510(k) · Cleared
ClearedEbi P148 Spinal Fixation System
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Ebi, L.P. · MNH Orthosis, Spondylolisthesis Spinal Fixation
Cleared on Jun 27, 2003 after a 52-day review. The FDA summary names its predicate without a number.
- Decided
- Jun 27, 2003
- Review
- 52 days
- Class
- Class II
- Product code
- MNH
- Recalls
- None
- Predicates
- 0
The FDA summary names its predicate without a number.
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in MNH? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
- Candidate predicates for a device like this, rankedin the report
- Recall history across each candidate’s familyin the report
What was it cleared against? (2)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | — | EBI Omega 21 Spinal Fixation System Named without a submission number | |
| * | — | Webb-Morley Spine System Named without a submission number |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
How does its category compare?
All MNH devicesMNH Orthosis, Spondylolisthesis Spinal Fixation: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · MNH
8in 2016
2026 to Oct 25, outlined.
Median 510(k) review, days · MNH
93in 2016
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · MNH
1in 2016
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · MNH
89in 2025
MAUDE reports naming product code MNH, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 5 | 123 | 0 | 18 |
| 2008 | 13 | 65 | 0 | 30 |
| 2009 | 13 | 151 | 7 | 45 |
| 2010 | 10 | 106 | 0 | 59 |
| 2011 | 17 | 171 | 0 | 107 |
| 2012 | 7 | 93 | 1 | 433 |
| 2013 | 10 | 124 | 1 | 464 |
| 2014 | 12 | 140 | 0 | 286 |
| 2015 | 10 | 99 | 0 | 152 |
| 2016 | 8 | 93 | 1 | 216 |
| 2017 | 0 | — | 0 | 174 |
| 2018 | 0 | — | 0 | 129 |
| 2019 | 0 | — | 0 | 403 |
| 2020 | 0 | — | 0 | 432 |
| 2021 | 0 | — | 0 | 531 |
| 2022 | 0 | — | 0 | 265 |
| 2023 | 0 | — | 0 | 121 |
| 2024 | 0 | — | 0 | 302 |
| 2025 | 0 | — | 0 | 89 |
| 2026 | 0 | — | 0 | — |
What is it indicated for?
The EBI P148 Spinal Fixation System is a single use spinal fixation device for pedicle screw fixation and a non-pedicle hook and sacroiliac screw fixation system of the non-cervical spine. When used as a pedicle screw fixation system, in the non-cervical spine of skeletally mature patients, the System is intended to provide immobilization and stabilization of spinal segments, as an adjunct to fusion in the treatment of the following acute and chronic…
Read the full statement (336 words)
The EBI P148 Spinal Fixation System is a single use spinal fixation device for pedicle screw fixation and a non-pedicle hook and sacroiliac screw fixation system of the non-cervical spine.
When used as a pedicle screw fixation system, in the non-cervical spine of skeletally mature patients, the System is intended to provide immobilization and stabilization of spinal segments, as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities of the thoracic, lumbar, and sacral spine: degenerative disc disease (defined as discogenic back pain with degeneration of the disc confirmed by history and radiographic studies), degenerative spondylolisthesis with objective evidence of neurologic impairment, fracture, dislocations, scoliosis, kyphosis, spinal tumor, and failed previous fusion (pseudarthrosis).
In addition, when used as a pedicle screw fixation system in skeletally mature patients, it is intended for patients: (a) having severe spondylolisthesis (Grades 3 and 4) of the fifth lumbar - first sacral (L5 - S1) vertebral joint; (b) who are receiving fusions using autogenous bone graft only; (c) who are having the device fixed or attached to the lumbar and sacral spine (L3 and below); and (d) who are having the device removed after the development of a solid fusion mass.
When used as a posterior hook and sacroiliac screw fixation system, the levels of attachment are the lumbar and thoracic spine, and screw fixation is limited to the sacrum and ilium. The System is intended for the treatment of degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies); pseudarthrosis; stenosis; scoliosis; spondylolisthesis; fracture; previous failed fusion; or tumor resection.
When used as an anterior fixation system, the levels of attachment are the anterolateral vertebral bodies of the lumbar and thoracic spine. The System is intended for the treatment of degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies); pseudarthrosis; stenosis; scoliosis; spondylolisthesis; fracture; previous failed fusion; or tumor resection.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K031423 · printed Nov 6, 2026
Cite this page
510(k) Report. “K031423: Ebi P148 Spinal Fixation System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K031423
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Page last updated Nov 3, 2026