510(k) Report

510(k) · Cleared

Cleared

Smartwire/Smartmap Pressure System

K021219510(k) SpecialCleared May 17, 200230-day reviewClass II21 CFR 870.1330

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Jomed, Inc. · DQX Wire, Guide, Catheter

Cleared on May 17, 2002 as substantially equivalent to K965140 (Cardio Metrics, Inc., 1997) after a 30-day review. Its family tree reaches back 2 generations to 1982. 7 of the 103 devices in its family, counting itself, have a Class I recall. 90 later devices descend from it.

Decided
May 17, 2002
Review
30 days
Class
Class II
Product code
DQX
Recalls
None
Predicates
1

Its longest line of descent runs back 2 generations to K823434 (1982). 12 ancestors in all. 90 later devices descend from it, 6 citing it directly. 7 of the 103 devices in this family, counting this one, have a Class I recall.

Other ancestors, by year clearedDescendants, by year cleared 1996: 2 other ancestors1995: 1 other ancestor1994: 2 other ancestors1993: 1 other ancestor1992: 2 other ancestors1991: 1 other ancestor1986: 1 other ancestor2007: 1 descendant cleared2010: 3 descendants cleared2004: 2 descendants cleared2008: 4 descendants cleared2016: 6 descendants cleared, 3 with a Class I recall32019: 5 descendants cleared2013: 9 descendants cleared, 2 with a Class I recall22015: 9 descendants cleared2018: 4 descendants cleared, 1 with a Class I recall12011: 5 descendants cleared2009: 1 descendant cleared2021: 3 descendants cleared2012: 4 descendants cleared, 1 with a Class I recall12026: 5 descendants cleared2020: 4 descendants cleared2014: 5 descendants cleared2017: 6 descendants cleared2022: 4 descendants cleared2025: 6 descendants cleared2024: 3 descendants cleared2023: 1 descendant clearedK823434 · Mikro-Tip Catheter Pressure Transducer · Millar Instruments, Inc. · 1982K965140 · Cardiometrics Wavewire/Wavemap Pressure System · Cardio Metrics, Inc. · 199719801990200020102020
Other ancestors, by generationDescendants, by generation 2 generations back: 10 other ancestors 1 generation forward: 6 descendants2 generations forward: 9 descendants, 1 with a Class I recall13 generations forward: 11 descendants4 generations forward: 16 descendants, 2 with a Class I recall25 generations forward: 19 descendants, 3 with a Class I recall36 generations forward: 18 descendants7 generations forward: 8 descendants, 1 with a Class I recall18 generations forward: 3 descendants K965140 · Cardiometrics Wavewire/Wavemap Pressure System · Cardio Metrics, Inc. · 1997K823434 · Mikro-Tip Catheter Pressure Transducer · Millar Instruments, Inc. · 19820+5
  1. Root · 2 generations backK823434 Mikro-Tip Catheter Pressure TransducerMillar Instruments, Inc. · 1982
  2. 1 generation backK965140 Cardiometrics Wavewire/Wavemap Pressure SystemCardio Metrics, Inc. · 1997
  3. This deviceK021219 Smartwire/Smartmap Pressure SystemJomed, Inc. · 2002
  4. Descendant · cites it directly · 85 of its ownK041134 Combomap Pressure and Flow SystemVolcano Therapeutics, Inc. · 2004
  5. Descendant · cites it directly · 44 of its ownK070487 Smartwire Pressure Guide Wire, Model 66XXVolcano Corporation · 2007
  6. Descendant · 2 generations on · 40 of its ownK081625 Flowpicc StyletVasonova, Inc. · 2008
  7. Descendant · 2 generations on · 39 of its ownK081626 Flowpicc ConsoleVasonova, Inc. · 2008
  8. Descendant · 3 generations on · 38 of its ownK091324 Sherlock 3CG Tip Positioning System, Sherlock 3CG Tip Positioning…C.R. Bard, Inc. · 2009 · Recalled

