510(k) Report

510(k) · Cleared

Recalled · Class II · 2012

Advantage Workstation 4.1

K020483510(k) TraditionalCleared Feb 28, 200215-day reviewClass II21 CFR 892.2050Recalls 2

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

GE Medical Systems · LLZ System, Image Processing, Radiological

Cleared on Feb 28, 2002 as substantially equivalent to K960613 (GE Medical Systems, 1996) after a 15-day review. Its family tree reaches back 2 generations to 1991. 1 of the 876 devices in its family, counting itself, has a Class I recall. 872 later devices descend from it. It has been recalled 2 times.

Decided
Feb 28, 2002
Review
15 days
Class
Class II
Product code
LLZ
Recalls
2
Predicates
1

Its longest line of descent runs back 2 generations to K913770 (1991). 3 ancestors in all. 872 later devices descend from it, 5 citing it directly. 1 of the 876 devices in this family, counting this one, has a Class I recall.

Other ancestors, by year clearedDescendants, by year cleared 1994: 1 other ancestor2003: 3 descendants cleared2019: 46 descendants cleared2005: 12 descendants cleared2002: 1 descendant cleared2004: 9 descendants cleared2021: 63 descendants cleared2006: 12 descendants cleared2009: 19 descendants cleared2007: 13 descendants cleared2008: 14 descendants cleared2011: 17 descendants cleared2015: 36 descendants cleared2014: 33 descendants cleared2012: 26 descendants cleared2020: 53 descendants cleared2010: 9 descendants cleared2016: 37 descendants cleared2022: 63 descendants cleared2013: 20 descendants cleared2017: 45 descendants cleared2018: 59 descendants cleared2024: 71 descendants cleared2023: 57 descendants cleared2025: 87 descendants cleared, 1 with a Class I recall12026: 67 descendants clearedK913770 · Advantage V.S. CT/MR Rad Diagnostic Workstation · General Electric Co. · 1991K960613 · GE Advantage Windows Review Workstation · GE Medical Systems · 19961990200020102020
Other ancestors, by generationDescendants, by generation 2 generations back: 1 other ancestor 1 generation forward: 5 descendants2 generations forward: 26 descendants3 generations forward: 58 descendants4 generations forward: 67 descendants5 generations forward: 98 descendants6 generations forward: 115 descendants7 generations forward: 109 descendants8 generations forward: 106 descendants9 generations forward: 84 descendants, 1 with a Class I recall110 generations forward: 61 descendants11 generations forward: 45 descendants12 generations forward: 33 descendants13 generations forward: 23 descendants14 generations forward: 22 descendants15 generations forward: 12 descendants16 generations forward: 5 descendants17 generations forward: 2 descendants18 generations forward: 1 descendant K960613 · GE Advantage Windows Review Workstation · GE Medical Systems · 1996K913770 · Advantage V.S. CT/MR Rad Diagnostic Workstation · General Electric Co. · 19910+5+10+15
  1. Root · 2 generations backK913770 Advantage V.S. CT/MR Rad Diagnostic WorkstationGeneral Electric Co. · 1991
  2. 1 generation backK960613 GE Advantage Windows Review WorkstationGE Medical Systems · 1996
  3. This deviceK020483 Advantage Workstation 4.1GE Medical Systems · 2002
  4. Descendant · cites it directly · 637 of its ownK033400 Seno AdvantageGe Medical Systems W-400 · 2003 · Recalled
  5. Descendant · 2 generations on · 324 of its ownK043415 Centricity Pacs SystemGe Medical Systems Information Technologies · 2005 · Recalled
  6. Descendant · 3 generations on · 287 of its ownK071964 Mim 4.1 (Seastar)Mimvista Corp. · 2007 · Recalled
  7. Descendant · 2 generations on · 263 of its ownK043216 Cadstream Version 4.0Confirma, Inc. · 2005
  8. Descendant · 4 generations on · 200 of its ownK091373 Syngo TruedSiemens Medical Solutions USA, Inc. · 2009

Showing 5 of 872 descendants. See all descendants

Descendants cleared per year

2002: 12003: 32004: 92005: 122006: 122007: 132008: 142009: 192010: 92011: 172012: 262013: 202014: 332015: 362016: 372017: 452018: 592019: 462020: 532021: 632022: 632023: 572024: 712025: 872026: 67
2002high 87 (2025) · low 1 (2002)2026

Class I recalls in this family

Most influential descendants

Showing 5 of 872 · See all
  • K033400Seno AdvantageGe Medical Systems W-400 · 2003 · cites it directly637descendants
  • K043415Centricity Pacs SystemGe Medical Systems Information Technologies · 2005 · 2 generations on324descendants
  • K071964Mim 4.1 (Seastar)Mimvista Corp. · 2007 · 3 generations on287descendants
  • K043216Cadstream Version 4.0Confirma, Inc. · 2005 · 2 generations on263descendants
  • K091373Syngo TruedSiemens Medical Solutions USA, Inc. · 2009 · 4 generations on200descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K913770Advantage V.S. CT/MR Rad Diagnostic WorkstationGeneral Electric Co.1991—
−1K960613GE Advantage Windows Review WorkstationGE Medical Systems1996—
0 (this device)K020483Advantage Workstation 4.1GE Medical Systems2002—
+1K033400Seno AdvantageGe Medical Systems W-40020036
+2K043415Centricity Pacs SystemGe Medical Systems Information Technologies200523
+3K071964Mim 4.1 (Seastar)Mimvista Corp.20072
+2K043216Cadstream Version 4.0Confirma, Inc.2005—
+4K091373Syngo TruedSiemens Medical Solutions USA, Inc.2009—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199410

