510(k) Report

510(k) · Cleared

Recalled · Class II · 2026

Centricity Pacs System

K043415510(k) TraditionalCleared Jan 21, 200539-day reviewClass II21 CFR 892.2050Recalls 23

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Ge Medical Systems Information Technologies · LLZ System, Image Processing, Radiological

Cleared on Jan 21, 2005 as substantially equivalent to K023557 (GE Medical Systems, 2002) and 1 other predicate after a 39-day review. Its family tree reaches back 4 generations to 1991. 1 of the 333 devices in its family, counting itself, has a Class I recall. 324 later devices descend from it. It has been recalled 23 times.

Decided
Jan 21, 2005
Review
39 days
Class
Class II
Product code
LLZ
Recalls
23
Predicates
2

Its longest line of descent runs back 4 generations to K913770 (1991). 8 ancestors in all. 324 later devices descend from it, 11 citing it directly. 1 of the 333 devices in this family, counting this one, has a Class I recall.

Other ancestors, by year clearedDescendants, by year cleared 2002: 1 other ancestor1998: 1 other ancestor1992: 1 other ancestor1994: 1 other ancestor2011: 8 descendants cleared2006: 3 descendants cleared2007: 3 descendants cleared2008: 3 descendants cleared2005: 2 descendants cleared2014: 7 descendants cleared2009: 2 descendants cleared2012: 6 descendants cleared2021: 22 descendants cleared2013: 6 descendants cleared2010: 5 descendants cleared2019: 21 descendants cleared2018: 25 descendants cleared2016: 13 descendants cleared2024: 27 descendants cleared2017: 13 descendants cleared2022: 28 descendants cleared2015: 8 descendants cleared2025: 36 descendants cleared, 1 with a Class I recall12020: 25 descendants cleared2023: 25 descendants cleared2026: 36 descendants clearedK913770 · Advantage V.S. CT/MR Rad Diagnostic Workstation · General Electric Co. · 1991K960613 · GE Advantage Windows Review Workstation · GE Medical Systems · 1996K020483 · Advantage Workstation 4.1 · GE Medical Systems · 2002 · recalledK033400 · Seno Advantage · Ge Medical Systems W-400 · 2003 · recalled1990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 1 other ancestor2 generations back: 2 other ancestors4 generations back: 1 other ancestor 1 generation forward: 11 descendants2 generations forward: 19 descendants3 generations forward: 36 descendants4 generations forward: 45 descendants5 generations forward: 46 descendants6 generations forward: 49 descendants7 generations forward: 37 descendants, 1 with a Class I recall18 generations forward: 27 descendants9 generations forward: 20 descendants10 generations forward: 12 descendants11 generations forward: 9 descendants12 generations forward: 6 descendants13 generations forward: 3 descendants14 generations forward: 2 descendants15 generations forward: 1 descendant16 generations forward: 1 descendant K033400 · Seno Advantage · Ge Medical Systems W-400 · 2003 · recalledK020483 · Advantage Workstation 4.1 · GE Medical Systems · 2002 · recalledK960613 · GE Advantage Windows Review Workstation · GE Medical Systems · 1996K913770 · Advantage V.S. CT/MR Rad Diagnostic Workstation · General Electric Co. · 19910+5+10+15
  1. Root · 4 generations backK913770 Advantage V.S. CT/MR Rad Diagnostic WorkstationGeneral Electric Co. · 1991
  2. 3 generations backK960613 GE Advantage Windows Review WorkstationGE Medical Systems · 1996
  3. 2 generations backK020483 Advantage Workstation 4.1GE Medical Systems · 2002 · Recalled
  4. 1 generation backK033400 Seno AdvantageGe Medical Systems W-400 · 2003 · Recalled
  5. This deviceK043415 Centricity Pacs SystemGe Medical Systems Information Technologies · 2005
  6. Descendant · cites it directly · 287 of its ownK071964 Mim 4.1 (Seastar)Mimvista Corp. · 2007 · Recalled
  7. Descendant · 2 generations on · 200 of its ownK091373 Syngo TruedSiemens Medical Solutions USA, Inc. · 2009
  8. Descendant · 2 generations on · 79 of its ownK103576 Mim 5.2 (Brachy)Mim Software, Inc. · 2011
  9. Descendant · 3 generations on · 76 of its ownK101749 Syngo Trued SoftwareSiemens Medical Solutions · 2010
  10. Descendant · 2 generations on · 70 of its ownK101228 Mirada XDMirada Medical, Ltd. · 2010

