510(k) Report

510(k) · Cleared

Recalled · Class II · 2023

Cardioserver

K052883510(k) TraditionalCleared Nov 1, 200519-day reviewClass II21 CFR 870.1425Recalls 1

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Datrix · DQK Computer, Diagnostic, Programmable

Cleared on Nov 1, 2005 as substantially equivalent to K032038 (Quinton, Inc., 2003) after a 19-day review. Its family tree reaches back 3 generations to 1995. 4 later devices descend from it. It has been recalled once.

Decided
Nov 1, 2005
Review
19 days
Class
Class II
Product code
DQK
Recalls
1
Predicates
1

Its longest line of descent runs back 3 generations to K945626 (1995). 4 later devices descend from it, 3 citing it directly.

Descendants, by year cleared 2018: 1 descendant cleared2011: 1 descendant cleared2012: 1 descendant cleared2015: 1 descendant clearedK945626 · Quinton Model 710 Stress Electrocardiograph · Quinton, Inc. · 1995K964784 · Synergy Cardiology Information System (00431) · Quinton, Inc. · 1997K032038 · Pyramis Ecg Management System Model Numbers, 92600 and 92601 · Quinton, Inc. · 20031995200020052010201520202025
  1. Root · 3 generations backK945626 Quinton Model 710 Stress ElectrocardiographQuinton, Inc. · 1995
  2. 2 generations backK964784 Synergy Cardiology Information System (00431)Quinton, Inc. · 1997
  3. 1 generation backK032038 Pyramis Ecg Management System Model Numbers, 92600 and 92601Quinton, Inc. · 2003
  4. This deviceK052883 CardioserverDatrix · 2005
  5. Descendant · cites it directly · 1 of its ownK103427 Mobileecg SystemMemtec Corp. · 2011
  6. Descendant · cites it directly · 0 of its ownK180432 AI-ECG PlatformShenzhen Carewell Electronics., Ltd. · 2018
  7. Descendant · 2 generations on · 0 of its ownK142349 TM eCloud ECG Analysis SystemTelemed Solutions, Inc. · 2015
  8. Descendant · cites it directly · 0 of its ownK123466 Healthview Ecg ManagerLumedx · 2012

Most influential descendants

Showing 4 of 4 · See all
  • K103427Mobileecg SystemMemtec Corp. · 2011 · cites it directly1descendant
  • K180432AI-ECG PlatformShenzhen Carewell Electronics., Ltd. · 2018 · cites it directly0descendants
  • K142349TM eCloud ECG Analysis SystemTelemed Solutions, Inc. · 2015 · 2 generations on0descendants
  • K123466Healthview Ecg ManagerLumedx · 2012 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K945626Quinton Model 710 Stress ElectrocardiographQuinton, Inc.1995—
−2K964784Synergy Cardiology Information System (00431)Quinton, Inc.1997—
−1K032038Pyramis Ecg Management System Model Numbers, 92600 and 92601Quinton, Inc.2003—
0 (this device)K052883CardioserverDatrix2005—
+1K103427Mobileecg SystemMemtec Corp.2011—
+1K180432AI-ECG PlatformShenzhen Carewell Electronics., Ltd.2018—
+2K142349TM eCloud ECG Analysis SystemTelemed Solutions, Inc.2015—
+1K123466Healthview Ecg ManagerLumedx2012—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201110
201210
201510
201810
FIG. 1 — Lineage of K052883, 1995–2018Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DQK? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DQK device

  1. #1 K213682 HemoSphere Advanced Monitor, HemoSphere…score 26.7 · 28 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K032038Pyramis Ecg Management System Model Numbers, 92600 and 92601
Summary page 1
…: The legally marketed device/s to which equivalence is being claimed is: Quinton Pyramis ECG Management System 3303 Monte Villa Parkway Bothell, WA 98021 K032038 Datrix CServer 510(k) Summary Appendix G 1iJ4…
Quinton, Inc.2003—

Also cleared against K032038: 3 other devices →

What descends from it? (4)

3 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K103427Mobileecg SystemMemtec Corp.20111
K180432AI-ECG PlatformShenzhen Carewell Electronics., Ltd.20180
K123466Healthview Ecg ManagerLumedx20120

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Aug 10, 2023Class IIZ-2647-2023Under Investigation by firmEpiphany, now a Baxter Healthcare company, is issuing an Urgent Medical Device Correction for the Cardio Server E3 ECG Management System software listed below due to a report of the caliper tool becoming non-responsive, preventing the…

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 10 years and passes through 2 companies; a new generation was cleared every 2.2 years on median.
  • None of the 3 ancestors has a recall.
  • Of its descendants, K103427 (Memtec Corp., 2011) has gone furthest, with 1 descendant of its own.
  • 3 other devices also cite its predicate K032038.

How does its category compare?

All DQK devices

DQK Computer, Diagnostic, Programmable: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · DQK

23so far in 2026, the most since 2007

2007: 132008: 42009: 122010: 92011: 122012: 72013: 132014: 92015: 72016: 152017: 72018: 142019: 152020: 162021: 162022: 192023: 212024: 132025: 222026 (partial year): 23
2007high 23 (2026) · low 4 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DQK

95in 2025

2007: 83 days median2008: 70 days median2009: 93 days median2010: 64 days median2011: 69 days median2012: 74 days median2013: 68 days median2014: 90 days median2015: 125 days median2016: 190 days median2017: 146 days median2018: 150 days median2019: 113 days median2020: 123 days median2021: 132 days median2022: 136 days median2023: 133 days median2024: 100 days median2025: 95 days median2026 (partial year): 151 days median
2007high 190 (2016) · low 64 (2010)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DQK

1in 2025

2007: 42008: 12009: 22010: 32011: 22012: 32013: 12014: 42015: 22017: 22018: 62019: 12020: 12021: 12022: 22023: 22024: 242025: 12026 (partial year): 2
2007high 24 (2024) · low 0 (2016)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · DQK

433in 2025

2007: 182008: 342009: 402010: 492011: 552012: 1292013: 1802014: 1152015: 1312016: 3402017: 2522018: 2612019: 2182020: 2152021: 3512022: 3192023: 3402024: 5572025: 433
2007high 557 (2024) · low 18 (2007)2025

MAUDE reports naming product code DQK, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071383418
2008470134
20091293240
2010964349
20111269255
20127743129
201313681180
20149904115
201571252131
2016151900340
201771462252
2018141506261
2019151131218
2020161231215
2021161321351
2022191362319
2023211332340
20241310024557
202522951433
2026231512—

What is it indicated for?

The CardioServer ECG Management System software is intended to be marketed to medical professionals and for point-of-care use. The software is designed to provide a database used through out the medical community to store, display, edit and print high resolution ECG data received from devices such as electrocardiographs. The CardioServer ECG Management System software allows medical professionals responsible for the diagnosis and treatment of patients…

Read the full statement (110 words)

The CardioServer ECG Management System software is intended to be marketed to medical professionals and for point-of-care use. The software is designed to provide a database used through out the medical community to store, display, edit and print high resolution ECG data received from devices such as electrocardiographs.

The CardioServer ECG Management System software allows medical professionals responsible for the diagnosis and treatment of patients (adult and pediatric) with heart disease to: review and edit specific patient ECG data including intervals such as QT measurements and algorithm generated preliminary interpretative statements. ECG records are all associated by patient ID and other demographic data. Secure access to the database is provided.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K052883: Cardioserver.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K052883

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026