Lumify Diagnostic Ultrasound System

K242519510(k) TraditionalCleared May 15, 2025265-day reviewClass II21 CFR 892.1550Recalls 2 (1 Class I)

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Philips Ultrasound · IYN System, Imaging, Pulsed Doppler, Ultrasonic

Cleared on May 15, 2025 as substantially equivalent to K192226 (Philips Health Care, 2019) after a 265-day review. Its family tree reaches back 20 generations to 1995. 7 of the 176 devices in its family, counting itself, have a Class I recall. It has been recalled 2 times, including a Class I recall.

Decided
May 15, 2025
Review
265 days
Class
Class II
Product code
IYN
Recalls
2 (1 Class I)
Predicates
1

Its longest line of descent runs back 20 generations to K935595 (1995). 175 ancestors in all, the oldest K850478 (1985). No later device cites it as a predicate yet. 7 of the 176 devices in this family, counting this one, have a Class I recall.

Other ancestors, by year cleared 2012: 2 other ancestors2011: 1 other ancestor2007: 3 other ancestors2010: 1 other ancestor2009: 3 other ancestors2005: 9 other ancestors2004: 11 other ancestors, 1 with a Class I recall12003: 9 other ancestors1999: 16 other ancestors2006: 2 other ancestors2002: 17 other ancestors2000: 14 other ancestors, 1 with a Class I recall11997: 9 other ancestors1996: 7 other ancestors, 1 with a Class I recall11992: 2 other ancestors1991: 1 other ancestor2001: 13 other ancestors1998: 13 other ancestors, 3 with a Class I recall31995: 7 other ancestors1994: 6 other ancestors1993: 2 other ancestors1988: 1 other ancestor1986: 1 other ancestor1985: 1 other ancestor1989: 3 other ancestors1987: 1 other ancestorReference device: K120321 · Clearvue 350/550 Diagnostic Ultrasound System · Philips Health Care · 2012 · recalledReference device: K240850 · EPIQ Series Diagnostic Ultrasound Systems; Affiniti Series Diagnostic Ultrasound Systems · Philips Ultrasound, LLC · 2024K935595 · Acuson Model 3001 · Acuson Corp. · 1995K973767 · Harmonic Imaging with Contrast · Acuson Corp. · 1997K022567 · Sequoia Signature II Diagnostic Ultrasound System · Acuson Corp. · 2002K032114 · Sequoia 8.0 Diagnostic Ultrasound System · Siemens Medical Solutions USA, Inc. · 2003×3: 3 generations cleared close together, K041319 (2004), K042770 (2004), K050240 (2005) K052894 · Sonoline G60 S Ultrasound System · Siemens Medical Solutions USA, Inc. · 2005 · recalled×2: 2 generations cleared close together, K063138 (2006), K063803 (2007) K072786 · Acuson S2000 Ultrasound System · Siemens Medical Solutions USA, Inc. · 2007K091970 · Aixplorer Ultrasound System · Supersonic Imagine · 2009K102041 · Aixplorer · Supersonic Imagine · 2010K112255 · Aixplorer · Supersonic Imagine · 2012×3: 3 generations cleared close together, K130499 (2013), K132304 (2013), K133833 (2014) K152899 · Philips Lumify Diagnostic Ultrasound System · Philips Healthcare, Inc. · 2015 · recalledK162549 · Lumify Ultrasound System · Philips Health Care · 2016 · recalledK192226 · Lumify Diagnostic Ultrasound System · Philips Health Care · 2019 · recalled1990200020102020
Other ancestors, by generation 5 generations back: 3 other ancestors6 generations back: 8 other ancestors7 generations back: 17 other ancestors8 generations back: 53 other ancestors, 6 with a Class I recall69 generations back: 27 other ancestors10 generations back: 24 other ancestors11 generations back: 11 other ancestors12 generations back: 8 other ancestors13 generations back: 4 other ancestors K192226 · Lumify Diagnostic Ultrasound System · Philips Health Care · 2019 · recalledK162549 · Lumify Ultrasound System · Philips Health Care · 2016 · recalledK152899 · Philips Lumify Diagnostic Ultrasound System · Philips Healthcare, Inc. · 2015 · recalledK133833 · Nuvis Diagnostic Ultrasound System · Philips Ultrasound, Inc. · 2014 · recalledK132304 · Epiq Diagnostic Ultrasound System · Philips Ultrasound, Inc. · 2013 · recalledK130499 · IU22 Diagnostic Ultrasound System · Philips Ultrasound, Inc. · 2013 · recalledK112255 · Aixplorer · Supersonic Imagine · 2012K102041 · Aixplorer · Supersonic Imagine · 2010K091970 · Aixplorer Ultrasound System · Supersonic Imagine · 2009K072786 · Acuson S2000 Ultrasound System · Siemens Medical Solutions USA, Inc. · 2007K063803 · Acuson Antares Diagnostic Ultrasound System · Siemens Medical Solutions USA, Inc., Ultrasound DI · 2007 · recalledK063138 · Modification to Acuson Antares Ultrasound System · Siemens Medical Solutions USA, Inc. · 2006K052894 · Sonoline G60 S Ultrasound System · Siemens Medical Solutions USA, Inc. · 2005 · recalledK050240 · Modification to Acuson CV70 Cardiovascular System · Siemens Medical Solutions USA, Inc. · 2005 · recalledK042770 · Modification to Acuson CV70 Cardiovascular System · Siemens Medical Solutions USA, Inc. · 2004 · recalledK041319 · Sequoia Diagnostic Ultrasound System · Siemens Medical Solutions USA, Inc. · 2004K032114 · Sequoia 8.0 Diagnostic Ultrasound System · Siemens Medical Solutions USA, Inc. · 2003K022567 · Sequoia Signature II Diagnostic Ultrasound System · Acuson Corp. · 2002K973767 · Harmonic Imaging with Contrast · Acuson Corp. · 1997K935595 · Acuson Model 3001 · Acuson Corp. · 1995−20−15−10−50
  1. Root · 20 generations backK935595 Acuson Model 3001Acuson Corp. · 1995
  2. 16 generations between
  3. 3 generations backK152899 Philips Lumify Diagnostic Ultrasound SystemPhilips Healthcare, Inc. · 2015 · Recalled
  4. 2 generations backK162549 Lumify Ultrasound SystemPhilips Health Care · 2016 · Recalled
  5. 1 generation backK192226 Lumify Diagnostic Ultrasound SystemPhilips Health Care · 2019 · Recalled
  6. This deviceK242519 Lumify Diagnostic Ultrasound SystemPhilips Ultrasound · 2025
Show all 20 generations
  1. Root · 20 generations backK935595 Acuson Model 3001Acuson Corp. · 1995
  2. 19 generations backK973767 Harmonic Imaging with ContrastAcuson Corp. · 1997
  3. 18 generations backK022567 Sequoia Signature II Diagnostic Ultrasound SystemAcuson Corp. · 2002
  4. 17 generations backK032114 Sequoia 8.0 Diagnostic Ultrasound SystemSiemens Medical Solutions USA, Inc. · 2003
  5. 16 generations backK041319 Sequoia Diagnostic Ultrasound SystemSiemens Medical Solutions USA, Inc. · 2004
  6. 15 generations backK042770 Modification to Acuson CV70 Cardiovascular SystemSiemens Medical Solutions USA, Inc. · 2004 · Recalled
  7. 14 generations backK050240 Modification to Acuson CV70 Cardiovascular SystemSiemens Medical Solutions USA, Inc. · 2005 · Recalled
  8. 13 generations backK052894 Sonoline G60 S Ultrasound SystemSiemens Medical Solutions USA, Inc. · 2005 · Recalled
  9. 12 generations backK063138 Modification to Acuson Antares Ultrasound SystemSiemens Medical Solutions USA, Inc. · 2006
  10. 11 generations backK063803 Acuson Antares Diagnostic Ultrasound SystemSiemens Medical Solutions USA, Inc., Ultrasound DI · 2007 · Recalled
  11. 10 generations backK072786 Acuson S2000 Ultrasound SystemSiemens Medical Solutions USA, Inc. · 2007
  12. 9 generations backK091970 Aixplorer Ultrasound SystemSupersonic Imagine · 2009
  13. 8 generations backK102041 AixplorerSupersonic Imagine · 2010
  14. 7 generations backK112255 AixplorerSupersonic Imagine · 2012
  15. 6 generations backK130499 IU22 Diagnostic Ultrasound SystemPhilips Ultrasound, Inc. · 2013 · Recalled
  16. 5 generations backK132304 Epiq Diagnostic Ultrasound SystemPhilips Ultrasound, Inc. · 2013 · Recalled
  17. 4 generations backK133833 Nuvis Diagnostic Ultrasound SystemPhilips Ultrasound, Inc. · 2014 · Recalled
  18. 3 generations backK152899 Philips Lumify Diagnostic Ultrasound SystemPhilips Healthcare, Inc. · 2015 · Recalled
  19. 2 generations backK162549 Lumify Ultrasound SystemPhilips Health Care · 2016 · Recalled
  20. 1 generation backK192226 Lumify Diagnostic Ultrasound SystemPhilips Health Care · 2019 · Recalled
  21. This deviceK242519 Lumify Diagnostic Ultrasound SystemPhilips Ultrasound · 2025

