510(k) Report

510(k) · Cleared

Cleared

Evergreen Non-Sterile Powdered Natural or Colored Latex Examination Glove

K024355510(k) TraditionalCleared Feb 3, 200335-day reviewClass I21 CFR 880.6250

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Yty Industry (Manjung) Sdn Bhd · LYY Latex Patient Examination Glove

Cleared on Feb 3, 2003 as substantially equivalent to K943807 (Shield Gloves Manufacturer (M) Sdn Bhd, 1994) and 2 other predicates after a 35-day review. Its family tree reaches back 2 generations to 1994.

Decided
Feb 3, 2003
Review
35 days
Class
Class I
Product code
LYY
Recalls
None
Predicates
3

Its longest line of descent runs back 2 generations to K943807 (1994). 3 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 2 generations backK943807 Royal Shield Pink Colored Non-Sterile Latex Examination GloveShield Gloves Manufacturer (M) Sdn Bhd · 1994
  2. 1 generation backK023590 Powdered Natural and/or Colored Latex Exam GlovesYty Industry (Manjung) Sdn Bhd · 2002
  3. This deviceK024355 Evergreen Non-Sterile Powdered Natural or Colored Latex Examination…Yty Industry (Manjung) Sdn Bhd · 2003
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K943807Royal Shield Pink Colored Non-Sterile Latex Examination GloveShield Gloves Manufacturer (M) Sdn Bhd1994—
−1K023590Powdered Natural and/or Colored Latex Exam GlovesYty Industry (Manjung) Sdn Bhd2002—
0 (this device)K024355Evergreen Non-Sterile Powdered Natural or Colored Latex Examination GloveYty Industry (Manjung) Sdn Bhd2003—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199710
FIG. 1 — Lineage of K024355, 1994–2003Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in LYY? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LYY device

  1. #1 K202377 Palm Care Latex Examination Powder Free Glovesscore 12.7 · 2 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K943807Royal Shield Pink Colored Non-Sterile Latex Examination Glove
Summary page 3
…Primary Skin Irritation Conclusion: This device is substantially equivalent to the devices approved as K943807, K974191 and K023590. DEPARTMENT OF HEALTH & HUMAN SERVICES Public Health Ser…
Shield Gloves Manufacturer (M) Sdn Bhd1994—
*K974191Evergreen Non-Sterile Powdered Latex Examination Glove
Summary page 3
…Primary Skin Irritation Conclusion: This device is substantially equivalent to the devices approved as K943807, K974191 and K023590. DEPARTMENT OF HEALTH & HUMAN SERVICES Public Health Service…
Yty Industry (Manjung) Sdn Bhd1997—
*K023590Powdered Natural and/or Colored Latex Exam Gloves
Summary page 3
…Primary Skin Irritation Conclusion: This device is substantially equivalent to the devices approved as K943807, K974191 and K023590. DEPARTMENT OF HEALTH & HUMAN SERVICES Public Health Service…
Yty Industry (Manjung) Sdn Bhd2002—

Also cleared against K943807: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 9 years and passes through 2 companies; a new generation was cleared every 8.1 years on median.
  • None of the 3 ancestors has a recall.
  • 1 other device also cites its predicate K943807.

How does its category compare?

All LYY devices

LYY Latex Patient Examination Glove: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · LYY

1in 2025

2007: 122008: 132009: 72010: 132011: 112012: 112013: 62014: 32015: 32016: 42017: 42018: 22019: 12020: 12021: 82022: 142023: 22024: 12025: 1
2007high 14 (2022) · low 1 (2019)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LYY

150in 2022

2007: 75 days median2008: 151 days median2009: 76 days median2010: 106 days median2011: 127 days median2012: 133 days median2013: 131 days median2014: 156 days median2015: 251 days median2016: 142 days median2017: 230 days median2021: 188 days median2022: 150 days median
2007high 251 (2015) · low 75 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · LYY

1in 2020

2011: 12020: 1
2007high 1 (2011) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · LYY

1in 2025

2007: 112008: 142009: 112010: 102011: 42012: 12013: 22014: 62015: 52016: 72017: 72019: 72020: 12021: 12024: 62025: 1
2007high 14 (2008) · low 0 (2018)2025

MAUDE reports naming product code LYY, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071275011
200813151014
2009776011
201013106010
20111112714
20121113301
2013613102
2014315606
2015325105
2016414207
2017423007
20182—00
20191—07
20201—11
2021818801
20221415000
20232—00
20241—06
20251—01
20260—0—

What is it indicated for?

This is a medical glove to be worn on the hand of health care and similar personnel to prevent

contamination between health care personnel and the patient.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K024355: Evergreen Non-Sterile Powdered Natural or Colored Latex Examination Glove.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K024355

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026