510(k) Report

510(k) · Cleared

Cleared

Hemochron JR. Signature +

K020798510(k) SpecialCleared Mar 28, 200216-day reviewClass II21 CFR 864.5425

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

International Technidyne Corp. · JPA System, Multipurpose For In Vitro Coagulation Studies

Cleared on Mar 28, 2002 as substantially equivalent to K974799 (International Technidyne Corp., 1998) after a 16-day review. Its family tree reaches back 2 generations to 1993. 3 later devices descend from it.

Decided
Mar 28, 2002
Review
16 days
Class
Class II
Product code
JPA
Recalls
None
Predicates
1

Its longest line of descent runs back 2 generations to K923761 (1993). 3 ancestors in all. 3 later devices descend from it, 1 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 1994: 1 other ancestor2005: 1 descendant cleared2019: 1 descendant cleared2021: 1 descendant clearedK923761 · Itc Microsample Coagulation Analyzer System · International Technidyne Corp. · 1993K974799 · Hemochron JR Generation II, Hemochron JR Signature · International Technidyne Corp. · 1998 · recalled1990200020102020
Other ancestors, by generationDescendants, by generation 2 generations back: 1 other ancestor 1 generation forward: 1 descendant2 generations forward: 1 descendant3 generations forward: 1 descendant K974799 · Hemochron JR Generation II, Hemochron JR Signature · International Technidyne Corp. · 1998 · recalledK923761 · Itc Microsample Coagulation Analyzer System · International Technidyne Corp. · 19930
  1. Root · 2 generations backK923761 Itc Microsample Coagulation Analyzer SystemInternational Technidyne Corp. · 1993
  2. 1 generation backK974799 Hemochron JR Generation II, Hemochron JR SignatureInternational Technidyne Corp. · 1998 · Recalled
  3. This deviceK020798 Hemochron JR. Signature +International Technidyne Corp. · 2002
  4. Descendant · cites it directly · 2 of its ownK050016 Hemochron Signature EliteInternational Technidyne Corp. · 2005
  5. Descendant · 2 generations on · 1 of its ownK193041 Hemochron Signature EliteAccriva Diagnostics, Inc. · 2019
  6. Descendant · 3 generations on · 0 of its ownK202101 GEM Hemochron 100 System, GEM Hemochron 100 Activated Clotting Time…Accriva Diagnostics, Inc. · 2021 · Recalled

Most influential descendants

Showing 3 of 3 · See all
  • K050016Hemochron Signature EliteInternational Technidyne Corp. · 2005 · cites it directly2descendants
  • K193041Hemochron Signature EliteAccriva Diagnostics, Inc. · 2019 · 2 generations on1descendant
  • K202101GEM Hemochron 100 System, GEM Hemochron 100 Activated Clotting Time Plus Test (ACT+)…Accriva Diagnostics, Inc. · 2021 · 3 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K923761Itc Microsample Coagulation Analyzer SystemInternational Technidyne Corp.1993—
−1K974799Hemochron JR Generation II, Hemochron JR SignatureInternational Technidyne Corp.19982
0 (this device)K020798Hemochron JR. Signature +International Technidyne Corp.2002—
+1K050016Hemochron Signature EliteInternational Technidyne Corp.2005—
+2K193041Hemochron Signature EliteAccriva Diagnostics, Inc.2019—
+3K202101GEM Hemochron 100 System, GEM Hemochron 100 Activated Clotting Time Plus Test…Accriva Diagnostics, Inc.20211

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199410

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200510
201910
202110
FIG. 1 — Lineage of K020798, 1993–2021Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in JPA? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new JPA device

  1. #1 K243858 TEG 6s Hemostasis System Citrated: K, KH, RT…score 12.0 · 2 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K974799Hemochron JR Generation II, Hemochron JR Signature
Summary page 1
…ystem Product Name: HEMOCHRON® Jr. Signature + Predicate Device The Signature+ is substantially equivalent to the previously cleared Hemochron Jr. Signature instrument K974799. Device Description and Technological Characteristics The Hemochron Jr. Signature + instrument is an upgrade to the current Hem…
International Technidyne Corp.19982

What descends from it? (3)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K050016Hemochron Signature EliteInternational Technidyne Corp.20052

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 9 years and passes through 1 company; a new generation was cleared every 5.5 years on median.
  • 2 of the 3 ancestors have a recall of any class.
  • Of its descendants, K050016 (International Technidyne Corp., 2005) has gone furthest, with 2 descendants of its own.

How does its category compare?

All JPA devices

JPA System, Multipurpose For In Vitro Coagulation Studies: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · JPA

3in 2025

2007: 12008: 22009: 62010: 12011: 12013: 12015: 22016: 62017: 42018: 12019: 32021: 12022: 12023: 32024: 12025: 32026 (partial year): 1
2007high 6 (2009) · low 0 (2012)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · JPA

30in 2025

2009: 91 days median2016: 114 days median2017: 117 days median2019: 175 days median2023: 506 days median2025: 30 days median
2007high 506 (2023) · low 30 (2025)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · JPA

1in 2020

2007: 12010: 62011: 42012: 12016: 32020: 12026 (partial year): 1
2007high 6 (2010) · low 0 (2008)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · JPA

11in 2025

2007: 1,7442008: 9182009: 1,3632010: 7272011: 1612012: 522013: 432014: 482015: 452016: 62017: 152018: 392019: 272020: 182021: 72022: 92023: 112024: 82025: 11
2007high 1,744 (2007) · low 6 (2016)2025

MAUDE reports naming product code JPA, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—11,744
20082—0918
200969101,363
20101—6727
20111—4161
20120—152
20131—043
20140—048
20152—045
2016611436
20174117015
20181—039
20193175027
20200—118
20211—07
20221—09
20233506011
20241—08
2025330011
20261—1—

What is it indicated for?

The HEMOCHRON® Signature+ is a portable, battery-operated point of care microcoagulation instrument designed to perform whole blood coagulation tests using fresh or citrated whole blood. The system is intended for use in many clinical settings requiring point-of-care testing. Whole blood test results are displayed as clotting times (in seconds). The Signature+ also displays correlated celite equivalent ACT values, APTT and PT plasma equivalent values, and the PT INR value.

For In Vitro Diagnostic Use Only

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K020798: Hemochron JR. Signature +.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K020798

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026