510(k) · Cleared
ClearedPyramis Ecg Management System Model Numbers, 92600 and 92601
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Quinton, Inc. · DQK Computer, Diagnostic, Programmable
Cleared on Sep 5, 2003 as substantially equivalent to K964784 (Quinton, Inc., 1997) after a 66-day review. Its family tree reaches back 2 generations to 1995. 20 later devices descend from it.
- Decided
- Sep 5, 2003
- Review
- 66 days
- Class
- Class II
- Product code
- DQK
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 2 generations to K945626 (1995). 20 later devices descend from it, 4 citing it directly.
- Root · 2 generations backK945626 Quinton Model 710 Stress ElectrocardiographQuinton, Inc. · 1995
- 1 generation backK964784 Synergy Cardiology Information System (00431)Quinton, Inc. · 1997
- This deviceK032038 Pyramis Ecg Management System Model Numbers, 92600 and 92601Quinton, Inc. · 2003
- Descendant · cites it directly · 13 of its ownK050858 Ascentia Heartstation Ecg Management SystemHeartlab, Inc. · 2005 · Recalled
- Descendant · cites it directly · 8 of its ownK061905 Horizon Cardiology Ecg-Mckesson's Ecg Management System, Model 1.0Medcon, Ltd. · 2006
- Descendant · 2 generations on · 7 of its ownK113515 Horizon Cardiology Ecg ManagementMckesson Israel, Ltd. · 2012 · Recalled
- Descendant · 3 generations on · 6 of its ownK133534 Mckesson Cardiology Ecg MobileMckesson Israel, Ltd. · 2014
- Descendant · 4 generations on · 4 of its ownK151774 CARESTREAM Vue MotionCarestream Health, Inc. · 2015 · Recalled
Showing 5 of 20 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 20 · See all- K050858Ascentia Heartstation Ecg Management SystemHeartlab, Inc. · 2005 · cites it directly13descendants
- K061905Horizon Cardiology Ecg-Mckesson's Ecg Management System, Model 1.0Medcon, Ltd. · 2006 · cites it directly8descendants
- K113515Horizon Cardiology Ecg ManagementMckesson Israel, Ltd. · 2012 · 2 generations on7descendants
- K133534Mckesson Cardiology Ecg MobileMckesson Israel, Ltd. · 2014 · 3 generations on6descendants
- K151774CARESTREAM Vue MotionCarestream Health, Inc. · 2015 · 4 generations on4descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −2 | K945626 | Quinton Model 710 Stress Electrocardiograph | Quinton, Inc. | 1995 | — |
| −1 | K964784 | Synergy Cardiology Information System (00431) | Quinton, Inc. | 1997 | — |
| 0 (this device) | K032038 | Pyramis Ecg Management System Model Numbers, 92600 and 92601 | Quinton, Inc. | 2003 | — |
| +1 | K050858 | Ascentia Heartstation Ecg Management System | Heartlab, Inc. | 2005 | 1 |
| +1 | K061905 | Horizon Cardiology Ecg-Mckesson's Ecg Management System, Model 1.0 | Medcon, Ltd. | 2006 | — |
| +2 | K113515 | Horizon Cardiology Ecg Management | Mckesson Israel, Ltd. | 2012 | 2 |
| +3 | K133534 | Mckesson Cardiology Ecg Mobile | Mckesson Israel, Ltd. | 2014 | — |
| +4 | K151774 | CARESTREAM Vue Motion | Carestream Health, Inc. | 2015 | 1 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2005 | 2 | 0 |
| 2006 | 1 | 0 |
| 2011 | 1 | 0 |
| 2012 | 2 | 0 |
| 2014 | 1 | 0 |
| 2015 | 3 | 0 |
| 2016 | 2 | 0 |
| 2017 | 1 | 0 |
| 2018 | 3 | 0 |
| 2020 | 1 | 0 |
| 2023 | 1 | 0 |
| 2024 | 1 | 0 |
| 2025 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in DQK? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new DQK device
- #1 K213682 HemoSphere Advanced Monitor, HemoSphere…score 26.6 · 28 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K964784 | Synergy Cardiology Information System (00431)Summary page 1…870.2340 Electrocardiograph (Accessory) 10. The Pyramis ECG Management System is substantially equivalent to the Quinton Synergy Cardiology Information System, CIS (K964784) 1 1. Description. The Pyramis system is a personal computer based, comprehensive data management tool, with multi-tas… | 1997 |
What descends from it? (20)
See all 204 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 8 years and passes through 1 company; a new generation was cleared every 6.1 years on median.
- None of the 2 ancestors has a recall.
- Of its descendants, K050858 (Heartlab, Inc., 2005) has gone furthest, with 13 descendants of its own.
- 1 other device also cites its predicate K964784.
How does its category compare?
All DQK devicesDQK Computer, Diagnostic, Programmable: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · DQK
23so far in 2026, the most since 2007
2026 to Oct 25, outlined.
Median 510(k) review, days · DQK
95in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · DQK
1in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · DQK
433in 2025
MAUDE reports naming product code DQK, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 13 | 83 | 4 | 18 |
| 2008 | 4 | 70 | 1 | 34 |
| 2009 | 12 | 93 | 2 | 40 |
| 2010 | 9 | 64 | 3 | 49 |
| 2011 | 12 | 69 | 2 | 55 |
| 2012 | 7 | 74 | 3 | 129 |
| 2013 | 13 | 68 | 1 | 180 |
| 2014 | 9 | 90 | 4 | 115 |
| 2015 | 7 | 125 | 2 | 131 |
| 2016 | 15 | 190 | 0 | 340 |
| 2017 | 7 | 146 | 2 | 252 |
| 2018 | 14 | 150 | 6 | 261 |
| 2019 | 15 | 113 | 1 | 218 |
| 2020 | 16 | 123 | 1 | 215 |
| 2021 | 16 | 132 | 1 | 351 |
| 2022 | 19 | 136 | 2 | 319 |
| 2023 | 21 | 133 | 2 | 340 |
| 2024 | 13 | 100 | 24 | 557 |
| 2025 | 22 | 95 | 1 | 433 |
| 2026 | 23 | 151 | 2 | — |
What is it indicated for?
The system may be used to store, retrieve, edit and report records of biologic origin such as ECG, exercise stress and Holter tests. The system can receive tests from a variety of devices. Data is then available through onscreen display, printer, email, fax, HIS (Hospital Information System) results reporting interface or via customized database queries. Users may view and edit interpretative statements and measurements through the onscreen display. The…
Read the full statement (148 words)
The system may be used to store, retrieve, edit and report records of biologic origin such as ECG, exercise stress and Holter tests.
The system can receive tests from a variety of devices. Data is then available through onscreen display, printer, email, fax, HIS (Hospital Information System) results reporting interface or via customized database queries.
Users may view and edit interpretative statements and measurements through the onscreen display.
The system can calculate multiple QTc metrics based upon acquired ECG data.
The system does not modify the original ECG waveform information, nor does it provide an automated ECG interpretive analysis of the data.
The system is designed to provide information for qualified clinicians responsible for the diagnosis and treatment of patients (adult and pediatric) with heart disease.
The system is designed for use in a clinical setting by physicians, nurses, clinical technicians, medical records personnel and medical record transcriptionists.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K032038 · printed Nov 6, 2026
Cite this page
510(k) Report. “K032038: Pyramis Ecg Management System Model Numbers, 92600 and 92601.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K032038
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026