510(k) Report

510(k) · Cleared

Cleared

Clip Partial Prosthesis-Titanium Dresden, Model 1002 250-257

K013573510(k) SpecialCleared Nov 9, 200111-day reviewClass II21 CFR 874.3450

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Heinz Kurz GmbH Medizintechnik · ETB Prosthesis, Partial Ossicular Replacement

Cleared on Nov 9, 2001 as substantially equivalent to K972492 (Heinz Kurz, 1997) after an 11-day review. Its family tree reaches back 1 generation to 1997. 2 later devices descend from it.

Decided
Nov 9, 2001
Review
11 days
Class
Class II
Product code
ETB
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to K972492 (1997). 2 later devices descend from it, 1 citing it directly.

Descendants, by year cleared 2025: 1 descendant cleared2026: 1 descendant clearedK972492 · Bell Prosthesis (Partial) · Heinz Kurz · 19971995200020052010201520202025
Descendants, by generation 1 generation forward: 1 descendant2 generations forward: 1 descendant K972492 · Bell Prosthesis (Partial) · Heinz Kurz · 19970
  1. Root · 1 generation backK972492 Bell Prosthesis (Partial)Heinz Kurz · 1997
  2. This deviceK013573 Clip Partial Prosthesis-Titanium Dresden, Model 1002 250-257Heinz Kurz GmbH Medizintechnik · 2001
  3. Descendant · cites it directly · 1 of its ownK241261 mCLIP Partial Prosthesis, mCLIP ARC Partial Prosthesis, mXACT…MED-EL Elektromedizinische Geräte GmbH · 2025
  4. Descendant · 2 generations on · 0 of its ownK260718 mGRIP Partial Prosthesis (0.75 mm) (58669);mGRIP Partial Prosthesis…MED-EL Elektromedizinische Geräte GmbH · 2026

Most influential descendants

Showing 2 of 2 · See all
  • K241261mCLIP Partial Prosthesis, mCLIP ARC Partial Prosthesis, mXACT Partial Prosthesis and…MED-EL Elektromedizinische Geräte GmbH · 2025 · cites it directly1descendant
  • K260718mGRIP Partial Prosthesis (0.75 mm) (58669);mGRIP Partial Prosthesis (1.00 mm)…MED-EL Elektromedizinische Geräte GmbH · 2026 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K972492Bell Prosthesis (Partial)Heinz Kurz1997—
0 (this device)K013573Clip Partial Prosthesis-Titanium Dresden, Model 1002 250-257Heinz Kurz GmbH Medizintechnik2001—
+1K241261mCLIP Partial Prosthesis, mCLIP ARC Partial Prosthesis, mXACT Partial…MED-EL Elektromedizinische Geräte GmbH2025—
+2K260718mGRIP Partial Prosthesis (0.75 mm) (58669);mGRIP Partial Prosthesis (1.00 mm)…MED-EL Elektromedizinische Geräte GmbH2026—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202510
202610
FIG. 1 — Lineage of K013573, 1997–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in ETB? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new ETB device

  1. #1 K241142 mAXIS Stapes Prosthesis, mLOOP Stapes…score 13.2 · 6 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K972492Bell Prosthesis (Partial)
Summary page 2
…Amtsgericht Tiibingen IBAN DE38 6406 1854 0070 150001 IRAN DF1RA417 0N 1901 4032 nn U=z N <. 2.6 Modification to Existing Device: [807.92 (a)(3)] N——” K 972492 Bell Prosthesis (Partial) | Heinz Kurz GmbH - Medizintechnik - Postfach 39 - D-72142 Dussfnigared 08/04/97 Heinz Kurz GmbH Medi…
Heinz Kurz1997—

Also cleared against K972492: 5 other devices →

What descends from it? (2)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K241261mCLIP Partial Prosthesis, mCLIP ARC Partial Prosthesis, mXACT Partial Prosthesis and…MED-EL Elektromedizinische Geräte GmbH20251

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has no recall.
  • Of its descendants, K241261 (MED-EL Elektromedizinische Geräte GmbH, 2025) has gone furthest, with 1 descendant of its own.
  • 5 other devices also cite its predicate K972492.

How does its category compare?

All ETB devices

ETB Prosthesis, Partial Ossicular Replacement: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · ETB

2in 2025

2008: 12013: 22025: 22026 (partial year): 2
2007high 2 (2013) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · ETB

Too few ETB 510(k)s in any year since 2007 to give a median.

Recalls per year · ETB

1so far in 2026, the most since 2007

2026 (partial year): 1
2007high 1 (2026) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · ETB

5in 2025

2008: 52010: 52011: 32012: 32013: 32014: 52015: 22016: 52017: 32019: 62020: 42021: 12022: 62023: 12024: 32025: 5
2007high 6 (2019) · low 0 (2007)2025

MAUDE reports naming product code ETB, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20081—05
20090—00
20100—05
20110—03
20120—03
20132—03
20140—05
20150—02
20160—05
20170—03
20180—00
20190—06
20200—04
20210—01
20220—06
20230—01
20240—03
20252—05
20262—1—

What is it indicated for?

Ossicle replacement in case of interrupted sound conducting chain in patients with intact, mobile stapes.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K013573: Clip Partial Prosthesis-Titanium Dresden, Model 1002 250-257.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K013573

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 30, 2026 (extraction version 2d9447fa9ea4)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026