Modification to Thermal Angel

K012031510(k) SpecialCleared Jul 26, 200128-day reviewClass II21 CFR 864.9205Recalls 1

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Estill Medical Technologies, Inc. · BSB Warmer, Blood, Non-Electromagnetic Radiation

Cleared on Jul 26, 2001 as substantially equivalent to K973741 (Augustine Medical, Inc., 1998) and 3 other predicates after a 28-day review. Its family tree reaches back 2 generations to 1977. 3 of the 18 devices in its family, counting itself, have a Class I recall. 13 later devices descend from it. It has been recalled once.

Decided
Jul 26, 2001
Review
28 days
Class
Class II
Product code
BSB
Recalls
1
Predicates
4

Its longest line of descent runs back 2 generations to K770232 (1977). 4 ancestors in all. 13 later devices descend from it, 2 citing it directly. 3 of the 18 devices in this family, counting this one, have a Class I recall.

Other ancestors, by year clearedDescendants, by year cleared 1998: 1 other ancestor, 1 with a Class I recall11991: 1 other ancestor2011: 1 descendant cleared2006: 1 descendant cleared, 1 with a Class I recall12012: 2 descendants cleared2024: 1 descendant cleared2016: 1 descendant cleared2023: 1 descendant cleared2019: 2 descendants cleared2013: 1 descendant cleared, 1 with a Class I recall12017: 1 descendant cleared2025: 1 descendant cleared2026: 1 descendant clearedK770232 · Blood/Fluid Warmer Model DW-1000A · Gorman Rupp Industries · 1977K984640 · Thermal Angel · Estill Medical Technologies, Inc. · 1999 · recalled19801990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 2 other ancestors, 1 with a Class I recall1 1 generation forward: 2 descendants, 1 with a Class I recall12 generations forward: 1 descendant3 generations forward: 5 descendants4 generations forward: 5 descendants, 1 with a Class I recall1 K984640 · Thermal Angel · Estill Medical Technologies, Inc. · 1999 · recalledK770232 · Blood/Fluid Warmer Model DW-1000A · Gorman Rupp Industries · 19770
  1. Root · 2 generations backK770232 Blood/Fluid Warmer Model DW-1000AGorman Rupp Industries · 1977
  2. 1 generation backK984640 Thermal AngelEstill Medical Technologies, Inc. · 1999 · Recalled
  3. This deviceK012031 Modification to Thermal AngelEstill Medical Technologies, Inc. · 2001
  4. Descendant · cites it directly · 12 of its ownK060537 Eflow IV Fluid Warmer, Model 100, Eflow Disposable Cartridge, Model…Enginivity, LLC · 2006 · Recalled (Class I)
  5. Descendant · 2 generations on · 10 of its ownK112902 Enflow IV Fluid WarmerVital Signs, Inc. · 2012
  6. Descendant · 3 generations on · 1 of its ownK232107 °M Warmer SystemMequ A/S · 2024
  7. Descendant · 3 generations on · 1 of its ownK211618 Fluido Compact Blood and Fluid Warming SystemThe Surgical Company International B.V. · 2023
  8. Descendant · 3 generations on · 1 of its ownK181775 Quantum Blood and IV Fluid Infusion WarmerLife Warmer, Inc. · 2019

Showing 5 of 13 descendants. See all descendants

Descendants cleared per year

2006: 12011: 12012: 22013: 12016: 12017: 12019: 22023: 12024: 12025: 12026: 1
2006high 2 (2012) · low 0 (2007)2026

Class I recalls in this family

Most influential descendants

Showing 5 of 13 · See all
  • K060537Eflow IV Fluid Warmer, Model 100, Eflow Disposable Cartridge, Model 200 and Eflow AC…Enginivity, LLC · 2006 · cites it directly12descendants
  • K112902Enflow IV Fluid WarmerVital Signs, Inc. · 2012 · 2 generations on10descendants
  • K232107°M Warmer SystemMequ A/S · 2024 · 3 generations on1descendant
  • K211618Fluido Compact Blood and Fluid Warming SystemThe Surgical Company International B.V. · 2023 · 3 generations on1descendant
  • K181775Quantum Blood and IV Fluid Infusion WarmerLife Warmer, Inc. · 2019 · 3 generations on1descendant
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K770232Blood/Fluid Warmer Model DW-1000AGorman Rupp Industries1977—
−1K984640Thermal AngelEstill Medical Technologies, Inc.19991
0 (this device)K012031Modification to Thermal AngelEstill Medical Technologies, Inc.2001—
+1K060537Eflow IV Fluid Warmer, Model 100, Eflow Disposable Cartridge, Model 200 and…Enginivity, LLC2006Class I
+2K112902Enflow IV Fluid WarmerVital Signs, Inc.2012—
+3K232107°M Warmer SystemMequ A/S2024—
+3K211618Fluido Compact Blood and Fluid Warming SystemThe Surgical Company International B.V.2023—
+3K181775Quantum Blood and IV Fluid Infusion WarmerLife Warmer, Inc.2019—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199110
199811

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200611
201110
201220
201311
201610
201710
201920
202310
202410
202510
202610
FIG. 1 — Lineage of K012031, 1977–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