Class I recalls in this family

View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−20K935595Acuson Model 3001Acuson Corp.1995—
−19K973767Harmonic Imaging with ContrastAcuson Corp.1997—
−18K022567Sequoia Signature II Diagnostic Ultrasound SystemAcuson Corp.2002—
−17K032114Sequoia 8.0 Diagnostic Ultrasound SystemSiemens Medical Solutions USA, Inc.2003—
−16K041319Sequoia Diagnostic Ultrasound SystemSiemens Medical Solutions USA, Inc.2004—
−15K042770Modification to Acuson CV70 Cardiovascular SystemSiemens Medical Solutions USA, Inc.20041
−14K050240Modification to Acuson CV70 Cardiovascular SystemSiemens Medical Solutions USA, Inc.20051
−13K052894Sonoline G60 S Ultrasound SystemSiemens Medical Solutions USA, Inc.20051
−12K063138Modification to Acuson Antares Ultrasound SystemSiemens Medical Solutions USA, Inc.2006—
−11K063803Acuson Antares Diagnostic Ultrasound SystemSiemens Medical Solutions USA, Inc., Ultrasound DI20079
−10K072786Acuson S2000 Ultrasound SystemSiemens Medical Solutions USA, Inc.2007—
−9K091970Aixplorer Ultrasound SystemSupersonic Imagine2009—
−8K102041AixplorerSupersonic Imagine2010—
−7K112255AixplorerSupersonic Imagine2012—
−6K130499IU22 Diagnostic Ultrasound SystemPhilips Ultrasound, Inc.20132
−5K132304Epiq Diagnostic Ultrasound SystemPhilips Ultrasound, Inc.201336
−4K133833Nuvis Diagnostic Ultrasound SystemPhilips Ultrasound, Inc.20143
−3K152899Philips Lumify Diagnostic Ultrasound SystemPhilips Healthcare, Inc.20154
−2K162549Lumify Ultrasound SystemPhilips Health Care20166
−1K192226Lumify Diagnostic Ultrasound SystemPhilips Health Care20195
0 (this device)K242519Lumify Diagnostic Ultrasound SystemPhilips Ultrasound2025—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198510
198610
198710
198810
198930
199110
199220
199320
199460
199570
199671
199790
1998133
1999160
2000141
2001130
2002170
200390
2004111
200590
200620
200730
200930
201010
201110
201220
FIG. 1 — Lineage of K242519, 1995–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

7 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new IYN device

  1. #1 K240850 EPIQ Series Diagnostic Ultrasound Systems…score 32.1 · 24 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K192226Lumify Diagnostic Ultrasound System
Summary page 7
…uces the user’s responsibility for sound clinical judgement and best clinical procedure. 5. Substantially Equivalent Devices Predicate Device: K192226, Philips Ultrasound – Lumify Diagnostic Ultrasound System Primary Reference Device:…
Philips Health Care20195
†K120321Clearvue 350/550 Diagnostic Ultrasound SystemPhilips Health Care20128
†K240850EPIQ Series Diagnostic Ultrasound Systems; Affiniti Series Diagnostic Ultrasound SystemsPhilips Ultrasound, LLC2024—