Showing 5 of 324 descendants. See all descendants

Descendants cleared per year

2005: 22006: 32007: 32008: 32009: 22010: 52011: 82012: 62013: 62014: 72015: 82016: 132017: 132018: 252019: 212020: 252021: 222022: 282023: 252024: 272025: 362026: 36
2005high 36 (2025) · low 2 (2005)2026

Class I recalls in this family

Most influential descendants

Showing 5 of 324 · See all
  • K071964Mim 4.1 (Seastar)Mimvista Corp. · 2007 · cites it directly287descendants
  • K091373Syngo TruedSiemens Medical Solutions USA, Inc. · 2009 · 2 generations on200descendants
  • K103576Mim 5.2 (Brachy)Mim Software, Inc. · 2011 · 2 generations on79descendants
  • K101749Syngo Trued SoftwareSiemens Medical Solutions · 2010 · 3 generations on76descendants
  • K101228Mirada XDMirada Medical, Ltd. · 2010 · 2 generations on70descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K913770Advantage V.S. CT/MR Rad Diagnostic WorkstationGeneral Electric Co.1991—
−3K960613GE Advantage Windows Review WorkstationGE Medical Systems1996—
−2K020483Advantage Workstation 4.1GE Medical Systems20022
−1K033400Seno AdvantageGe Medical Systems W-40020036
0 (this device)K043415Centricity Pacs SystemGe Medical Systems Information Technologies2005—
+1K071964Mim 4.1 (Seastar)Mimvista Corp.20072
+2K091373Syngo TruedSiemens Medical Solutions USA, Inc.2009—
+2K103576Mim 5.2 (Brachy)Mim Software, Inc.2011—
+3K101749Syngo Trued SoftwareSiemens Medical Solutions2010—
+2K101228Mirada XDMirada Medical, Ltd.2010—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199210
199410
199810
200210

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200520
200630
200730
200830
200920
201050
201180
201260
201360
201470
201580
2016130
2017130
2018250
2019210
2020250
2021220
2022280
2023250
2024270
2025361
2026360
FIG. 1 — Lineage of K043415, 1991–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LLZ device

  1. #1 K230955 syngo Application Softwarescore 21.5 · 11 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K023557Centricity Pacs Plus
Summary page 1
…ure Archiving and Communications Systems and Workstation Classification Names: 21 CFR 892.2050 System, Image Processing, Radiological Predicate Device: K023557: Centricity™ PACS Plus K033400: Seno Advantage Device Description: The Centricity™ PACS…
GE Medical Systems2002—
*K033400Seno Advantage
Summary page 1
…Classification Names: 21 CFR 892.2050 System, Image Processing, Radiological Predicate Device: K023557: Centricity™ PACS Plus K033400: Seno Advantage Device Description: The Centricity™ PACS include the following major components:…
Ge Medical Systems W-40020036

Also cleared against K023557: 5 other devices →

What descends from it? (324)

See all 324

11 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K071964Mim 4.1 (Seastar)Mimvista Corp.2007287
K083018Centricity Pacs Web DiagnosticGe Healthcare Dynamic Imaging Solutions20089
K063267Isite Pacs, V 4. XStentor Inc., A Philips Medical Systems Co.20068
K110875Centricity PacsGE Healthcare20116
K053458WEB1000Agfa Corp.20055
K112096ImagelinkComputer Programs and Systems, Inc.20110
K081948Raypax SystemRaypax, Inc.20080
K071492FirstviewRiverain Medical Group,Llc20070
K062757Xeron PacsXeron Healthcare Corp.20060
K061372Centricity AW Suite OptionGe Healthcare Information Technologies20060

