510(k) Report

510(k) · Cleared

Recalled · 2004

Cypress Ultrasound System

K021497510(k) SpecialCleared Jul 9, 200261-day reviewClass II21 CFR 892.1550Recalls 2

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Acuson Corp. · IYN System, Imaging, Pulsed Doppler, Ultrasonic

Cleared on Jul 9, 2002 as substantially equivalent to K010950 (Acuson Corp., 2001) and 2 other predicates after a 61-day review. Its family tree reaches back 3 generations to 1994. 2 of the 906 devices in its family, counting itself, have a Class I recall. 898 later devices descend from it. It has been recalled 2 times.

Decided
Jul 9, 2002
Review
61 days
Class
Class II
Product code
IYN
Recalls
2
Predicates
3

Its longest line of descent runs back 3 generations to K934041 (1994). 7 ancestors in all, the oldest K891689 (1989). 898 later devices descend from it, 5 citing it directly. 2 of the 906 devices in this family, counting this one, have a Class I recall.

Other ancestors, by year clearedDescendants, by year cleared 2001: 1 other ancestor1999: 1 other ancestor1994: 1 other ancestor1989: 1 other ancestor2008: 5 descendants cleared2005: 3 descendants cleared2004: 1 descendant cleared2002: 1 descendant cleared2006: 2 descendants cleared2009: 9 descendants cleared2007: 4 descendants cleared2010: 10 descendants cleared2011: 22 descendants cleared2012: 29 descendants cleared2013: 38 descendants cleared2016: 63 descendants cleared2015: 53 descendants cleared2018: 65 descendants cleared2014: 51 descendants cleared2017: 74 descendants cleared2020: 72 descendants cleared2019: 49 descendants cleared2022: 59 descendants cleared2026: 51 descendants cleared2025: 75 descendants cleared, 2 with a Class I recall22021: 51 descendants cleared2023: 54 descendants cleared2024: 57 descendants clearedK934041 · Hewlett Packard Conos Ultrasound Imaging System Modification · Hewlett-Packard Co. · 1994K964309 · Sonos 2000, Sonos 2500 (M2406 a) · Hewlett-Packard Co. · 1997K982800 · Ecton Lynx Ultrasound System · Ecton, Inc. · 19981990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 2 other ancestors2 generations back: 2 other ancestors 1 generation forward: 5 descendants2 generations forward: 10 descendants3 generations forward: 21 descendants4 generations forward: 26 descendants5 generations forward: 36 descendants6 generations forward: 56 descendants7 generations forward: 82 descendants8 generations forward: 134 descendants9 generations forward: 125 descendants, 2 with a Class I recall210 generations forward: 111 descendants11 generations forward: 85 descendants12 generations forward: 74 descendants13 generations forward: 50 descendants14 generations forward: 33 descendants15 generations forward: 27 descendants16 generations forward: 15 descendants17 generations forward: 6 descendants18 generations forward: 2 descendants K982800 · Ecton Lynx Ultrasound System · Ecton, Inc. · 1998K964309 · Sonos 2000, Sonos 2500 (M2406 a) · Hewlett-Packard Co. · 1997K934041 · Hewlett Packard Conos Ultrasound Imaging System Modification · Hewlett-Packard Co. · 19940+5+10+15
  1. Root · 3 generations backK934041 Hewlett Packard Conos Ultrasound Imaging System ModificationHewlett-Packard Co. · 1994
  2. 2 generations backK964309 Sonos 2000, Sonos 2500 (M2406 a)Hewlett-Packard Co. · 1997
  3. 1 generation backK982800 Ecton Lynx Ultrasound SystemEcton, Inc. · 1998
  4. This deviceK021497 Cypress Ultrasound SystemAcuson Corp. · 2002
  5. Descendant · cites it directly · 827 of its ownK042055 Cypress Ultrasound SystemSiemens Medical Solutions USA, Inc. · 2004
  6. Descendant · 2 generations on · 806 of its ownK052021 V5MS Transducer and MPT7-4 Multiplane Transesophageal TransducerSiemens Medical Solutions USA, Inc. · 2005 · Recalled
  7. Descendant · 3 generations on · 802 of its ownK063138 Modification to Acuson Antares Ultrasound SystemSiemens Medical Solutions USA, Inc. · 2006
  8. Descendant · 4 generations on · 801 of its ownK063803 Acuson Antares Diagnostic Ultrasound SystemSiemens Medical Solutions USA, Inc., Ultrasound DI · 2007 · Recalled
  9. Descendant · 5 generations on · 800 of its ownK072786 Acuson S2000 Ultrasound SystemSiemens Medical Solutions USA, Inc. · 2007

