510(k) · Cleared
ClearedPancreatic Drainage Tube
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Aomori Olympus Co., Ltd. · FGE Stents, Drains And Dilators For The Biliary Ducts
Cleared on Apr 16, 2003 as substantially equivalent to K933200 (Olympus Corp., 1995) and 1 other predicate after a 330-day review. Its family tree reaches back 1 generation to 1990.
- Decided
- Apr 16, 2003
- Review
- 330 days
- Class
- Class II
- Product code
- FGE
- Recalls
- None
- Predicates
- 2
Its longest line of descent runs back 1 generation to K900923 (1990). 2 ancestors in all. No later device cites it as a predicate yet.
- Root · 1 generation backK900923 Zimmon Endoscopic Pancreatic StentWilson-Cook Medical, Inc. · 1990
- This deviceK021672 Pancreatic Drainage TubeAomori Olympus Co., Ltd. · 2003
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −1 | K900923 | Zimmon Endoscopic Pancreatic Stent | Wilson-Cook Medical, Inc. | 1990 | — |
| 0 (this device) | K021672 | Pancreatic Drainage Tube | Aomori Olympus Co., Ltd. | 2003 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1995 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in FGE? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new FGE device
- #1 K240464 WallFlex Biliary RX Stent System; Epic Biliary…score 14.5 · 13 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (2)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K933200 | Olympus PBD StentsSummary page 1….5010 Biliary catheter and accessories 21CFR #876.1500 Endoscope and accessories Predicate Device: Olympus PBD Stents #IC933200 Zimmon Endoscopic Pancreatic Stent (IC900923 Wilson-Cook Me… | 1995 |
| * | K900923 | Zimmon Endoscopic Pancreatic StentSummary page 1…Predicate Device: Olympus PBD Stents #IC933200 Zimmon Endoscopic Pancreatic Stent (IC900923 Wilson-Cook Medical, Inc.) KO2 16;’Z… | 1990 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- 1 of the 2 ancestors has a recall of any class.
- 2 other devices also cite its predicate K933200.
How does its category compare?
All FGE devicesFGE Stents, Drains And Dilators For The Biliary Ducts: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · FGE
7in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · FGE
257in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · FGE
1in 2024
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · FGE
1,923in 2025
MAUDE reports naming product code FGE, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 4 | 316 | 54 | 1,006 |
| 2008 | 11 | 214 | 93 | 1,465 |
| 2009 | 7 | 160 | 18 | 1,655 |
| 2010 | 9 | 81 | 32 | 1,434 |
| 2011 | 9 | 114 | 2 | 1,321 |
| 2012 | 8 | 96 | 4 | 1,183 |
| 2013 | 5 | 161 | 3 | 1,060 |
| 2014 | 8 | 156 | 0 | 1,270 |
| 2015 | 8 | 79 | 0 | 1,543 |
| 2016 | 4 | 49 | 0 | 1,453 |
| 2017 | 9 | 59 | 1 | 1,515 |
| 2018 | 7 | 215 | 43 | 1,681 |
| 2019 | 2 | — | 13 | 1,896 |
| 2020 | 4 | 121 | 1 | 2,182 |
| 2021 | 1 | — | 27 | 2,297 |
| 2022 | 6 | 101 | 21 | 1,749 |
| 2023 | 6 | 199 | 19 | 1,615 |
| 2024 | 6 | 188 | 1 | 1,948 |
| 2025 | 7 | 257 | 0 | 1,923 |
| 2026 | 8 | 153 | 11 | — |
What is it indicated for?
This instrument has been designed to be used with Olyinpus endoscopes for Endoscopic Pancreatic Drainage. The Drainage Tube is not intended to be permanently implanted in the patient. The Drainage Tube is intended for short-term implantation. The Drainage Tube is also available as a kit, which includes accessories to aid in the placement of the Drainage Tube.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K021672 · printed Nov 6, 2026
Cite this page
510(k) Report. “K021672: Pancreatic Drainage Tube.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K021672
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026