510(k) · Cleared
ClearedBilirubin-SL (Total) Assay, Model 284-10/30
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Diagnostic Chemicals, Ltd. · CIG Diazo Colorimetry, Bilirubin
Cleared on Dec 11, 2002 after a 68-day review. The FDA summary names no predicate by number.
- Decided
- Dec 11, 2002
- Review
- 68 days
- Class
- Class II
- Product code
- CIG
- Recalls
- None
- Predicates
- 0
The FDA summary names no predicate by number.
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in CIG? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new CIG device
- #1 K251998 Atellica CH Diazo Total Bilirubin (D_TBil)score 11.8 · 4 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against?
The FDA summary names no predicate by number.
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
How does its category compare?
All CIG devicesCIG Diazo Colorimetry, Bilirubin: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · CIG
2in 2023
2026 to Oct 25, outlined.
Median 510(k) review, days · CIG
64in 2013
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · CIG
1in 2019
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · CIG
52in 2025
MAUDE reports naming product code CIG, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 1 | — | 0 | 2 |
| 2008 | 3 | 199 | 0 | 8 |
| 2009 | 2 | — | 3 | 3 |
| 2010 | 1 | — | 0 | 6 |
| 2011 | 2 | — | 0 | 38 |
| 2012 | 0 | — | 0 | 14 |
| 2013 | 5 | 64 | 3 | 8 |
| 2014 | 0 | — | 0 | 3 |
| 2015 | 1 | — | 0 | 7 |
| 2016 | 0 | — | 0 | 4 |
| 2017 | 1 | — | 0 | 11 |
| 2018 | 0 | — | 0 | 23 |
| 2019 | 1 | — | 1 | 25 |
| 2020 | 0 | — | 0 | 31 |
| 2021 | 0 | — | 0 | 22 |
| 2022 | 1 | — | 0 | 26 |
| 2023 | 2 | — | 0 | 34 |
| 2024 | 0 | — | 0 | 39 |
| 2025 | 0 | — | 0 | 52 |
| 2026 | 1 | — | 0 | — |
What is it indicated for?
Bilirubin is a bile pigment normally found in serum as a result of red cell destruction. It is a product of hemoglobin breakdown by the reticuloendothelial system and exists in two forms. Unconjugated (indirect) bilirubin is transported to the liver bound by albumin where it becomes conjugated (direct) with glucuronic acid and excreted.
The elevation of total serum bilirubin may occur due to hemolyhc processes, liver disease, or a disorder of the biliary tract.
For the quantitative determination of Bilirubin (Total) in serum. For IN VITRO diagnostic use.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K023330 · printed Nov 6, 2026
Cite this page
510(k) Report. “K023330: Bilirubin-SL (Total) Assay, Model 284-10/30.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K023330
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Page last updated Nov 3, 2026