510(k) · Cleared
ClearedModification to Altius Oct System
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Interpore Cross Intl. · KWP Appliance, Fixation, Spinal Interlaminal
Cleared on Dec 21, 2004 after a 29-day review. The FDA summary names no predicate by number. 142 later devices descend from it.
- Decided
- Dec 21, 2004
- Review
- 29 days
- Class
- Class II
- Product code
- KWP
- Recalls
- None
- Predicates
- 0
142 later devices descend from it, 10 citing it directly.
- This deviceK043229 Modification to Altius Oct SystemInterpore Cross Intl. · 2004
- Descendant · cites it directly · 102 of its ownK113593 Nextgen Altius Oct SystemBiomet Spine (Aka Ebi, LLC) · 2012
- Descendant · 2 generations on · 75 of its ownK123549 Polaris Spinal System - Ballista II Percutaneous Screw Placement…Biomet Spine (Aka Ebi, LLC) · 2013 · Recalled
- Descendant · 3 generations on · 70 of its ownK131615 Polaris Spinal SystemBiomet Spine (Aka Ebi, LLC) · 2013
- Descendant · 2 generations on · 67 of its ownK133746 Polaris Spinal SystemBiomet Spine (Aka Ebi, LLC) · 2014 · Recalled
- Descendant · 3 generations on · 30 of its ownK143248 Reform Pedicle Screw SystemPrecision Spine, Inc. · 2014
Showing 5 of 142 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 142 · See all- K113593Nextgen Altius Oct SystemBiomet Spine (Aka Ebi, LLC) · 2012 · cites it directly102descendants
- K123549Polaris Spinal System - Ballista II Percutaneous Screw Placement SystemBiomet Spine (Aka Ebi, LLC) · 2013 · 2 generations on75descendants
- K131615Polaris Spinal SystemBiomet Spine (Aka Ebi, LLC) · 2013 · 3 generations on70descendants
- K133746Polaris Spinal SystemBiomet Spine (Aka Ebi, LLC) · 2014 · 2 generations on67descendants
- K143248Reform Pedicle Screw SystemPrecision Spine, Inc. · 2014 · 3 generations on30descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| 0 (this device) | K043229 | Modification to Altius Oct System | Interpore Cross Intl. | 2004 | — |
| +1 | K113593 | Nextgen Altius Oct System | Biomet Spine (Aka Ebi, LLC) | 2012 | — |
| +2 | K123549 | Polaris Spinal System - Ballista II Percutaneous Screw Placement System | Biomet Spine (Aka Ebi, LLC) | 2013 | 2 |
| +3 | K131615 | Polaris Spinal System | Biomet Spine (Aka Ebi, LLC) | 2013 | — |
| +2 | K133746 | Polaris Spinal System | Biomet Spine (Aka Ebi, LLC) | 2014 | 1 |
| +3 | K143248 | Reform Pedicle Screw System | Precision Spine, Inc. | 2014 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2006 | 1 | 0 |
| 2007 | 2 | 0 |
| 2008 | 2 | 0 |
| 2009 | 2 | 0 |
| 2010 | 2 | 0 |
| 2011 | 3 | 0 |
| 2012 | 6 | 0 |
| 2013 | 5 | 0 |
| 2014 | 11 | 0 |
| 2015 | 13 | 0 |
| 2016 | 4 | 0 |
| 2017 | 9 | 0 |
| 2018 | 7 | 0 |
| 2019 | 5 | 0 |
| 2020 | 15 | 0 |
| 2021 | 7 | 0 |
| 2022 | 8 | 0 |
| 2023 | 12 | 0 |
| 2024 | 10 | 0 |
| 2025 | 9 | 0 |
| 2026 | 9 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in KWP? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
- Candidate predicates for a device like this, rankedin the report
- Recall history across each candidate’s familyin the report
What was it cleared against?
The FDA summary names no predicate by number.
What descends from it? (142)
See all 14210 later devices cite it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K113593 | Nextgen Altius Oct System | 2012 | 102 |
| K090343 | Sentinel Spinal System | 2009 | 21 |
| K062934 | Sierra | 2006 | 21 |
| K080526 | Sierra System | 2008 | 9 |
| K133698 | Synapse System | 2014 | 6 |
| K071905 | Posterior Cervicothoracic Spinal Fixation System (PCFS) | 2007 | 6 |
| K072729 | Sierra | 2008 | 5 |
| K061943 | Anatomica Posterior Cervical Fixation System | 2007 | 2 |
| K140734 | Nextgen Altius Oct System | 2014 | 0 |
| K141284 | Caspian Spinal System | 2014 | 0 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Of its descendants, K113593 (Biomet Spine (Aka Ebi, LLC), 2012) has gone furthest, with 102 descendants of its own.
How does its category compare?
All KWP devicesKWP Appliance, Fixation, Spinal Interlaminal: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · KWP
9in 2015
2026 to Oct 25, outlined.
Median 510(k) review, days · KWP
113in 2015
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · KWP
2in 2022
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · KWP
494in 2025
MAUDE reports naming product code KWP, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 14 | 96 | 2 | 210 |
| 2008 | 13 | 50 | 1 | 594 |
| 2009 | 12 | 89 | 23 | 682 |
| 2010 | 14 | 186 | 2 | 474 |
| 2011 | 12 | 67 | 6 | 792 |
| 2012 | 18 | 112 | 1 | 918 |
| 2013 | 12 | 99 | 3 | 1,090 |
| 2014 | 13 | 138 | 0 | 1,022 |
| 2015 | 9 | 113 | 1 | 1,348 |
| 2016 | 0 | — | 3 | 1,379 |
| 2017 | 0 | — | 0 | 864 |
| 2018 | 0 | — | 1 | 657 |
| 2019 | 0 | — | 2 | 518 |
| 2020 | 0 | — | 0 | 796 |
| 2021 | 0 | — | 0 | 525 |
| 2022 | 0 | — | 2 | 335 |
| 2023 | 0 | — | 0 | 332 |
| 2024 | 0 | — | 0 | 436 |
| 2025 | 0 | — | 0 | 494 |
| 2026 | 0 | — | 0 | — |
What is it indicated for?
When intended to promote fusion of the cervical spine and occipito-cervico-thoracic junction (occiput-T3), the Interpore Cross International Altius OCT System is indicated for:
* DDD (neck pain of discogenic origin with degeneration of the disc as confirmed by patient history and radiographic studies)
* Spondyloslisthesis
* Spinal stenosis
* Fracture/dislocation
* Atlantoaxial fracture with instability
* Occipitocervical dislocation
* Revision of previous cervical spine surgery
* Tumors
The occipital bone screws are limited to occipital fixation only.
The Altius OCT System can be linked to the Synergy Spinal System using the Transitional Rods and Rod Connectors from the Altius OCT System.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K043229 · printed Nov 3, 2026
Cite this page
510(k) Report. “K043229: Modification to Altius Oct System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 3, 2026. https://510kreport.com/device/K043229
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026