Has anything in its family been recalled? (1 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Jul 31, 2026Class IIZ-3171-2026Under Investigation by firmUnder certain conditions historical imaging data migrated from a legacy system may become incorrectly associated with a different patient. If this occurs, studies or images may be displayed under the wrong patient record, which could lead…
Jul 31, 2026Class IIZ-3166-2026Under Investigation by firmUnder certain conditions historical imaging data migrated from a legacy system may become incorrectly associated with a different patient. If this occurs, studies or images may be displayed under the wrong patient record, which could lead…
Jul 31, 2026Class IIZ-3169-2026Under Investigation by firmUnder certain conditions historical imaging data migrated from a legacy system may become incorrectly associated with a different patient. If this occurs, studies or images may be displayed under the wrong patient record, which could lead…
Jul 31, 2026Class IIZ-3167-2026Under Investigation by firmUnder certain conditions historical imaging data migrated from a legacy system may become incorrectly associated with a different patient. If this occurs, studies or images may be displayed under the wrong patient record, which could lead…
Jul 31, 2026Class IIZ-3170-2026Under Investigation by firmUnder certain conditions historical imaging data migrated from a legacy system may become incorrectly associated with a different patient. If this occurs, studies or images may be displayed under the wrong patient record, which could lead…
Jul 31, 2026Class IIZ-3168-2026Under Investigation by firmUnder certain conditions historical imaging data migrated from a legacy system may become incorrectly associated with a different patient. If this occurs, studies or images may be displayed under the wrong patient record, which could lead…
Aug 5, 2024Class IIZ-3214-2024Device DesignGE HealthCare has become aware of an issue where image storage is not possible when Centricity PACS reaches the maximum number of unique image identifiers (Ckeys). If this occurs, it can result in acquisition of a partial study.
Apr 3, 2014Class IIZ-1665-2014Software designIt has been identified that in a reject image workflow where multiple studies are simultaneously opened on the Centricity PACS RA1000 workstation and images are rejected from the active displayed study, images for the previously displayed…
Jun 11, 2013Class IIZ-0116-2014Software designGE has recently become aware of potential issues due to out of context issues associated with specific workflows of the Centricity PACS RA1000 workstation. These issues are as follows: 1) In Centricity RIS-IC, and a RIS-Driven…
Feb 18, 2013Class IIZ-1214-2015Software designUsing Merge Exam in single Study Mode may result in Missing Study Record (Cannot Display Exam, Send Exam, etc). Exam merge in Single Study Mode may fail on…
Nov 15, 2012Class IIZ-2579-2016Software designWhile merging exams in a test instance, merges carry forward in the production system, when the middle tier is configured to the wrong IP address of the Centricity Exam Manager. When a current and historical exam are opened at the same…
Sep 15, 2012Class IIZ-0731-2014Software designThere is a potential loss of image(s) associated with the Centricity to Centricity (C2C) exam transfer module of Centricity PACS System versions 3.X and higher and 4.X and higher when transferring from the source to a destination server.…
Sep 25, 2009Not classifiedZ-0456-2010Software designThere are potential safety issues, including misdiagnosis or delay in treatment, associated with the use of GE Centricity PACS RA1000 Workstation software that may impact patient safety.
Apr 3, 2009Not classifiedZ-1549-2009Software designThere is a potential safety issue associated with the use of GE Centricity PACS software related to configuration of DICOM query retrieval with rejected images.
Mar 24, 2009Not classifiedZ-1543-2009Software designSoftware anomalies may allow the image orientation to be misinterpreted, posing a potential patient safety issue.
Jan 12, 2009Not classifiedZ-0969-2009Software designIf a user site created a custom default display protocol (DDP) to display the current exam versus the historical exam and the user-defined DDP fails, the system displays the exams using a GE default hanging protocol. This may create a…
Dec 12, 2008Not classifiedZ-0836-2009Software designThere is a potential patient safety issue involving the use of the F12 keyboard Approve & Complete function. The issue may cause erroneous information to be added to a report when trying to approve and complete it.
Nov 21, 2008Not classifiedZ-0928-2009Software designThere is a potential patient safety issue involving patient jacket content, which may result in unintended historical image(s) being displayed.
Nov 20, 2008Not classifiedZ-0970-2009Software designUnread exams may inadvertently get marked as dictated in PACS workstation when the user signs off the report in Talkstation and opens the next exam.
Sep 25, 2008Not classifiedZ-0460-2009Software designSoftware anomalies result in patient safety issues involving patient jacket content intermittently becoming unintentionally out of synchronization with the images being displayed, and involving Default Display Protocols (DDPs) which are…
May 6, 2008Not classifiedZ-1826-2008Software designA software anomaly results in incorrect study date and time information being displayed in the report screen and title, which may result in a potential patient misdiagnosis.
Dec 28, 2007Not classifiedZ-1104-2008Software designReport missing characters: Four special characters, when entered into the exam notes, are not transferred to the preview panel or hard copy printout (greater than [>], less than [<], quotation mark ["], and apostrophe [']). This may not…
Jan 12, 2007Not classifiedZ-0373-2007OtherThe Centricity PACS RA1000 Workstation Software may manifest certain mammography image display problems only if the images were acquired through GE Senographe versions 2000D, DS or Essential.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K250443MAGNETOM Avanto Fit; MAGNETOM Skyra Fit; MAGNETOM Sola Fit; MAGNETOM Viato.MobileSiemens Healthcare GmbH · 2025 · 7 generations on · ◆ in the 2025 descendants bar of FIG. 12 Class I recalls

What does this lineage say?