Showing 5 of 90 descendants. See all descendants

Descendants cleared per year

2004: 22007: 12008: 42009: 12010: 32011: 52012: 42013: 92014: 52015: 92016: 62017: 62018: 42019: 52020: 42021: 32022: 42023: 12024: 32025: 62026: 5
2004high 9 (2013) · low 0 (2005)2026

Class I recalls in this family

Most influential descendants

Showing 5 of 90 · See all
  • K041134Combomap Pressure and Flow SystemVolcano Therapeutics, Inc. · 2004 · cites it directly85descendants
  • K070487Smartwire Pressure Guide Wire, Model 66XXVolcano Corporation · 2007 · cites it directly44descendants
  • K081625Flowpicc StyletVasonova, Inc. · 2008 · 2 generations on40descendants
  • K081626Flowpicc ConsoleVasonova, Inc. · 2008 · 2 generations on39descendants
  • K091324Sherlock 3CG Tip Positioning System, Sherlock 3CG Tip Positioning System StyletC.R. Bard, Inc. · 2009 · 3 generations on38descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K823434Mikro-Tip Catheter Pressure TransducerMillar Instruments, Inc.1982—
−1K965140Cardiometrics Wavewire/Wavemap Pressure SystemCardio Metrics, Inc.1997—
0 (this device)K021219Smartwire/Smartmap Pressure SystemJomed, Inc.2002—
+1K041134Combomap Pressure and Flow SystemVolcano Therapeutics, Inc.2004—
+1K070487Smartwire Pressure Guide Wire, Model 66XXVolcano Corporation2007—
+2K081625Flowpicc StyletVasonova, Inc.2008—
+2K081626Flowpicc ConsoleVasonova, Inc.2008—
+3K091324Sherlock 3CG Tip Positioning System, Sherlock 3CG Tip Positioning System StyletC.R. Bard, Inc.200911

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198610
199110
199220
199310
199420
199510
199620

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200420
200710
200840
200910
201030
201150
201241
201392
201450
201590
201663
201760
201841
201950
202040
202130
202240
202310
202430
202560
202650
FIG. 1 — Lineage of K021219, 1982–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

7 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DQX device

  1. #1 K213854 SavvyWirescore 15.7 · 10 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K965140Cardiometrics Wavewire/Wavemap Pressure System
Summary page 1
…tip pressure transducer Vessel occlusion transducer Patient transducer and electrical cable (including connector) Predicate Device: = WaveWire/WaveMap Pressure System, K965140 Device Description: The Jometrics SmartWire/SmartMap Pressure System consists of the SmartWire and the SmartMap. Additionally,…
Cardio Metrics, Inc.1997—

Also cleared against K965140: 4 other devices →

What descends from it? (90)

See all 90

6 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K041134Combomap Pressure and Flow SystemVolcano Therapeutics, Inc.200485
K070487Smartwire Pressure Guide Wire, Model 66XXVolcano Corporation200744
K042996Combowire Pressure and Flow Guide Wire, Combotip Pressure and Flow Guide WireVolcano Therapeutics, Inc.200429
K071554Volcano S5/S5I Intravascular Imaging and Pressure SystemVolcano Corporation200828
K082229S5/S5I Series Intravascular Imaging and Pressure System, Combomap Pressure and Flow SystemVolcano Corporation200825
K100930Primewire Prestiage Pressure Guide Wire, Models 8185, 8185J, 8300, 8300JVolcano Corporation201014

