510(k) Report

510(k) · Cleared

Cleared

Modification to Geo Structure

K020048510(k) SpecialCleared Feb 6, 200230-day reviewClass II21 CFR 888.3060

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Interpore Cross Intl. · MQP Spinal Vertebral Body Replacement Device

Cleared on Feb 6, 2002 as substantially equivalent to K010530 (Interpore Cross Intl., 2001) after a 30-day review. Its family tree reaches back 1 generation to 2001. 2 of the 1,561 devices in its family, counting itself, have a Class I recall. 1,559 later devices descend from it.

Decided
Feb 6, 2002
Review
30 days
Class
Class II
Product code
MQP
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to K010530 (2001). 1,559 later devices descend from it, 3 citing it directly. 2 of the 1,561 devices in this family, counting this one, have a Class I recall.

Descendants, by year cleared 2003: 2 descendants cleared2005: 10 descendants cleared, 1 with a Class I recall12009: 10 descendants cleared2007: 9 descendants cleared2013: 53 descendants cleared2011: 39 descendants cleared2015: 73 descendants cleared2004: 2 descendants cleared2014: 79 descendants cleared2010: 17 descendants cleared2020: 107 descendants cleared2017: 115 descendants cleared2016: 93 descendants cleared2018: 111 descendants cleared2012: 42 descendants cleared2021: 105 descendants cleared, 1 with a Class I recall12023: 136 descendants cleared2006: 7 descendants cleared2008: 15 descendants cleared2022: 106 descendants cleared2026: 88 descendants cleared2025: 101 descendants cleared2019: 114 descendants cleared2024: 125 descendants clearedK010530 · Geo Structure · Interpore Cross Intl. · 2001200020052010201520202025
Descendants, by generation 1 generation forward: 3 descendants2 generations forward: 9 descendants3 generations forward: 31 descendants4 generations forward: 103 descendants5 generations forward: 215 descendants, 1 with a Class I recall16 generations forward: 289 descendants7 generations forward: 346 descendants8 generations forward: 220 descendants9 generations forward: 158 descendants, 1 with a Class I recall110 generations forward: 98 descendants11 generations forward: 49 descendants12 generations forward: 18 descendants13 generations forward: 11 descendants14 generations forward: 8 descendants15 generations forward: 1 descendant K010530 · Geo Structure · Interpore Cross Intl. · 20010+5+10+15
  1. Root · 1 generation backK010530 Geo StructureInterpore Cross Intl. · 2001
  2. This deviceK020048 Modification to Geo StructureInterpore Cross Intl. · 2002
  3. Descendant · cites it directly · 1,530 of its ownK031914 Spinal Concepts, Inc. Cadence and FortitudeSpinal Concepts, Inc. · 2003
  4. Descendant · 2 generations on · 1,528 of its ownK033517 Spinal Concepts Inc. Cadence and TraxisSpinal Concepts, Inc. · 2004 · Recalled
  5. Descendant · 3 generations on · 1,406 of its ownK062759 Paramount VBR SystemInnovative Spinal Technologies, Inc. · 2007
  6. Descendant · 4 generations on · 1,405 of its ownK072120 Paramount Intervertebral Body Fusion DeviceInnovative Spinal Technologies, Inc. · 2007
  7. Descendant · 5 generations on · 1,103 of its ownK073291 Capstone Spinal SystemMedtronic Sofamor Danek USA, Inc. · 2008

Showing 5 of 1,559 descendants. See all descendants

Descendants cleared per year

2003: 22004: 22005: 102006: 72007: 92008: 152009: 102010: 172011: 392012: 422013: 532014: 792015: 732016: 932017: 1152018: 1112019: 1142020: 1072021: 1052022: 1062023: 1362024: 1252025: 1012026: 88
2003high 136 (2023) · low 2 (2003)2026