Showing 5 of 898 descendants. See all descendants

Descendants cleared per year

2002: 12004: 12005: 32006: 22007: 42008: 52009: 92010: 102011: 222012: 292013: 382014: 512015: 532016: 632017: 742018: 652019: 492020: 722021: 512022: 592023: 542024: 572025: 752026: 51
2002high 75 (2025) · low 0 (2003)2026

Class I recalls in this family

Most influential descendants

Showing 5 of 898 · See all
  • K042055Cypress Ultrasound SystemSiemens Medical Solutions USA, Inc. · 2004 · cites it directly827descendants
  • K052021V5MS Transducer and MPT7-4 Multiplane Transesophageal TransducerSiemens Medical Solutions USA, Inc. · 2005 · 2 generations on806descendants
  • K063138Modification to Acuson Antares Ultrasound SystemSiemens Medical Solutions USA, Inc. · 2006 · 3 generations on802descendants
  • K063803Acuson Antares Diagnostic Ultrasound SystemSiemens Medical Solutions USA, Inc., Ultrasound DI · 2007 · 4 generations on801descendants
  • K072786Acuson S2000 Ultrasound SystemSiemens Medical Solutions USA, Inc. · 2007 · 5 generations on800descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K934041Hewlett Packard Conos Ultrasound Imaging System ModificationHewlett-Packard Co.1994—
−2K964309Sonos 2000, Sonos 2500 (M2406 a)Hewlett-Packard Co.1997—
−1K982800Ecton Lynx Ultrasound SystemEcton, Inc.1998—
0 (this device)K021497Cypress Ultrasound SystemAcuson Corp.2002—
+1K042055Cypress Ultrasound SystemSiemens Medical Solutions USA, Inc.2004—
+2K052021V5MS Transducer and MPT7-4 Multiplane Transesophageal TransducerSiemens Medical Solutions USA, Inc.20051
+3K063138Modification to Acuson Antares Ultrasound SystemSiemens Medical Solutions USA, Inc.2006—
+4K063803Acuson Antares Diagnostic Ultrasound SystemSiemens Medical Solutions USA, Inc., Ultrasound DI20079
+5K072786Acuson S2000 Ultrasound SystemSiemens Medical Solutions USA, Inc.2007—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198910
199410
199910
200110

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200210
200410
200530
200620
200740
200850
200990
2010100
2011220
2012290
2013380
2014510
2015530
2016630
2017740
2018650
2019490
2020720
2021510
2022590
2023540
2024570
2025752
2026510
FIG. 1 — Lineage of K021497, 1994–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

2 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new IYN device

  1. #1 K240850 EPIQ Series Diagnostic Ultrasound Systems…score 32.1 · 24 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K010950Cypress System
Summary page 1
…rasonic Pulsed Echo Imaging System (90 IYO), class II (21 C.F.R. $892.1560) Diagnostic Ultrasound Transducer (90 ITX), class II (21 C.F.R. $892.1570) Predicate Devices: K010950,6/27/2001, cleared as the Acuson Cypress Ultrasound System. K982800, 9/22/98, cleared as the Ecton Lynx Ultrasound System, marke…
Acuson Corp.2001—
*K982800Ecton Lynx Ultrasound System
Summary page 1
….1560) Diagnostic Ultrasound Transducer (90 ITX), class II (21 C.F.R. $892.1570) Predicate Devices: K010950,6/27/2001, cleared as the Acuson Cypress Ultrasound System. K982800, 9/22/98, cleared as the Ecton Lynx Ultrasound System, marketed as the Acuson Cypress Ultrasound System with subsequent modificat…
Ecton, Inc.1998—
*K991872Lynx Ultrasound System
Summary page 1
…press Ultrasound System. K982800, 9/22/98, cleared as the Ecton Lynx Ultrasound System, marketed as the Acuson Cypress Ultrasound System with subsequent modifications. K99 1872, 6/16/99, cleared as Ecton Lynx Ultrasound System, marketed Acuson Cypress Ultrasound System with subsequent modifications. Dev…
Ecton, Inc.1999—

