510(k) · Cleared
ClearedSpirosoft
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Viasys Healthcare GmbH · BTY Calculator, Predicted Values, Pulmonary Function
Cleared on Jul 30, 2003 after a 105-day review. FDA’s file for it is a 510(k) statement, which names no predicate.
- Decided
- Jul 30, 2003
- Review
- 105 days
- Class
- Class II
- Product code
- BTY
- Recalls
- None
- Predicates
- 0
FDA’s file for it is a 510(k) statement, which names no predicate.
Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in BTY? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new BTY device
- #1 K260242 CPETWise Platformscore 13.1 · 5 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against?
FDA’s file for it is a 510(k) statement, which names no predicate.
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
How does its category compare?
All BTY devicesBTY Calculator, Predicted Values, Pulmonary Function: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · BTY
3in 2024
2026 to Oct 25, outlined.
Median 510(k) review, days · BTY
266in 2024
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · BTY
2in 2017
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · BTY
5in 2024
MAUDE reports naming product code BTY, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 2 | — | 0 | 0 |
| 2008 | 3 | 104 | 0 | 0 |
| 2009 | 1 | — | 0 | 1 |
| 2010 | 1 | — | 0 | 0 |
| 2011 | 1 | — | 0 | 3 |
| 2012 | 3 | 139 | 0 | 2 |
| 2013 | 0 | — | 0 | 0 |
| 2014 | 0 | — | 1 | 1 |
| 2015 | 0 | — | 0 | 51 |
| 2016 | 1 | — | 0 | 24 |
| 2017 | 1 | — | 2 | 9 |
| 2018 | 0 | — | 0 | 5 |
| 2019 | 2 | — | 0 | 3 |
| 2020 | 1 | — | 0 | 3 |
| 2021 | 1 | — | 0 | 2 |
| 2022 | 1 | — | 0 | 2 |
| 2023 | 1 | — | 0 | 1 |
| 2024 | 3 | 266 | 0 | 5 |
| 2025 | 0 | — | 0 | 0 |
| 2026 | 1 | — | 0 | — |
What is it indicated for?
The SpiroSoft is a portable device and can be used by physicians in the office or hospital and in occupational medicine.
The SpiroSoft measures inspiratory and expiratory lung function parameter in adults and children from 4 years on according to the ATS recommendations for diagnostic devices.
Results are output graphicaly and numericaly on a screen and on an external printer. SpiroSoft saves all data in the internal memory for later retrieval or printout.
The following caution label appears on page 2 of the SpiroSoft Instruction Manual:
"Federal U.S. law restricts this device to sale by or on the order of a physician."
Indications for use as stated in the FDA 510(k) statement.
https://510kreport.com/device/K031194 · printed Nov 6, 2026
Cite this page
510(k) Report. “K031194: Spirosoft.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K031194
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Page last updated Nov 3, 2026