Class I recalls in this family

Most influential descendants

Showing 5 of 1,559 · See all
  • K031914Spinal Concepts, Inc. Cadence and FortitudeSpinal Concepts, Inc. · 2003 · cites it directly1,530descendants
  • K033517Spinal Concepts Inc. Cadence and TraxisSpinal Concepts, Inc. · 2004 · 2 generations on1,528descendants
  • K062759Paramount VBR SystemInnovative Spinal Technologies, Inc. · 2007 · 3 generations on1,406descendants
  • K072120Paramount Intervertebral Body Fusion DeviceInnovative Spinal Technologies, Inc. · 2007 · 4 generations on1,405descendants
  • K073291Capstone Spinal SystemMedtronic Sofamor Danek USA, Inc. · 2008 · 5 generations on1,103descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K010530Geo StructureInterpore Cross Intl.2001—
0 (this device)K020048Modification to Geo StructureInterpore Cross Intl.2002—
+1K031914Spinal Concepts, Inc. Cadence and FortitudeSpinal Concepts, Inc.2003—
+2K033517Spinal Concepts Inc. Cadence and TraxisSpinal Concepts, Inc.20041
+3K062759Paramount VBR SystemInnovative Spinal Technologies, Inc.2007—
+4K072120Paramount Intervertebral Body Fusion DeviceInnovative Spinal Technologies, Inc.2007—
+5K073291Capstone Spinal SystemMedtronic Sofamor Danek USA, Inc.2008—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200320
200420
2005101
200670
200790
2008150
2009100
2010170
2011390
2012420
2013530
2014790
2015730
2016930
20171150
20181110
20191140
20201070
20211051
20221060
20231360
20241250
20251010
2026880
FIG. 1 — Lineage of K020048, 2001–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

2 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MQP device

  1. #1 K261810 Vertiwedge® Intraosseous Systemscore 18.1 · 22 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K010530Geo Structure
Summary page 1
…/Usual Name: Vertebral Body Replacement Product Classification: Class II Proprietary Name: GEO™ Structure PREDICATE DEVICE The predicate device is the GEO™ Structure (K010530). INDICATIONS-FOR-USE The GEO Structure is indicated for use in the thoracolumbar spine (i.e., T1 to L5) to replace a diseased…
Interpore Cross Intl.2001—

Also cleared against K010530: 9 other devices →

What descends from it? (1,559)

See all 1,559

3 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K031914Spinal Concepts, Inc. Cadence and FortitudeSpinal Concepts, Inc.20031,530
K031672Spinal Concepts, Inc. Infix SystemSpinal Concepts, Inc.2003862
K052170Seaspine VBR SystemSeaspine, Inc.200513

Has anything in its family been recalled? (2 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K051781Graftcage TLXOsteotech, Inc. · 2005 · 5 generations on · ◆ in the 2005 descendants bar of FIG. 11 Class I recall
  • K211616ExcelsiusHubGlobus Medical, Inc. · 2021 · 9 generations on · ◆ in the 2021 descendants bar of FIG. 11 Class I recall

What does this lineage say?

  • Its one ancestor has no recall.
  • Of its descendants, K031914 (Spinal Concepts, Inc., 2003) has gone furthest, with 1,530 descendants of its own.
  • 9 other devices also cite its predicate K010530.

How does its category compare?

All MQP devices

MQP Spinal Vertebral Body Replacement Device: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · MQP

4in 2024

2007: 302008: 172009: 112010: 62011: 82012: 72013: 32014: 52015: 82017: 92018: 62019: 82020: 32022: 12023: 12024: 42026 (partial year): 3
2007high 30 (2007) · low 0 (2016)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MQP

187in 2024

2007: 107 days median2008: 47 days median2009: 115 days median2010: 174 days median2011: 237 days median2012: 82 days median2013: 90 days median2014: 125 days median2015: 126 days median2017: 97 days median2018: 152 days median2019: 93 days median2020: 103 days median2024: 187 days median2026 (partial year): 102 days median
2007high 237 (2011) · low 47 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MQP

1in 2022

2007: 22009: 142010: 22011: 12012: 22020: 152022: 1
2007high 15 (2020) · low 0 (2008)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MQP

168in 2025

2007: 612008: 762009: 1112010: 1662011: 1212012: 1412013: 2072014: 2162015: 2582016: 1292017: 1412018: 1302019: 1172020: 1572021: 2082022: 1372023: 712024: 982025: 168
2007high 258 (2015) · low 61 (2007)2025

MAUDE reports naming product code MQP, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200730107261
20081747076
20091111514111
201061742166
201182371121
20127822141
20133900207
201451250216
201581260258
20160—0129
20179970141
201861520130
20198930117
2020310315157
20210—0208
20221—1137
20231—071
20244187098
20250—0168
202631020—

What is it indicated for?

The GEO Structure is indicated for use in the thoracolumbar spine (i.e., T1 to L5) to replace a diseased vertebral body resected or excised for the treatment of tumors in order to achieve anterior decompression of the spinal cord and neural tissues, and to restore the height of a collapsed vertebral body. The GEO Structure is also indicated for treating fractures of the thoracic and lumbar spine. The GEO Structure is designed to restore the biomechanical integrity of the anterior middle and posterior spinal column even in the absence of fusion for a prolonged period.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K020048: Modification to Geo Structure.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K020048

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026