Also cleared against K010950: 3 other devices →

What descends from it? (898)

See all 898

5 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K042055Cypress Ultrasound SystemSiemens Medical Solutions USA, Inc.2004827
K052331Acuson Cypress Ultrasound SystemSiemens Medical Solutions USA, Inc.2005167
K022896CSV12 Software ViewerAcuson Corp.2002104
K060992Syngo US WorkplaceSiemens Medical Solutions200697
K080234Terason Echo T/3000 Ultrasound System with Stress EchoTeratech Corp.200884

Has anything in its family been recalled? (2 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Feb 2, 2004Not classifiedZ-0744-04Othersoftware problem - mode does not appear on screen
Apr 1, 2003Not classifiedZ-0975-03Othersoftware problem - loss of data

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K242670Lumify Diagnostic Ultrasound SystemPhilips Ultrasound · 2025 · 9 generations on · ◆ in the 2025 descendants bar of FIG. 11 Class I recall
  • K242519Lumify Diagnostic Ultrasound SystemPhilips Ultrasound · 2025 · 9 generations on · ◆ in the 2025 descendants bar of FIG. 11 Class I recall

What does this lineage say?

  • The line of descent spans 8 years and passes through 3 companies; a new generation was cleared every 2.6 years on median.
  • None of the 7 ancestors has a recall.
  • Of its descendants, K042055 (Siemens Medical Solutions USA, Inc., 2004) has gone furthest, with 827 descendants of its own.
  • 3 other devices also cite its predicate K010950.

How does its category compare?

All IYN devices

IYN System, Imaging, Pulsed Doppler, Ultrasonic: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · IYN

57in 2025

2007: 132008: 252009: 182010: 292011: 392012: 432013: 512014: 562015: 542016: 602017: 642018: 592019: 472020: 572021: 462022: 532023: 442024: 502025: 572026 (partial year): 44
2007high 64 (2017) · low 13 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · IYN

124in 2025

2007: 26 days median2008: 18 days median2009: 29 days median2010: 67 days median2011: 46 days median2012: 37 days median2013: 60 days median2014: 39 days median2015: 55 days median2016: 56 days median2017: 83 days median2018: 85 days median2019: 79 days median2020: 72 days median2021: 105 days median2022: 105 days median2023: 115 days median2024: 119 days median2025: 124 days median2026 (partial year): 107 days median
2007high 124 (2025) · low 18 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · IYN

10in 2025

2007: 162008: 122009: 82010: 102011: 82012: 32013: 82014: 22015: 32016: 22018: 72020: 42021: 82022: 102023: 42024: 12025: 102026 (partial year): 2, 1 Class I
2007high 16 (2007) · low 0 (2017)2026

Class I (1 since 2007) Class II/III not classified

Adverse event reports per year · IYN

610in 2025

2007: 32008: 22009: 92010: 172011: 182012: 202013: 182014: 482015: 1162016: 1452017: 1462018: 852019: 592020: 672021: 2132022: 1862023: 2292024: 2662025: 610
2007high 610 (2025) · low 2 (2008)2025

MAUDE reports naming product code IYN, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071326163
20082518122
2009182989
201029671017
20113946818
20124337320
20135160818
20145639248
201554553116
201660562145
201764830146
20185985785
20194779059
20205772467
2021461058213
20225310510186
2023441154229
2024501191266
20255712410610
2026441072 (1)—

What is it indicated for?

Diagnostic ultrasound imaging or fluid flow analysis of the human body as follows:

Diagnostic ultrasound imaging or fluid flow analysis of the human body as follows:

Diagnostic ultrasound imaging or fluid flow analysis of the human body as follows:

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K021497: Cypress Ultrasound System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K021497

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026