510(k) · Cleared
ClearedSoaker Catheter
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
I-Flow Corp. · FRN Pump, Infusion
Cleared on Sep 20, 2002 as substantially equivalent to K991543 (I-Flow Corp., 1999) and 1 other predicate after a 22-day review. Its family tree reaches back 3 generations to 1981. 12 later devices descend from it.
- Decided
- Sep 20, 2002
- Review
- 22 days
- Class
- Class II
- Product code
- FRN
- Recalls
- None
- Predicates
- 2
Its longest line of descent runs back 3 generations to K813186 (1981). 5 ancestors in all. 12 later devices descend from it, 2 citing it directly.
- Root · 3 generations backK813186 Perfix Set for Epidural Anesthesia W/TuoBurron Medical Products, Inc. · 1981
- 2 generations backK991543 Intraop CatheterI-Flow Corp. · 1999
- 1 generation backK994374 Soaker CatheterI-Flow Corp. · 2000
- This deviceK022869 Soaker CatheterI-Flow Corp. · 2002
- Descendant · cites it directly · 11 of its ownK043456 Modification to Soaker CatheterI-Flow Corp. · 2005
- Descendant · 2 generations on · 4 of its ownK143164 ON-Q Pain Relief System, QuikBloc Over-the-Needle Catheter SetKimberly-Clark Corporation · 2014
- Descendant · 2 generations on · 4 of its ownK051401 ON-Q Catheter, on-Antimicrobial Catheter, Soaker Catheter, I-Flow…I-Flow Corp. · 2005
- Descendant · cites it directly · 2 of its ownK080675 Pajunk Infiltralong Wound Infiltration Catheter KitPAJUNK GmbH Medizintechnologie · 2008
- Descendant · 3 generations on · 1 of its ownK152952 E-CathPAJUNK GmbH Medizintechnologie · 2016
Showing 5 of 12 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 12 · See all- K043456Modification to Soaker CatheterI-Flow Corp. · 2005 · cites it directly11descendants
- K143164ON-Q Pain Relief System, QuikBloc Over-the-Needle Catheter SetKimberly-Clark Corporation · 2014 · 2 generations on4descendants
- K051401ON-Q Catheter, on-Antimicrobial Catheter, Soaker Catheter, I-Flow CatheterI-Flow Corp. · 2005 · 2 generations on4descendants
- K080675Pajunk Infiltralong Wound Infiltration Catheter KitPAJUNK GmbH Medizintechnologie · 2008 · cites it directly2descendants
- K152952E-CathPAJUNK GmbH Medizintechnologie · 2016 · 3 generations on1descendant
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −3 | K813186 | Perfix Set for Epidural Anesthesia W/Tuo | Burron Medical Products, Inc. | 1981 | — |
| −2 | K991543 | Intraop Catheter | I-Flow Corp. | 1999 | — |
| −1 | K994374 | Soaker Catheter | I-Flow Corp. | 2000 | — |
| 0 (this device) | K022869 | Soaker Catheter | I-Flow Corp. | 2002 | — |
| +1 | K043456 | Modification to Soaker Catheter | I-Flow Corp. | 2005 | — |
| +2 | K143164 | ON-Q Pain Relief System, QuikBloc Over-the-Needle Catheter Set | Kimberly-Clark Corporation | 2014 | — |
| +2 | K051401 | ON-Q Catheter, on-Antimicrobial Catheter, Soaker Catheter, I-Flow Catheter | I-Flow Corp. | 2005 | — |
| +1 | K080675 | Pajunk Infiltralong Wound Infiltration Catheter Kit | PAJUNK GmbH Medizintechnologie | 2008 | — |
| +3 | K152952 | E-Cath | PAJUNK GmbH Medizintechnologie | 2016 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1984 | 1 | 0 |
| 1998 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2005 | 2 | 0 |
| 2006 | 1 | 0 |
| 2008 | 2 | 0 |
| 2011 | 1 | 0 |
| 2014 | 1 | 0 |
| 2016 | 2 | 0 |
| 2017 | 1 | 0 |
| 2020 | 2 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in FRN? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new FRN device
- #1 K253703 RemunityPRO+ Pump for Remodulin®…score 12.6 · 4 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (2)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K991543 | Intraop CatheterSummary page 1…e Name: Soaker Catheter Common Name: Anesthetic Catheter Classification Name: Anesthesia Conduction Catheter Existing Device: Soaker Catheter (K991543 and K994374) Device Description: The Soaker Catheter has a closed end tip with multiple holes arranged r… | 1999 |
| * | K994374 | Soaker CatheterSummary page 1…Soaker Catheter Common Name: Anesthetic Catheter Classification Name: Anesthesia Conduction Catheter Existing Device: Soaker Catheter (K991543 and K994374) Device Description: The Soaker Catheter has a closed end tip with multiple holes arranged radially alon… | 2000 |
What descends from it? (12)
See all 122 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 21 years and passes through 2 companies; a new generation was cleared every 2.5 years on median.
- 1 of the 5 ancestors has a recall of any class.
- Of its descendants, K043456 (I-Flow Corp., 2005) has gone furthest, with 11 descendants of its own.
- 4 other devices also cite its predicate K991543.
How does its category compare?
All FRN devicesFRN Pump, Infusion: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · FRN
8in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · FRN
172in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · FRN
7in 2025
Class I (37 since 2007) Class II/III not classified
Adverse event reports per year · FRN
52,792in 2025
MAUDE reports naming product code FRN, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 12 | 102 | 15 | 1,086 |
| 2008 | 8 | 89 | 24 | 8,261 |
| 2009 | 9 | 66 | 102 | 1,952 |
| 2010 | 3 | 93 | 37 | 6,133 |
| 2011 | 3 | 103 | 69 | 41,367 |
| 2012 | 4 | 217 | 42 (2) | 15,482 |
| 2013 | 6 | 312 | 22 (3) | 40,082 |
| 2014 | 6 | 172 | 4 (3) | 94,180 |
| 2015 | 3 | 232 | 5 | 26,742 |
| 2016 | 3 | 301 | 7 (1) | 16,560 |
| 2017 | 3 | 305 | 13 | 12,060 |
| 2018 | 3 | 267 | 1 | 16,591 |
| 2019 | 2 | — | 18 (1) | 15,850 |
| 2020 | 1 | — | 16 (5) | 94,186 |
| 2021 | 2 | — | 3 (2) | 199,342 |
| 2022 | 6 | 268 | 2 | 888,020 |
| 2023 | 7 | 265 | 16 (10) | 165,838 |
| 2024 | 5 | 103 | 9 (4) | 57,730 |
| 2025 | 8 | 172 | 7 (4) | 52,792 |
| 2026 | 2 | — | 11 (2) | — |
What is it indicated for?
1. With I-Flow Corporation’s PainBuster, ON-Q and Nerve Block pain management kits; and
2. As a stand alone device to provide continuous or intermittent delivery of local anesthetics or narcotics to surgical wound sites and/or close proximity to nerves outside of the epidural space. Routes of administration may be intraoperative, percutaneous or perineural.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K022869 · printed Nov 5, 2026
Cite this page
510(k) Report. “K022869: Soaker Catheter.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K022869
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026