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200210
200330
200490
2005120
2006120
2007130
2008140
2009190
201090
2011170
2012260
2013200
2014330
2015360
2016370
2017450
2018590
2019460
2020530
2021630
2022630
2023570
2024710
2025871
2026670
FIG. 1 — Lineage of K020483, 1991–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LLZ device

  1. #1 K230955 syngo Application Softwarescore 21.5 · 11 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K960613GE Advantage Windows Review Workstation
Summary page 1
…Workstation is substantially equivalent to the devices listed below: Model: Advantage Windows Review Workstation Manufacturer: General Electric Medical Systems 510 (k): K960613 Device Description : Advantage Workstation 4.1 is a review station, which allows easy selection, review, processing and filming…
GE Medical Systems1996—

Also cleared against K960613: 5 other devices →

What descends from it? (872)

See all 872

5 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K033400Seno AdvantageGe Medical Systems W-4002003637
K023003Imagechecker-CT WorkstationR2 Technology, Inc.2002177
K032748VITREA2, Version 3.4 Medical Image Processing SoftwareVital Images, Inc.2003170
K052995Advantage Workstation 4.3.GE Healthcare2005113
K183193MREplus+ SoftwareResoundant, Inc.20190

Has anything in its family been recalled? (1 Class I)

Recalls of this device

DateClassRecallRoot causeReason
May 24, 2012Class IIZ-2203-2012Software designGE Healthcare is informing you of incorrect measurements when using the Aorta analysis protocol or customized protocols. Until a new software version is installed they are asking you not to use the aorta analysis protocol or the…
Sep 10, 2007Not classifiedZ-0265-2008Software designAortic Length over-estimated: incorrect measurements when using the Aorta analysis protocol or customized protocols. Until a new software version is installed the aorta analysis protocol or the customized protocols for an aneurysm should…

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K250443MAGNETOM Avanto Fit; MAGNETOM Skyra Fit; MAGNETOM Sola Fit; MAGNETOM Viato.MobileSiemens Healthcare GmbH · 2025 · 9 generations on · ◆ in the 2025 descendants bar of FIG. 12 Class I recalls

What does this lineage say?

  • The line of descent spans 11 years and passes through 2 companies; a new generation was cleared every 5.8 years on median.
  • None of the 3 ancestors has a recall.
  • Of its descendants, K033400 (Ge Medical Systems W-400, 2003) has gone furthest, with 637 descendants of its own.
  • 5 other devices also cite its predicate K960613.

How does its category compare?

All LLZ devices

LLZ System, Image Processing, Radiological: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · LLZ

58in 2025

2007: 762008: 942009: 702010: 512011: 1062012: 822013: 952014: 782015: 642016: 822017: 782018: 1042019: 742020: 812021: 832022: 652023: 872024: 622025: 582026 (partial year): 45
2007high 106 (2011) · low 51 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LLZ

173in 2025

2007: 36 days median2008: 52 days median2009: 62 days median2010: 98 days median2011: 79 days median2012: 87 days median2013: 84 days median2014: 89 days median2015: 90 days median2016: 90 days median2017: 107 days median2018: 105 days median2019: 107 days median2020: 115 days median2021: 116 days median2022: 137 days median2023: 157 days median2024: 131 days median2025: 173 days median2026 (partial year): 110 days median
2007high 173 (2025) · low 36 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · LLZ

11in 2025

2007: 202008: 322009: 212010: 172011: 302012: 122013: 642014: 62015: 162016: 122017: 52018: 72019: 22020: 62021: 32022: 42023: 82024: 62025: 112026 (partial year): 14
2007high 64 (2013) · low 2 (2019)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · LLZ

116in 2025

2007: 1522008: 1542009: 1452010: 1452011: 4542012: 2662013: 1,1302014: 15,6312015: 2112016: 2902017: 1042018: 722019: 882020: 822021: 702022: 282023: 262024: 422025: 116
2007high 15,631 (2014) · low 26 (2023)2025

MAUDE reports naming product code LLZ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007763620152
2008945232154
2009706221145
2010519817145
20111067930454
2012828712266
20139584641,130
20147889615,631
2015649016211
2016829012290
2017781075104
2018104105772
201974107288
202081115682
202183116370
202265137428
202387157826
202462131642
20255817311116
20264511014—

What is it indicated for?

The Advantage Workstation 4.1 is a review station, which allows easy selection, review, processing, filming and media interchange of multi-modality images from a variety of diagnostic imaging systems. When interpreted by a trained physician, filmed images may be used as an element for diagnosis.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K020483: Advantage Workstation 4.1.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K020483

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026