Also cleared against K192226: 8 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (7 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Sep 24, 2026Class IZ-0152-2027Device DesignUltrasound system may: 1) Not recognize previous transducer registration, prevent scanning, require re-registration with Wi-Fi/cellular access, which may be unavailable outside of the hospital (ambulances/aircraft/field); 2) At connection…
Oct 31, 2025Class IIZ-0883-2026Software designUltrasound system compatibility issues with Apple devices running iOS 18 may cause a failure to perform live imagining.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K040050Instatrak System with Multiple Dataset Navigation, Model IT3500Ge Medical Systems Navigation and Visualization IN · 2004 · 8 generations back · ◆ in the 2004 ancestors bar of FIG. 11 Class I recall
  • K994270Instatrak 3000 System with Fluorotrak Module, Model IT3000Visualization Technology, Inc. · 2000 · 8 generations back · ◆ in the 2000 ancestors bar of FIG. 12 Class I recalls
  • K983529Instatrak 3000Visualization Technology, Inc. · 1998 · 8 generations back · ◆ in the 1998 ancestors bar of FIG. 11 Class I recall
  • K982994Skull Base Instatrak SystemVisualization Technology, Inc. · 1998 · 8 generations back · ◆ in the 1998 ancestors bar of FIG. 11 Class I recall
  • K981998Pediatric Instatrak SystemVisualization Technology, Inc. · 1998 · 8 generations back · ◆ in the 1998 ancestors bar of FIG. 11 Class I recall
  • K960330InstatrakVisualization Technology, Inc. · 1996 · 8 generations back · ◆ in the 1996 ancestors bar of FIG. 11 Class I recall

What does this lineage say?

  • The line of descent spans 30 years and passes through 8 companies; a new generation was cleared every 11 months on median.
  • 46 of the 175 ancestors have a recall of any class; 6 have a Class I recall.
  • 8 other devices also cite its predicate K192226.

How does its category compare?

All IYN devices

IYN System, Imaging, Pulsed Doppler, Ultrasonic: FDA decisions, review times, recalls and adverse event reports over 20 years. 2025, this device’s year, is highlighted.

FDA decisions per year · IYN

57in 2025

2007: 132008: 252009: 182010: 292011: 392012: 432013: 512014: 562015: 542016: 602017: 642018: 592019: 472020: 572021: 462022: 532023: 442024: 502025: 572026 (partial year): 44
2007high 64 (2017) · low 13 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · IYN

124in 2025

2007: 26 days median2008: 18 days median2009: 29 days median2010: 67 days median2011: 46 days median2012: 37 days median2013: 60 days median2014: 39 days median2015: 55 days median2016: 56 days median2017: 83 days median2018: 85 days median2019: 79 days median2020: 72 days median2021: 105 days median2022: 105 days median2023: 115 days median2024: 119 days median2025: 124 days median2026 (partial year): 107 days median
2007high 124 (2025) · low 18 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · IYN

10in 2025

2007: 162008: 122009: 82010: 102011: 82012: 32013: 82014: 22015: 32016: 22018: 72020: 42021: 82022: 102023: 42024: 12025: 102026 (partial year): 2, 1 Class I
2007high 16 (2007) · low 0 (2017)2026

Class I (1 since 2007) Class II/III not classified

Adverse event reports per year · IYN

610in 2025

2007: 32008: 22009: 92010: 172011: 182012: 202013: 182014: 482015: 1162016: 1452017: 1462018: 852019: 592020: 672021: 2132022: 1862023: 2292024: 2662025: 610
2007high 610 (2025) · low 2 (2008)2025

MAUDE reports naming product code IYN, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071326163
20082518122
2009182989
201029671017
20113946818
20124337320
20135160818
20145639248
201554553116
201660562145
201764830146
20185985785
20194779059
20205772467
2021461058213
20225310510186
2023441154229
2024501191266
20255712410610
2026441072 (1)—

What is it indicated for?

The Philips Lumify Diagnostic Ultrasound System is intended for diagnostic ultrasound imaging in B (2D), Color Doppler, Combined (B+Color), Pulsed Wave Doppler (PWD), and M-modes.

It is indicated for diagnostic ultrasound imaging and fluid flow analysis in the following applications:

Fetal/Obstetric, Abdominal, Pediatric, Cephalic, Urology, Gynecological, Cardiac Fetal Echo, Small Organ, Musculoskeletal, Peripheral Vessel, Carotid, Cardiac, Lung, Trans-vaginal.

The Lumify system is a transportable ultrasound system intended for use in environments where healthcare is provided by appropriately trained healthcare professionals.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K242519: Lumify Diagnostic Ultrasound System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 3, 2026. https://510kreport.com/device/K242519

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026