510(k) · Cleared
ClearedEverstick Post
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Stick Tech, Ltd. · ELR Post, Root Canal
Cleared on May 20, 2003 as substantially equivalent to K011788 (Stick Tech, Ltd., 2001) and 1 other predicate after a 67-day review. Its family tree reaches back 2 generations to 2001. 1 later device descends from it.
- Decided
- May 20, 2003
- Review
- 67 days
- Class
- Class I
- Product code
- ELR
- Recalls
- None
- Predicates
- 2
Its longest line of descent runs back 2 generations to K003333 (2001). 3 ancestors in all, the oldest K913040 (1991). 1 later device descends from it, 1 citing it directly.
Most influential descendants
Showing 1 of 1 · See all- K060075Fiber-Metal PostForemost Dental, LLC · 2006 · cites it directly0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −2 | K003333 | STICK | Stick Tech, Ltd. | 2001 | — |
| −1 | K011788 | Everstick | Stick Tech, Ltd. | 2001 | — |
| 0 (this device) | K030820 | Everstick Post | Stick Tech, Ltd. | 2003 | — |
| +1 | K060075 | Fiber-Metal Post | Foremost Dental, LLC | 2006 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1991 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2006 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in ELR? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
- Candidate predicates for a device like this, rankedin the report
- Recall history across each candidate’s familyin the report
What was it cleared against? (2)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K011788 | Everstick | 2001 |
| * | K913040 | Ribbond (TM)Summary page 1…ement for dentistry everStickTMPOST is substantially equivalent to everStickTM,approved under 51O( k) number KO11788 dated November 7, 2001 and Ribbond, approved under K913040 dated October7, 1991. The composition of everStickTMPOST is equal with its predicate device, everStickTM with the same technolo… | 1991 |
What descends from it? (1)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K060075 | Fiber-Metal Post | 2006 | 0 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 2 years and passes through 1 company; a new generation was cleared every 1.5 years on median.
- None of the 3 ancestors has a recall.
- Of its descendants, K060075 (Foremost Dental, LLC, 2006) has gone furthest, with 0 descendants of its own.
- 7 other devices also cite its predicate K011788.
How does its category compare?
All ELR devicesELR Post, Root Canal: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · ELR
FDA has decided no ELR device since 2007.
Median 510(k) review, days · ELR
Too few ELR 510(k)s in any year since 2007 to give a median.
Recalls per year · ELR
1in 2018
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · ELR
1in 2025
MAUDE reports naming product code ELR, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 0 | — | 0 | 8 |
| 2008 | 0 | — | 0 | 5 |
| 2009 | 0 | — | 1 | 3 |
| 2010 | 0 | — | 0 | 1 |
| 2011 | 0 | — | 0 | 4 |
| 2012 | 0 | — | 0 | 13 |
| 2013 | 0 | — | 0 | 6 |
| 2014 | 0 | — | 0 | 30 |
| 2015 | 0 | — | 0 | 3 |
| 2016 | 0 | — | 0 | 8 |
| 2017 | 0 | — | 0 | 1 |
| 2018 | 0 | — | 1 | 5 |
| 2019 | 0 | — | 0 | 20 |
| 2020 | 0 | — | 0 | 2 |
| 2021 | 0 | — | 0 | 3 |
| 2022 | 0 | — | 0 | 2 |
| 2023 | 0 | — | 0 | 0 |
| 2024 | 0 | — | 0 | 1 |
| 2025 | 0 | — | 0 | 1 |
| 2026 | 0 | — | 0 | — |
What is it indicated for?
Intended for use as a fiber reinforced root canal post
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K030820 · printed Nov 6, 2026
Cite this page
510(k) Report. “K030820: Everstick Post.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K030820
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026