510(k) · Cleared
ClearedFusion 7D
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Mirada Solutions, Ltd. · LLZ System, Image Processing, Radiological
Cleared on Apr 26, 2002 as substantially equivalent to K010336 (Ge Medical Systems, Inc., 2001) and 2 other predicates after a 66-day review. Its family tree reaches back 3 generations to 1996. 1 of the 449 devices in its family, counting itself, has a Class I recall. 442 later devices descend from it.
- Decided
- Apr 26, 2002
- Review
- 66 days
- Class
- Class II
- Product code
- LLZ
- Recalls
- None
- Predicates
- 3
Its longest line of descent runs back 3 generations to K954678 (1996). 6 ancestors in all, the oldest K941223 (1994). 442 later devices descend from it, 9 citing it directly. 1 of the 449 devices in this family, counting this one, has a Class I recall.
- Root · 3 generations backK954678 Pro VisionAlgotec Systems, Ltd. · 1996
- 2 generations backK980648 Pro VisionAlgotec Systems, Ltd. · 1998
- 1 generation backK992654 Plug 'N View 3D, Version 1.0Voxar Limited · 1999
- This deviceK020546 Fusion 7DMirada Solutions, Ltd. · 2002
- Descendant · cites it directly · 201 of its ownK071950 Syngo TruedSiemens Medical Solutions USA, Inc. · 2007
- Descendant · 2 generations on · 200 of its ownK091373 Syngo TruedSiemens Medical Solutions USA, Inc. · 2009
- Descendant · cites it directly · 164 of its ownK040305 VITREA2 Version 3.5Vital Images, Inc. · 2004
- Descendant · 2 generations on · 143 of its ownK043333 VITREA2, Version 3.7 Medical Image Processing SystemVital Images, Inc. · 2004 · Recalled
- Descendant · cites it directly · 134 of its ownK061214 Aquariusaps ServerTerarecon,Inc. · 2006
Showing 5 of 442 descendants. See all descendants
Descendants cleared per year
Class I recalls in this family
- K250443 MAGNETOM Avanto Fit; MAGNETOM Skyra Fit…6 generations on · 2025
Most influential descendants
Showing 5 of 442 · See all- K071950Syngo TruedSiemens Medical Solutions USA, Inc. · 2007 · cites it directly201descendants
- K091373Syngo TruedSiemens Medical Solutions USA, Inc. · 2009 · 2 generations on200descendants
- K040305VITREA2 Version 3.5Vital Images, Inc. · 2004 · cites it directly164descendants
- K043333VITREA2, Version 3.7 Medical Image Processing SystemVital Images, Inc. · 2004 · 2 generations on143descendants
- K061214Aquariusaps ServerTerarecon,Inc. · 2006 · cites it directly134descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −3 | K954678 | Pro Vision | Algotec Systems, Ltd. | 1996 | — |
| −2 | K980648 | Pro Vision | Algotec Systems, Ltd. | 1998 | — |
| −1 | K992654 | Plug 'N View 3D, Version 1.0 | Voxar Limited | 1999 | — |
| 0 (this device) | K020546 | Fusion 7D | Mirada Solutions, Ltd. | 2002 | — |
| +1 | K071950 | Syngo Trued | Siemens Medical Solutions USA, Inc. | 2007 | — |
| +2 | K091373 | Syngo Trued | Siemens Medical Solutions USA, Inc. | 2009 | — |
| +1 | K040305 | VITREA2 Version 3.5 | Vital Images, Inc. | 2004 | — |
| +2 | K043333 | VITREA2, Version 3.7 Medical Image Processing System | Vital Images, Inc. | 2004 | 1 |
| +1 | K061214 | Aquariusaps Server | Terarecon,Inc. | 2006 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1994 | 1 | 0 |
| 1998 | 1 | 0 |
| 2001 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2003 | 1 | 0 |
| 2004 | 4 | 0 |
| 2005 | 4 | 0 |
| 2006 | 6 | 0 |
| 2007 | 8 | 0 |
| 2008 | 7 | 0 |
| 2009 | 13 | 0 |
| 2010 | 6 | 0 |
| 2011 | 6 | 0 |
| 2012 | 20 | 0 |
| 2013 | 10 | 0 |
| 2014 | 16 | 0 |
| 2015 | 18 | 0 |
| 2016 | 14 | 0 |
| 2017 | 21 | 0 |
| 2018 | 26 | 0 |
| 2019 | 24 | 0 |
| 2020 | 30 | 0 |
| 2021 | 23 | 0 |
| 2022 | 34 | 0 |
| 2023 | 33 | 0 |
| 2024 | 36 | 0 |
| 2025 | 45 | 1 |
| 2026 | 37 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new LLZ device
- #1 K230955 syngo Application Softwarescore 21.5 · 11 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (3)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K010336 | Advantage Windows CT/Pet FusionSummary page 3…t © Mirada Solutions Ltd, 2002 B-3 ms387-0 Fusion7D 510(k) Application Predicate Devices: 510(k) No. | Tradename Manufacturer | Component Applicable to K010336 Advantage Windows CT/PET | General Anatomical to Functional Fusion Electric Registration Component K983256 Advantage Windows Fusi… | 2001 |