  • The line of descent spans 14 years and passes through 4 companies; a new generation was cleared every 4.3 years on median.
  • 2 of the 8 ancestors have a recall of any class.
  • Of its descendants, K071964 (Mimvista Corp., 2007) has gone furthest, with 287 descendants of its own.
  • 5 other devices also cite its predicate K023557.

How does its category compare?

All LLZ devices

LLZ System, Image Processing, Radiological: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · LLZ

58in 2025

2007: 762008: 942009: 702010: 512011: 1062012: 822013: 952014: 782015: 642016: 822017: 782018: 1042019: 742020: 812021: 832022: 652023: 872024: 622025: 582026 (partial year): 45
2007high 106 (2011) · low 51 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LLZ

173in 2025

2007: 36 days median2008: 52 days median2009: 62 days median2010: 98 days median2011: 79 days median2012: 87 days median2013: 84 days median2014: 89 days median2015: 90 days median2016: 90 days median2017: 107 days median2018: 105 days median2019: 107 days median2020: 115 days median2021: 116 days median2022: 137 days median2023: 157 days median2024: 131 days median2025: 173 days median2026 (partial year): 110 days median
2007high 173 (2025) · low 36 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · LLZ

11in 2025

2007: 202008: 322009: 212010: 172011: 302012: 122013: 642014: 62015: 162016: 122017: 52018: 72019: 22020: 62021: 32022: 42023: 82024: 62025: 112026 (partial year): 14
2007high 64 (2013) · low 2 (2019)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · LLZ

116in 2025

2007: 1522008: 1542009: 1452010: 1452011: 4542012: 2662013: 1,1302014: 15,6312015: 2112016: 2902017: 1042018: 722019: 882020: 822021: 702022: 282023: 262024: 422025: 116
2007high 15,631 (2014) · low 26 (2023)2025

MAUDE reports naming product code LLZ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007763620152
2008945232154
2009706221145
2010519817145
20111067930454
2012828712266
20139584641,130
20147889615,631
2015649016211
2016829012290
2017781075104
2018104105772
201974107288
202081115682
202183116370
202265137428
202387157826
202462131642
20255817311116
20264511014—

What is it indicated for?

The Centricity TM PACS provides scaleable image, data management and storage solutions for medical imaging. The system is intended for the storage, reading, diagnostic review, analysis, annotation, distribution, printing, editing, and processing of digital images and data acquired from diagnostic imaging devices such as Computed Tomography (CT), Magnetic Resonance (MR), Computed Radiography (CR), Digital X-Ray (DX), Digital Mammography (MG), Ultrasound…

Read the full statement (337 words)

The Centricity TM PACS provides scaleable image, data management and storage solutions for medical imaging. The system is intended for the storage, reading, diagnostic review, analysis, annotation, distribution, printing, editing, and processing of digital images and data acquired from diagnostic imaging devices such as Computed Tomography (CT), Magnetic Resonance (MR), Computed Radiography (CR), Digital X-Ray (DX), Digital Mammography (MG), Ultrasound (US), Nuclear Medicine (NM), Positron Emission Tomography (PET), X-Ray Angiography (XA), and any other DICOM devices.

The Centricity TM PACS Workstation is intended for use as a primary diagnostic and analysis tool for diagnostic images by trained healthcare professionals, including radiologists, physicians, technologists, clinicians and nurses. It is also intended for use as a clinical review workstation throughout the healthcare facility. The workstation interface provides the user with a means to display, manipulate, archive, print, and export images when connected with the Centricity TM PACS infrastructure.

To be viewed for primary interpretation, the digital mammography images must be acquired from an FDA approved Full Field Digital Mammography (FFDM) device for primary interpretation. Furthermore, the FFDM must be able to provide, to the Centricity TM PACS, a viewable DICOM 'for presentation' mammography image as approved by the FDA for primary interpretation. Images that are printed to film must be printed using a FDA approved printer for the diagnosis of digital mammography images.

To be viewed for primary diagnosis, digital mammography images must be viewed on a display system that has been cleared by the FDA for the diagnosis of digital mammography images.

The Web client software allows the user to display and manipulate images stored in the Centricity TM PACS or other DICOM archive device including the Centricity TM Enterprise Archive. The Centricity TM Web is not intended for primary diagnosis.

The Centricity TM Infrastructure provides for the system's database management, storage, printing, HL-7 interfacing, and all DICOM services such as Store, Print, Query/ Retrieve, Send, etc.

It is the user's responsibility to ensure quality, ambient light conditions and image compression ratios are consistent with the clinical application.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K043415: Centricity Pacs System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K043415

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026