Diatek, Inc. · NFK Kit, Repair, Catheter, Hemodialysis

Cleared on May 9, 2002 as substantially equivalent to K010399 (Diatek, Inc., 2001) after a 90-day review. Its family tree reaches back 1 generation to 2001. 1 of the 3 devices in its family, counting itself, has a Class I recall. 1 later device descends from it. It has been recalled 2 times.

Decided
May 9, 2002
Review
90 days
Class
Class II
Product code
NFK
Recalls
2
Predicates
1

Its longest line of descent runs back 1 generation to K010399 (2001). 1 later device descends from it, 1 citing it directly. 1 of the 3 devices in this family, counting this one, has a Class I recall.

Descendants, by year cleared 2014: 1 descendant cleared, 1 with a Class I recall1K010399 · Diatek Cannon-Cath #CC2400, CC2800, CC3200, CC3600,CC5500. CC2400PC, CC2800PC, CC3200PC (32 CM), CC3200PC (36 CM) · Diatek, Inc. · 2001 · recalled200020052010201520202025
Descendants, by generation 1 generation forward: 1 descendant, 1 with a Class I recall1 K010399 · Diatek Cannon-Cath #CC2400, CC2800, CC3200, CC3600,CC5500. CC2400PC, CC2800PC, CC3200PC (32 CM), CC3200PC (36 CM) · Diatek, Inc. · 2001 · recalled0
  1. Root · 1 generation backK010399 Diatek Cannon-Cath #CC2400, CC2800, CC3200, CC3600,CC5500. CC2400PC…Diatek, Inc. · 2001 · Recalled
  2. This deviceK020430 Diatek Connector Assembly Replacement Kit (Cark)Diatek, Inc. · 2002
  3. Descendant · cites it directly · 0 of its ownK141051 Vectorflow; Antegrade Chronic Hemodialysis Catheter, Retrograde…Arrow International, Inc. · 2014 · Recalled (Class I)

Class I recalls in this family

Most influential descendants

Showing 1 of 1 · See all
  • K141051Vectorflow; Antegrade Chronic Hemodialysis Catheter, Retrograde Chronic Hemodialysis…Arrow International, Inc. · 2014 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K010399Diatek Cannon-Cath #CC2400, CC2800, CC3200, CC3600,CC5500. CC2400PC, CC2800PC…Diatek, Inc.20012
0 (this device)K020430Diatek Connector Assembly Replacement Kit (Cark)Diatek, Inc.2002—
+1K141051Vectorflow; Antegrade Chronic Hemodialysis Catheter, Retrograde Chronic…Arrow International, Inc.2014Class I

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201411
FIG. 1 — Lineage of K020430, 2001–2014Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K010399Diatek Cannon-Cath #CC2400, CC2800, CC3200, CC3600,CC5500. CC2400PC, CC2800PC, CC3200PC…
Summary page 1
…mponents in the Diatek Cannon-Cath product have been tested by both internal and outside laboratories for a range of criteria and found acceptable as submitted in 510(k) 010399 for the predicate device. o eIy, & %, £ ( DEPARTMENT OF HEALTH & HUMAN SERVICES Public Health Service o, R Food…
Diatek, Inc.20012

Also cleared against K010399: 2 other devices →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K141051Vectorflow; Antegrade Chronic Hemodialysis Catheter, Retrograde Chronic Hemodialysis… Class IArrow International, Inc.20140

Has anything in its family been recalled? (1 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Jul 6, 2020Class IIZ-2802-2020Incorrect or no expiration dateThe lidstock states the incorrect expiration date for the product. This issue could result in use of a device that is expired which could potentially lead to an increased risk of infection or other complications. Sterility…
Jul 6, 2020Class IIZ-2804-2020Incorrect or no expiration dateThe lidstock states the incorrect expiration date for the product. This issue could result in use of a device that is expired which could potentially lead to an increased risk of infection or other complications. Sterility…

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K141051Vectorflow; Antegrade Chronic Hemodialysis Catheter, Retrograde Chronic Hemodialysis Catheter, Retrograde…Arrow International, Inc. · 2014 · Cites it directly · ◆ in the 2014 descendants bar of FIG. 11 Class I recall

What does this lineage say?

  • Its one ancestor has a recall.
  • Of its descendants, K141051 (Arrow International, Inc., 2014) has gone furthest, with 0 descendants of its own.
  • 2 other devices also cite its predicate K010399.

How does its category compare?

All NFK devices

NFK Kit, Repair, Catheter, Hemodialysis: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · NFK

1in 2010

2009: 12010: 1
2007high 1 (2009) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · NFK

Too few NFK 510(k)s in any year since 2007 to give a median.

Recalls per year · NFK

No recall names NFK since 2007.

Adverse event reports per year · NFK

18in 2025

2007: 12009: 22010: 32011: 162012: 112013: 162014: 12015: 12016: 72017: 82018: 52019: 52020: 12022: 182023: 42024: 192025: 18
2007high 19 (2024) · low 0 (2008)2025

MAUDE reports naming product code NFK, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—01
20080—00
20091—02
20101—03
20110—016
20120—011
20130—016
20140—01
20150—01
20160—07
20170—08
20180—05
20190—05
20200—01
20210—00
20220—018
20230—04
20240—019
20250—018
20260—0—

What is it indicated for?

The Diatek Connector Assembly Replacement Kit is to be used for replacing the original connector assembly on a Diatek Cannon-Cath Dialysis Catheter if the connector assembly becomes damaged or dysfunctional. This prevents the patient from requiring additional surgery for catheter removal and replacement.

The Connector Assembly Replacement Kit is intended for use in any patient who has a previously implanted Diatek Cannon-Cath Dialysis Catheter implanted.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K020430: Diatek Connector Assembly Replacement Kit (Cark).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K020430

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026