3 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (4)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K973741Bair Hugger Blood/Fluid Warmer
Summary page 2
…Device and the Predigate Devices: The Thermal Angel™ model 200 Blood/Fiuid Warmar is substantially equivalent tc the Augustine Medical Bair Hugger ™ Blood/Fluld Warmer (K973741), the Baxter Thermacyl™ Blood/Fluid Warmer (K770232), the Levell Technologies, inc Hotline™ Fluid Warmer (K911383) and the Therma…
Augustine Medical, Inc.1998Class I
*K770232Blood/Fluid Warmer Model DW-1000A
Summary page 2
…™ model 200 Blood/Fiuid Warmar is substantially equivalent tc the Augustine Medical Bair Hugger ™ Blood/Fluld Warmer (K973741), the Baxter Thermacyl™ Blood/Fluid Warmer (K770232), the Levell Technologies, inc Hotline™ Fluid Warmer (K911383) and the Thermal Angel™ (K984640). Comparisons of technological fea…
Gorman Rupp Industries1977—
*K911383Hotline Fluid Warmer
Summary page 2
…the Augustine Medical Bair Hugger ™ Blood/Fluld Warmer (K973741), the Baxter Thermacyl™ Blood/Fluid Warmer (K770232), the Levell Technologies, inc Hotline™ Fluid Warmer (K911383) and the Thermal Angel™ (K984640). Comparisons of technological features are on the following page. Discussion of Nonclinical St…
Level 1 Technologies, Inc.199111
*K984640Thermal Angel
Summary page 1
…dicate Devices: Augustine Medical Bair Hugger™ Blood/Fluid Warmer, Levell Technologies, Inc Hotline™ Fluid Warmer, Baxter Thermacyl™ Blood/Fluid Warmer, Thermal Angei™ (K984640) Descriptiopn of Device: The Thermal Angel™ model 200 Blood/Fluid Warmer consists of a single unit that is placed between a sta…
Estill Medical Technologies, Inc.19991

Also cleared against K973741: 6 other devices →

What descends from it? (13)

See all 13

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K060537Eflow IV Fluid Warmer, Model 100, Eflow Disposable Cartridge, Model 200 and Eflow AC… Class IEnginivity, LLC200612
K103801Hypothermx Intravenous Fluid WarmerEmit Corporation20110

Has anything in its family been recalled? (3 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Jul 25, 2014Class IIZ-0101-2015Device DesignEstill has discovered that a fully discharged Ultra Battery 1 (TA-UB1) will reach 96.9% of its capacity during a 60 minute charging period. If you have a fully discharged Ultra Battery 1 (TA-UB1), in order to achieve a 100% of charge…

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K973741Bair Hugger Blood/Fluid WarmerAugustine Medical, Inc. · 1998 · Direct predicate · ◆ in the 1998 ancestors bar of FIG. 11 Class I recall
  • K060537Eflow IV Fluid Warmer, Model 100, Eflow Disposable Cartridge, Model 200 and Eflow AC Power Supply, Model 120Enginivity, LLC · 2006 · Cites it directly · ◆ in the 2006 descendants bar of FIG. 12 Class I recalls
  • K130867Enflow IV Fluid Warmer Insulated StrapVital Signs, Inc., A GE Healthcare Company · 2013 · 4 generations on · ◆ in the 2013 descendants bar of FIG. 12 Class I recalls

What does this lineage say?

  • The line of descent spans 24 years and passes through 2 companies; a new generation was cleared every 22.4 years on median.
  • 3 of the 4 ancestors have a recall of any class; 1 has a Class I recall.
  • Of its descendants, K060537 (Enginivity, LLC, 2006) has gone furthest, with 12 descendants of its own.
  • 6 other devices also cite its predicate K973741.

How does its category compare?

All BSB devices

BSB Warmer, Blood, Non-Electromagnetic Radiation: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · BSB

1in 2011

2009: 12011: 1
2007high 1 (2009) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · BSB

Too few BSB 510(k)s in any year since 2007 to give a median.

Recalls per year · BSB

1in 2014

2014: 1
2007high 1 (2014) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · BSB

197in 2025

2007: 42008: 52010: 62011: 352012: 42013: 52014: 102015: 112016: 662017: 292018: 362019: 1472020: 2162021: 3402022: 4472023: 2902024: 2822025: 197
2007high 447 (2022) · low 0 (2009)2025

MAUDE reports naming product code BSB, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—04
20080—05
20091—00
20100—06
20111—035
20120—04
20130—05
20140—110
20150—011
20160—066
20170—029
20180—036
20190—0147
20200—0216
20210—0340
20220—0447
20230—0290
20240—0282
20250—0197
20260—0—

What is it indicated for?

Thermal Angel™ model 200 Blood and Fluid Warmer is an in-line, intravenous blood and fluid warmer. Thermal Angel™ is indicated for use whenever introduction of normothermic, parenteral (intravenous or irrigation) fluids are desired or indicated, whether in field or clinical settings.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K012031: Modification to Thermal Angel.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K012031

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 30, 2026 (extraction version 2d9447fa9ea4)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026