510(k) · Cleared
ClearedRusch Memory Bag
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Rusch Intl. · GCJ Laparoscope, General & Plastic Surgery
Cleared on Feb 12, 2002 as substantially equivalent to K990912 (Mtp Medical Technical Promotion GmbH, 1999) and 1 other predicate after an 83-day review. Its family tree reaches back 1 generation to 1991. 1 later device descends from it.
- Decided
- Feb 12, 2002
- Review
- 83 days
- Class
- Class II
- Product code
- GCJ
- Recalls
- None
- Predicates
- 2
Its longest line of descent runs back 1 generation to K910914 (1991). 2 ancestors in all. 1 later device descends from it, 1 citing it directly.
Most influential descendants
Showing 1 of 1 · See all- K160801Well Lead Extraction BagWell Lead Medical Co., Ltd. · 2016 · cites it directly0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −1 | K910914 | Surgical Tissue Pouch | Cook Urological, Inc. | 1991 | 1 |
| 0 (this device) | K013872 | Rusch Memory Bag | Rusch Intl. | 2002 | — |
| +1 | K160801 | Well Lead Extraction Bag | Well Lead Medical Co., Ltd. | 2016 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1999 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2016 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in GCJ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new GCJ device
- #1 K214046 780 nm 1688 4K Camera System, 780 nm L11 LED…score 21.4 · 21 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (2)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K990912 | MTP Extraction BagSummary page 1…ly marketed device to which the submitter claims equivalence: The Riusch Memory Bag is substantially equivalent in design and materials to: L The MTP Extraction Bag - K990912 . The Cook LapSac - K910914 Page 2/2 K0[3%72 Description of the Device: The Rusch Memory Bag will be offered i… | 1999 |
| * | K910914 | Surgical Tissue PouchSummary page 1…the submitter claims equivalence: The Riusch Memory Bag is substantially equivalent in design and materials to: L The MTP Extraction Bag - K990912 . The Cook LapSac - K910914 Page 2/2 K0[3%72 Description of the Device: The Rusch Memory Bag will be offered in two (2) sizes 200ml bag wi… | 1991 |
What descends from it? (1)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K160801 | Well Lead Extraction Bag | 2016 | 0 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
How does its category compare?
All GCJ devicesGCJ Laparoscope, General & Plastic Surgery: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · GCJ
21in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · GCJ
108in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · GCJ
5in 2025
Class I (1 since 2007) Class II/III not classified
Adverse event reports per year · GCJ
5,860in 2025
MAUDE reports naming product code GCJ, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 18 | 42 | 12 | 1,639 |
| 2008 | 19 | 73 | 16 | 1,319 |
| 2009 | 21 | 85 | 6 | 1,995 |
| 2010 | 24 | 122 | 30 | 2,657 |
| 2011 | 15 | 113 | 9 | 2,133 |
| 2012 | 17 | 88 | 1 | 1,526 |
| 2013 | 15 | 93 | 7 (1) | 1,565 |
| 2014 | 19 | 90 | 2 | 1,714 |
| 2015 | 26 | 76 | 0 | 1,710 |
| 2016 | 27 | 99 | 5 | 2,080 |
| 2017 | 20 | 77 | 1 | 3,468 |
| 2018 | 21 | 88 | 1 | 2,562 |
| 2019 | 15 | 60 | 0 | 2,578 |
| 2020 | 28 | 61 | 0 | 2,618 |
| 2021 | 18 | 116 | 0 | 3,431 |
| 2022 | 20 | 103 | 1 | 3,945 |
| 2023 | 31 | 109 | 1 | 6,002 |
| 2024 | 29 | 90 | 0 | 6,047 |
| 2025 | 21 | 108 | 5 | 5,860 |
| 2026 | 26 | 122 | 1 | — |
What is it indicated for?
The Riisch Memory Bag 1is intended to be used for tissue extraction during laparoscopic procedures includind cholecystectomy, appendectomy, nephrectomy, laparoscopid colon surgery, thoracoscopy, lymphadenectomy, tubal pregnancy, intestinal resection, oophorocystectomy, hysterectomy and myomectomy.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K013872 · printed Nov 4, 2026
Cite this page
510(k) Report. “K013872: Rusch Memory Bag.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K013872
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 30, 2026 (extraction version 2d9447fa9ea4)
- Lineage and recalls computed Nov 3, 2026