510(k) Report

510(k) · Cleared

Cleared

Cardiacassist Transseptal Cannula Set, Model 5132-6221

K030398510(k) TraditionalCleared May 23, 2003106-day reviewClass II21 CFR 870.1300

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Cardiacassist, Inc. · DQR Cannula, Catheter

Cleared on May 23, 2003 as substantially equivalent to K854511 (Electro-Catheter Corp., 1986) after a 106-day review. Its family tree reaches back 1 generation to 1986. 2 of the 12 devices in its family, counting itself, have a Class I recall. 10 later devices descend from it.

Decided
May 23, 2003
Review
106 days
Class
Class II
Product code
DQR
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to K854511 (1986). 10 later devices descend from it, 2 citing it directly. 2 of the 12 devices in this family, counting this one, have a Class I recall.

Descendants, by year cleared 2006: 1 descendant cleared2008: 2 descendants cleared2009: 1 descendant cleared2012: 1 descendant cleared2010: 1 descendant cleared2011: 2 descendants cleared, 1 with a Class I recall12013: 1 descendant cleared2014: 1 descendant cleared, 1 with a Class I recall1K854511 · Elecath Percutaneous Left Atrial Cannulation Set · Electro-Catheter Corp. · 19861990200020102020
Descendants, by generation 1 generation forward: 2 descendants2 generations forward: 1 descendant3 generations forward: 3 descendants4 generations forward: 2 descendants, 1 with a Class I recall15 generations forward: 2 descendants, 1 with a Class I recall1 K854511 · Elecath Percutaneous Left Atrial Cannulation Set · Electro-Catheter Corp. · 19860+5
  1. Root · 1 generation backK854511 Elecath Percutaneous Left Atrial Cannulation SetElectro-Catheter Corp. · 1986
  2. This deviceK030398 Cardiacassist Transseptal Cannula Set, Model 5132-6221Cardiacassist, Inc. · 2003
  3. Descendant · cites it directly · 9 of its ownK052570 Tandemheart Transseptal Cannula Set-EF, Model 5140-6221Cardiacassist, Inc. · 2006 · Recalled
  4. Descendant · 2 generations on · 7 of its ownK063723 Impella Recover LP 2.5 Percutaneous Cardiac Support SystemAbiomed, Inc. · 2008
  5. Descendant · 3 generations on · 3 of its ownK083111 Impella 5.0 Catheter FamilyAbiomed, Inc. · 2009 · Recalled
  6. Descendant · 4 generations on · 2 of its ownK102726 Cardiohelp SystemMaquet Cardiopulmonary, AG · 2011 · Recalled (Class I)
  7. Descendant · 3 generations on · 1 of its ownK093801 Impella ControllerAbiomed, Inc. · 2010

Showing 5 of 10 descendants. See all descendants

Descendants cleared per year

2006: 12008: 22009: 12010: 12011: 22012: 12013: 12014: 1
2006high 2 (2008) · low 0 (2007)2026

Class I recalls in this family

Most influential descendants

Showing 5 of 10 · See all
  • K052570Tandemheart Transseptal Cannula Set-EF, Model 5140-6221Cardiacassist, Inc. · 2006 · cites it directly9descendants
  • K063723Impella Recover LP 2.5 Percutaneous Cardiac Support SystemAbiomed, Inc. · 2008 · 2 generations on7descendants
  • K083111Impella 5.0 Catheter FamilyAbiomed, Inc. · 2009 · 3 generations on3descendants
  • K102726Cardiohelp SystemMaquet Cardiopulmonary, AG · 2011 · 4 generations on2descendants
  • K093801Impella ControllerAbiomed, Inc. · 2010 · 3 generations on1descendant
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K854511Elecath Percutaneous Left Atrial Cannulation SetElectro-Catheter Corp.1986—
0 (this device)K030398Cardiacassist Transseptal Cannula Set, Model 5132-6221Cardiacassist, Inc.2003—
+1K052570Tandemheart Transseptal Cannula Set-EF, Model 5140-6221Cardiacassist, Inc.20061
+2K063723Impella Recover LP 2.5 Percutaneous Cardiac Support SystemAbiomed, Inc.2008—
+3K083111Impella 5.0 Catheter FamilyAbiomed, Inc.20091
+4K102726Cardiohelp SystemMaquet Cardiopulmonary, AG2011Class I
+3K093801Impella ControllerAbiomed, Inc.2010—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200610
200820
200910
201010
201121
201210
201310
201411
FIG. 1 — Lineage of K030398, 1986–2014Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

2 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K854511Elecath Percutaneous Left Atrial Cannulation Set
Summary page 1
…sist-Transseptal Cannula Set Common Name: Transseptal Cannula Classification Name: Catheter Cannula Predicate Device Elecath Percutaneous Left Atrial Cannulation Set (K8545 11) Device Description The Transseptal Cannula Set consists of three components: (1) 2 1 Fr. Transseptal Cannula, (2) -…
Electro-Catheter Corp.1986—

What descends from it? (10)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K052570Tandemheart Transseptal Cannula Set-EF, Model 5140-6221Cardiacassist, Inc.20069
K082425Tandemheart Transseptal Cannula- EF 72Cardiacassist, Inc.20080

Has anything in its family been recalled? (2 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K102726Cardiohelp SystemMaquet Cardiopulmonary, AG · 2011 · 4 generations on · ◆ in the 2011 descendants bar of FIG. 11 Class I recall
  • K133598Cardiohelp SystemMaquet Cardiopulmonary, AG · 2014 · 5 generations on · ◆ in the 2014 descendants bar of FIG. 11 Class I recall

What does this lineage say?

  • Its one ancestor has no recall.
  • Of its descendants, K052570 (Cardiacassist, Inc., 2006) has gone furthest, with 9 descendants of its own.

How does its category compare?

All DQR devices

DQR Cannula, Catheter: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · DQR

1in 2013

2008: 12013: 1
2007high 1 (2008) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DQR

Too few DQR 510(k)s in any year since 2007 to give a median.

Recalls per year · DQR

1in 2020

2020: 1
2007high 1 (2020) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · DQR

6in 2025

2007: 172008: 82009: 272010: 242011: 72012: 72013: 62014: 82015: 402016: 752017: 292018: 172019: 162020: 42021: 112022: 272023: 362024: 72025: 6
2007high 75 (2016) · low 4 (2020)2025

MAUDE reports naming product code DQR, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—017
20081—08
20090—027
20100—024
20110—07
20120—07
20131—06
20140—08
20150—040
20160—075
20170—029
20180—017
20190—016
20200—14
20210—011
20220—027
20230—036
20240—07
20250—06
20260—0—

What is it indicated for?

The CardiacAssist Transseptal Cannula Set is intended for transseptal catheterization of the left atrium via the femoral vein for the purpose of providing a means for temporary (six hours or less) left ventricular bypass when connected to a suitable extracorporeal blood pump unit which returns blood to the patient via the femoral artery or other appropriate site.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K030398: Cardiacassist Transseptal Cannula Set, Model 5132-6221.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K030398

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026