Recalled · Class II · 2026IQ 200 System
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Intl. Remote Imaging Systems · LKM Counter, Urine Particle
Cleared on Oct 21, 2002 after a 61-day review. The FDA summary names its predicate without a number. 3 later devices descend from it. It has been recalled 14 times.
- Decided
- Oct 21, 2002
- Review
- 61 days
- Class
- Class II
- Product code
- LKM
- Recalls
- 14
- Predicates
- 0
3 later devices descend from it, 3 citing it directly.
- This deviceK022774 IQ 200 SystemIntl. Remote Imaging Systems · 2002
- Descendant · cites it directly · 1 of its ownK210127 iQ200 System, iChemVELOCITY Automated Urine Chemistry SystemBeckman Coulter, Inc. · 2021 · Recalled
- Descendant · cites it directly · 0 of its ownK252580 iQ200 SeriesBeckman Coulter, Inc. · 2025 · Recalled
- Descendant · cites it directly · 0 of its ownK200811 cobas u 701 microscopy analyzerRoche Diagnostics · 2020
Most influential descendants
Showing 3 of 3 · See allView FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| 0 (this device) | K022774 | IQ 200 System | Intl. Remote Imaging Systems | 2002 | — |
| +1 | K210127 | iQ200 System, iChemVELOCITY Automated Urine Chemistry System | Beckman Coulter, Inc. | 2021 | 6 |
| +1 | K252580 | iQ200 Series | Beckman Coulter, Inc. | 2025 | 2 |
| +1 | K200811 | cobas u 701 microscopy analyzer | Roche Diagnostics | 2020 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2020 | 1 | 0 |
| 2021 | 1 | 0 |
| 2025 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in LKM? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new LKM device
- #1 K252580 iQ200 Seriesscore 9.5 · 6 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (5)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | — | The Yellow IRIS Urinalysis Workstation with CHEMSTRIP Reader Named without a submission number | |
| * | — | IRIS Flow Microscope Named without a submission number | |
| * | — | 900UDx Urine Pathology System Named without a submission number | |
| * | — | 939UDx Urine Pathology System Named without a submission number | |
| * | — | Sysmex UF-100 Named without a submission number |
What descends from it? (3)
3 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
Recalls of this device
| Date | Class | Recall | Root cause | Reason |
|---|---|---|---|---|
| Aug 12, 2026 | Class II | Z-0161-2027 | Component design/selection | The rinse-line check valve has a shorter service lifespan than originally expected and requires annual replacement to prevent lamina fluid leakage; however, the check valve replacement was excluded from the annual preventive maintenance… |
| Aug 12, 2026 | Class II | Z-0160-2027 | Component design/selection | The rinse-line check valve has a shorter service lifespan than originally expected and requires annual replacement to prevent lamina fluid leakage; however, the check valve replacement was excluded from the annual preventive maintenance… |
| Dec 19, 2023 | Class II | Z-0784-2024 | Other | Beckman Coulter has become aware that the cannula, which is found in the Flowcell and the iQClear Rinse Waste Well Assembly, may rust. Rust from the cannula has the potential to generate erroneous results. |
| Dec 19, 2023 | Class II | Z-0787-2024 | Other | Beckman Coulter has become aware that the cannula, which is found in the Flowcell and the iQClear Rinse Waste Well Assembly, may rust. Rust from the cannula has the potential to generate erroneous results. |
| Dec 19, 2023 | Class II | Z-0786-2024 | Other | Beckman Coulter has become aware that the cannula, which is found in the Flowcell and the iQClear Rinse Waste Well Assembly, may rust. Rust from the cannula has the potential to generate erroneous results. |
| Dec 19, 2023 | Class II | Z-0785-2024 | Other | Beckman Coulter has become aware that the cannula, which is found in the Flowcell and the iQClear Rinse Waste Well Assembly, may rust. Rust from the cannula has the potential to generate erroneous results. |
| Apr 5, 2023 | Class II | Z-1597-2023 | Under Investigation by firm | Beckman Coulter has become aware of an intermittent issue in which the optional flag "Previous Sample Had Sperm" was enabled but not displayed so that a carryover event could have been investigated. |
| Apr 5, 2023 | Class II | Z-1599-2023 | Under Investigation by firm | Beckman Coulter has become aware of an intermittent issue in which the optional flag "Previous Sample Had Sperm" was enabled but not displayed so that a carryover event could have been investigated. |
| Apr 5, 2023 | Class II | Z-1596-2023 | Under Investigation by firm | Beckman Coulter has become aware of an intermittent issue in which the optional flag Previous Sample Had Sperm was enabled but not displayed so that a carryover event could have been investigated. |
