20172—058
20181—094
201932090340
20200—01,221
20210—0885
2022354601,548
20231—01,033
20241—0862
20252—0376
20262—1—

What is it indicated for?

The ComfortMate™ Filuid Warming System is intended to be used for the warming of fluids prior to administration.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K012832: Comfortmate Fluid Warming System, Model # FW-200; Comfortmate Disporsable Disposable Warming Set, Model #FWS-200.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K012832

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 30, 2026 (extraction version 2d9447fa9ea4)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026