Has anything in its family been recalled? (7 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K172258Novasight Hybrid SystemConavi Medical, Inc. · 2018 · 2 generations on · ◆ in the 2018 descendants bar of FIG. 11 Class I recall
  • K122545CG+ Arrow Picc Powered by Arrow VPS StyletArrow International (Subsidiary of Teleflex Inc.) · 2012 · 4 generations on · ◆ in the 2012 descendants bar of FIG. 11 Class I recall
  • K132133CG+ Arrow Jacc Powered by Arrow VPS StyletArrow International (Subsidiary of Teleflex Inc.) · 2013 · 4 generations on · ◆ in the 2013 descendants bar of FIG. 11 Class I recall
  • K130876CG+ Arrow Picc Powered by Arrow VPS StyletArrow International, Inc. · 2013 · 5 generations on · ◆ in the 2013 descendants bar of FIG. 11 Class I recall
  • K153423CG+ Arrow JACC powered by Arrow VPS Stylet, CG+ Arrow JACCArrow International, Inc. (Subsidiary of Teleflex, Inc.) · 2016 · 5 generations on · ◆ in the 2016 descendants bar of FIG. 11 Class I recall
  • K153487CG+ Arrow PICC powered by Arrow VPS Stylet PLUS and Arrow VPS Stylet PLUSArrow International, Inc. (Subsidiary of Teleflex, Inc.) · 2016 · 5 generations on · ◆ in the 2016 descendants bar of FIG. 11 Class I recall
  • K160925VPS Rhythm Device with TipTracker TechnologyArrow International, Inc. (A Subsidiary of Teleflex, Inc.) · 2016 · 7 generations on · ◆ in the 2016 descendants bar of FIG. 11 Class I recall

What does this lineage say?

  • The line of descent spans 20 years and passes through 3 companies; a new generation was cleared every 14.7 years on median.
  • None of the 12 ancestors has a recall.
  • Of its descendants, K041134 (Volcano Therapeutics, Inc., 2004) has gone furthest, with 85 descendants of its own.
  • 4 other devices also cite its predicate K965140.

How does its category compare?

All DQX devices

DQX Wire, Guide, Catheter: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · DQX

10in 2025

2007: 142008: 192009: 182010: 212011: 182012: 202013: 182014: 182015: 152016: 142017: 192018: 192019: 132020: 142021: 62022: 152023: 102024: 112025: 102026 (partial year): 12
2007high 21 (2010) · low 6 (2021)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DQX

177in 2025

2007: 85 days median2008: 87 days median2009: 87 days median2010: 63 days median2011: 43 days median2012: 62 days median2013: 119 days median2014: 103 days median2015: 112 days median2016: 179 days median2017: 85 days median2018: 114 days median2019: 173 days median2020: 106 days median2021: 161 days median2022: 212 days median2023: 136 days median2024: 134 days median2025: 177 days median2026 (partial year): 145 days median
2007high 212 (2022) · low 43 (2011)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DQX

3in 2024

2007: 122008: 72009: 492010: 342011: 32012: 52013: 7, 4 Class I2015: 12016: 2, 2 Class I2017: 172018: 92019: 22020: 1, 1 Class I2024: 32026 (partial year): 4, 1 Class I
2007high 49 (2009) · low 0 (2014)2026

Class I (8 since 2007) Class II/III not classified

Adverse event reports per year · DQX

2,178in 2025

2007: 7602008: 7152009: 6872010: 9872011: 1,3112012: 1,3372013: 1,4742014: 1,3232015: 1,3232016: 1,4662017: 1,5242018: 1,7372019: 1,6792020: 1,5362021: 1,7132022: 1,6472023: 2,0682024: 2,2102025: 2,178
2007high 2,210 (2024) · low 687 (2009)2025

MAUDE reports naming product code DQX, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007148512760
200819877715
2009188749687
2010216334987
2011184331,311
2012206251,337
2013181197 (4)1,474
20141810301,323
20151511211,323
2016141792 (2)1,466
20171985171,524
20181911491,737
20191317321,679
2020141061 (1)1,536
2021616101,713
20221521201,647
20231013602,068
20241113432,210
20251017702,178
2026121454 (1)—

What is it indicated for?

The SmartWire/SmartMap Pressure System is indicated for use in all blood vessels, including coronary and peripheral arteries to measures blood pressure during diagnostic angiography and/or interventional procedures.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K021219: Smartwire/Smartmap Pressure System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K021219

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026