| Apr 5, 2023 | Class II | Z-1598-2023 | Under Investigation by firm | Beckman Coulter has become aware of an intermittent issue in which the optional flag "Previous Sample Had Sperm" was enabled but not displayed so that a carryover event could have been investigated. |
| Mar 30, 2020 | Class II | Z-1945-2020 | Nonconforming Material/Component | A defect in the SATA power adapter cable within the instrument s computer has the potential risk for an electrical short that may lead to the following outcomes: charring and/or melting of the SATA adapter cable within the computer s… |
| Oct 28, 2019 | Class II | Z-0914-2020 | Software in the Use Environment | Customers have reported incidents where two sets of results report the same Specimen Identifier (Specimen ID) with different results, different Medical Record Number (MRN) and different patient identification (demographics). |
| Mar 2, 2018 | Class II | Z-1362-2018 | Use error | Beckman Coulter has determined that there is a potential for under-reporting casts. This can occur if per high-power field (/HPF) units of measurement for casts are selected in the iQ200 software, but the abnormal threshold and/or grading… |
| Nov 10, 2017 | Class II | Z-1366-2018 | Device Design | iQ200 Series Urine Microscopy Analyzer may intermittently fail to read urine sample dilution barcode labels causing erroneous results that could delay treatment for health conditions such as hematuria. |
The 5 latest of 14 recalls; the web page lists all.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Of its descendants, K210127 (Beckman Coulter, Inc., 2021) has gone furthest, with 1 descendant of its own.
How does its category compare?
All LKM devicesLKM Counter, Urine Particle: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · LKM
1in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · LKM
Too few LKM 510(k)s in any year since 2007 to give a median.
Recalls per year · LKM
4in 2023
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · LKM
1in 2021
MAUDE reports naming product code LKM, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 1 | — | 0 | 0 |
| 2008 | 1 | — | 0 | 0 |
| 2009 | 1 | — | 0 | 0 |
| 2010 | 1 | — | 0 | 0 |
| 2011 | 0 | — | 0 | 0 |
| 2012 | 0 | — | 0 | 0 |
| 2013 | 0 | — | 1 | 3 |
| 2014 | 0 | — | 0 | 1 |
| 2015 | 0 | — | 0 | 0 |
| 2016 | 0 | — | 0 | 3 |
| 2017 | 0 | — | 0 | 1 |
| 2018 | 1 | — | 0 | 0 |
| 2019 | 0 | — | 1 | 2 |
| 2020 | 1 | — | 0 | 2 |
| 2021 | 1 | — | 0 | 1 |
| 2022 | 0 | — | 0 | 0 |
| 2023 | 0 | — | 4 | 0 |
| 2024 | 1 | — | 0 | 0 |
| 2025 | 1 | — | 0 | 0 |
| 2026 | 0 | — | 0 | — |
What is it indicated for?
The iQ 200 System is intended for analysis of urine chemistry, specific gravity, and formed sediment elements, which constitutes typical routine urinalysis. Urinalysis is ordered by physicians as a screening procedure for detection of possible abnormal metabolic or systemic disease, indicated by chemical composition of urine, and of potential renal or urinary tract disease or dysfunction, indicated by urine concentration and by the nature and…
Read the full statement (199 words)
The iQ 200 System is intended for analysis of urine chemistry, specific gravity, and formed sediment elements, which constitutes typical routine urinalysis.
Urinalysis is ordered by physicians as a screening procedure for detection of possible abnormal metabolic or systemic disease, indicated by chemical composition of urine, and of potential renal or urinary tract disease or dysfunction, indicated by urine concentration and by the nature and distribution of urinary formed elements. Urine profile testing is commonly employed in the initial clinical evaluation of patients admitted for hospital care or undergoing physical examinations.
Routine urinalysis is also indicated in diagnosis of patients with possible renal or urinary tract infection, carcinoma, or other injury, as well as for monitoring the status and effectiveness of drug, radiation, or dietary therapy, and of post-surgical or post-therapeutic recovery.
The information produced by the iQ 200 System concerning the composition of patient urines is ordered at the discretion of the physician, and is part of a larger body of laboratory and other test results available to assist the physician in health assessments or differential diagnoses. Routine urinalysis findings are always subject to judgment and interpretation by physicians relative to the patient's overall clinical presentation and history.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K022774 · printed Nov 6, 2026
Cite this page
510(k) Report. “K022774: IQ 200 System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K022774
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026