| * | K983256 | Advantage Windows (AW) FusionSummary page 3…510(k) No. | Tradename Manufacturer | Component Applicable to K010336 Advantage Windows CT/PET | General Anatomical to Functional Fusion Electric Registration Component K983256 Advantage Windows Fusion General Anatomical to Anatomical Electric Registration Component K992654 Plug ‘n View 3D Voxar Visualiza… | 1998 |
| * | K992654 | Plug 'N View 3D, Version 1.0Summary page 3…General Anatomical to Functional Fusion Electric Registration Component K983256 Advantage Windows Fusion General Anatomical to Anatomical Electric Registration Component K992654 Plug ‘n View 3D Voxar Visualization Strictly Confidential Copyright © Mirada Solutions Ltd, 2002 B4 ms387-0 o f… | 1999 |
What descends from it? (442)
See all 4429 later devices cite it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K071950 | Syngo Trued | 2007 | 201 |
| K040305 | VITREA2 Version 3.5 | 2004 | 164 |
| K061214 | Aquariusaps Server | 2006 | 134 |
| K052305 | Mri Soft Tissue Motion Correction Software VA10A | 2005 | 34 |
| K031779 | Cadstream | 2003 | 19 |
| K041286 | Dynacad V1.0 | 2004 | 17 |
| K083673 | Carestream Pacs, Model Carestream Pacs Vii | 2008 | 12 |
| K052467 | Brain Viewrx Viewer, Version 1.0 | 2005 | 5 |
| K060378 | VITREA2 Version 3.8.1 | 2006 | 1 |
Has anything in its family been recalled? (1 Class I)
No FDA recall names this device.
Relatives with a Class I recall
Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.
- K250443MAGNETOM Avanto Fit; MAGNETOM Skyra Fit; MAGNETOM Sola Fit; MAGNETOM Viato.MobileSiemens Healthcare GmbH · 2025 · 6 generations on · ◆ in the 2025 descendants bar of FIG. 12 Class I recalls
What does this lineage say?
- The line of descent spans 6 years and passes through 3 companies; a new generation was cleared every 2.5 years on median.
- 1 of the 6 ancestors has a recall of any class.
- Of its descendants, K071950 (Siemens Medical Solutions USA, Inc., 2007) has gone furthest, with 201 descendants of its own.
- 8 other devices also cite its predicate K010336.
How does its category compare?
All LLZ devicesLLZ System, Image Processing, Radiological: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · LLZ
58in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · LLZ
173in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · LLZ
11in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · LLZ
116in 2025
MAUDE reports naming product code LLZ, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 76 | 36 | 20 | 152 |
| 2008 | 94 | 52 | 32 | 154 |
| 2009 | 70 | 62 | 21 | 145 |
| 2010 | 51 | 98 | 17 | 145 |
| 2011 | 106 | 79 | 30 | 454 |
| 2012 | 82 | 87 | 12 | 266 |
| 2013 | 95 | 84 | 64 | 1,130 |
| 2014 | 78 | 89 | 6 | 15,631 |
| 2015 | 64 | 90 | 16 | 211 |
| 2016 | 82 | 90 | 12 | 290 |
| 2017 | 78 | 107 | 5 | 104 |
| 2018 | 104 | 105 | 7 | 72 |
| 2019 | 74 | 107 | 2 | 88 |
| 2020 | 81 | 115 | 6 | 82 |
| 2021 | 83 | 116 | 3 | 70 |
| 2022 | 65 | 137 | 4 | 28 |
| 2023 | 87 | 157 | 8 | 26 |
| 2024 | 62 | 131 | 6 | 42 |
| 2025 | 58 | 173 | 11 | 116 |
| 2026 | 45 | 110 | 14 | — |
What is it indicated for?
Fusion7D registers pairs of anatomical and functional volumetric images (e.g. MRI-SPECT, MRI-PET, CT-SPECT, CT-PET), or pairs of anatomical volumetric images (e.g. MRI-MRI, CT-CT and MRI-CT) as a means to ease the comparison of image volume data by the clinician. The result of the registration operation aims to help the clinician obtain a better understanding of the joint information that would otherwise have to be compared visually. This is useful for a…
Read the full statement (116 words)
Fusion7D registers pairs of anatomical and functional volumetric images (e.g. MRI-SPECT, MRI-PET, CT-SPECT, CT-PET), or pairs of anatomical volumetric images (e.g. MRI-MRI, CT-CT and MRI-CT) as a means to ease the comparison of image volume data by the clinician. The result of the registration operation aims to help the clinician obtain a better understanding of the joint information that would otherwise have to be compared visually. This is useful for a wide range of clinical and therapeutic applications. It is important to note that the clinician retains the ultimate responsibility for making the pertinent diagnosis based on their standard procedures including visual comparison of the separate unregistered images. Fusion7D is a complement to these standard procedures.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K020546 · printed Nov 4, 2026
Cite this page
510(k) Report. “K020546: Fusion 7D.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K020546
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026