510(k) Report

510(k) · Cleared

Cleared

Rusch Memory Bag

K013872510(k) TraditionalCleared Feb 12, 200283-day reviewClass II21 CFR 876.1500

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Rusch Intl. · GCJ Laparoscope, General & Plastic Surgery

Cleared on Feb 12, 2002 as substantially equivalent to K990912 (Mtp Medical Technical Promotion GmbH, 1999) and 1 other predicate after an 83-day review. Its family tree reaches back 1 generation to 1991. 1 later device descends from it.

Decided
Feb 12, 2002
Review
83 days
Class
Class II
Product code
GCJ
Recalls
None
Predicates
2

Its longest line of descent runs back 1 generation to K910914 (1991). 2 ancestors in all. 1 later device descends from it, 1 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 1999: 1 other ancestor2016: 1 descendant clearedK910914 · Surgical Tissue Pouch · Cook Urological, Inc. · 1991 · recalled1990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 1 other ancestor 1 generation forward: 1 descendant K910914 · Surgical Tissue Pouch · Cook Urological, Inc. · 1991 · recalled0
  1. Root · 1 generation backK910914 Surgical Tissue PouchCook Urological, Inc. · 1991 · Recalled
  2. This deviceK013872 Rusch Memory BagRusch Intl. · 2002
  3. Descendant · cites it directly · 0 of its ownK160801 Well Lead Extraction BagWell Lead Medical Co., Ltd. · 2016

Most influential descendants

Showing 1 of 1 · See all
  • K160801Well Lead Extraction BagWell Lead Medical Co., Ltd. · 2016 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K910914Surgical Tissue PouchCook Urological, Inc.19911
0 (this device)K013872Rusch Memory BagRusch Intl.2002—
+1K160801Well Lead Extraction BagWell Lead Medical Co., Ltd.2016—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199910

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201610
FIG. 1 — Lineage of K013872, 1991–2016Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in GCJ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GCJ device

  1. #1 K214046 780 nm 1688 4K Camera System, 780 nm L11 LED…score 21.4 · 21 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K990912MTP Extraction Bag
Summary page 1
…ly marketed device to which the submitter claims equivalence: The Riusch Memory Bag is substantially equivalent in design and materials to: L The MTP Extraction Bag - K990912 . The Cook LapSac - K910914 Page 2/2 K0[3%72 Description of the Device: The Rusch Memory Bag will be offered i…
Mtp Medical Technical Promotion GmbH1999—
*K910914Surgical Tissue Pouch
Summary page 1
…the submitter claims equivalence: The Riusch Memory Bag is substantially equivalent in design and materials to: L The MTP Extraction Bag - K990912 . The Cook LapSac - K910914 Page 2/2 K0[3%72 Description of the Device: The Rusch Memory Bag will be offered in two (2) sizes 200ml bag wi…
Cook Urological, Inc.19911

Also cleared against K990912: 1 other device →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K160801Well Lead Extraction BagWell Lead Medical Co., Ltd.20160

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • 1 of the 2 ancestors has a recall of any class.
  • Of its descendants, K160801 (Well Lead Medical Co., Ltd., 2016) has gone furthest, with 0 descendants of its own.
  • 1 other device also cites its predicate K990912.

How does its category compare?

All GCJ devices

GCJ Laparoscope, General & Plastic Surgery: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · GCJ

21in 2025

2007: 182008: 192009: 212010: 242011: 152012: 172013: 152014: 192015: 262016: 272017: 202018: 212019: 152020: 282021: 182022: 202023: 312024: 292025: 212026 (partial year): 26
2007high 31 (2023) · low 15 (2011)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GCJ

108in 2025

2007: 42 days median2008: 73 days median2009: 85 days median2010: 122 days median2011: 113 days median2012: 88 days median2013: 93 days median2014: 90 days median2015: 76 days median2016: 99 days median2017: 77 days median2018: 88 days median2019: 60 days median2020: 61 days median2021: 116 days median2022: 103 days median2023: 109 days median2024: 90 days median2025: 108 days median2026 (partial year): 122 days median
2007high 122 (2010) · low 42 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · GCJ

5in 2025

2007: 122008: 162009: 62010: 302011: 92012: 12013: 7, 1 Class I2014: 22016: 52017: 12018: 12022: 12023: 12025: 52026 (partial year): 1
2007high 30 (2010) · low 0 (2015)2026

Class I (1 since 2007) Class II/III not classified

Adverse event reports per year · GCJ

5,860in 2025

2007: 1,6392008: 1,3192009: 1,9952010: 2,6572011: 2,1332012: 1,5262013: 1,5652014: 1,7142015: 1,7102016: 2,0802017: 3,4682018: 2,5622019: 2,5782020: 2,6182021: 3,4312022: 3,9452023: 6,0022024: 6,0472025: 5,860
2007high 6,047 (2024) · low 1,319 (2008)2025

MAUDE reports naming product code GCJ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071842121,639
20081973161,319
2009218561,995
201024122302,657
20111511392,133
2012178811,526
201315937 (1)1,565
2014199021,714
2015267601,710
2016279952,080
2017207713,468
2018218812,562
2019156002,578
2020286102,618
20211811603,431
20222010313,945
20233110916,002
2024299006,047
20252110855,860
2026261221—

What is it indicated for?

The Riisch Memory Bag 1is intended to be used for tissue extraction during laparoscopic procedures includind cholecystectomy, appendectomy, nephrectomy, laparoscopid colon surgery, thoracoscopy, lymphadenectomy, tubal pregnancy, intestinal resection, oophorocystectomy, hysterectomy and myomectomy.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K013872: Rusch Memory Bag.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K013872

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 30, 2026 (extraction version 2d9447fa9ea4)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026