Implex Corp. · EZX Mesh, Surgical, Metal

Cleared on Aug 21, 2003 as substantially equivalent to K023882 (Implex Corp., 2003) after a 28-day review. Its family tree reaches back 1 generation to 2003. 1 later device descends from it.

Decided
Aug 21, 2003
Review
28 days
Class
Class II
Product code
EZX
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to K023882 (2003). 1 later device descends from it, 1 citing it directly.

Descendants, by generation 1 generation forward: 1 descendant K023882 · The Hedrocel Trabecular Metal Reconstruction System · Implex Corp. · 20030
  1. Root · 1 generation backK023882 The Hedrocel Trabecular Metal Reconstruction SystemImplex Corp. · 2003
  2. This deviceK032282 Modification to Hedrocel Trabecular Metal Reconstruction SystemImplex Corp. · 2003
  3. Descendant · cites it directly · 0 of its ownK033384 The Hedrocel Trabecular Metal Reconstruction System, Model 06-165-ZZZZImplex Corp. · 2003

Most influential descendants

Showing 1 of 1 · See all
  • K033384The Hedrocel Trabecular Metal Reconstruction System, Model 06-165-ZZZZImplex Corp. · 2003 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K023882The Hedrocel Trabecular Metal Reconstruction SystemImplex Corp.2003—
0 (this device)K032282Modification to Hedrocel Trabecular Metal Reconstruction SystemImplex Corp.2003—
+1K033384The Hedrocel Trabecular Metal Reconstruction System, Model 06-165-ZZZZImplex Corp.2003—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200310
FIG. 1 — Lineage of K032282, 2003–2003Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in EZX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K023882The Hedrocel Trabecular Metal Reconstruction System
Summary page 2
…Reconstructive System was tested per Data: FDA guidance documents and applicable standards for KO10378, as referenced in the predicate 023882. In addition, mechanical test data found in MAF #920 indicate the Hedrocel porous tantalum possesses…
Implex Corp.2003—
†K010378Hedrocel Vertebral Body Replacement, Model XX-Yyy-ZZZZImplex Corp.2002—

Also cleared against K023882: 2 other devices →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K033384The Hedrocel Trabecular Metal Reconstruction System, Model 06-165-ZZZZImplex Corp.20030

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has no recall.
  • Of its descendants, K033384 (Implex Corp., 2003) has gone furthest, with 0 descendants of its own.
  • 2 other devices also cite its predicate K023882.

How does its category compare?

All EZX devices

EZX Mesh, Surgical, Metal: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · EZX

1in 2009

2009: 1
2007high 1 (2009) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · EZX

Too few EZX 510(k)s in any year since 2007 to give a median.

Recalls per year · EZX

1in 2015

2015: 1
2007high 1 (2015) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · EZX

1in 2025

2007: 42008: 82009: 52010: 82011: 62012: 112013: 82014: 72015: 92016: 42017: 72018: 112019: 292020: 252021: 352022: 42023: 52024: 52025: 1
2007high 35 (2021) · low 1 (2025)2025

MAUDE reports naming product code EZX, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—04
20080—08
20091—05
20100—08
20110—06
20120—011
20130—08
20140—07
20150—19
20160—04
20170—07
20180—011
20190—029
20200—025
20210—035
20220—04
20230—05
20240—05
20250—01
20260—0—

What is it indicated for?

The Hedrocel Trabecular Metal Reconstruction System is indicated for use in reinforcing weak and/or deficient bony tissues in orthopaedic surgical procedures such as pelvic reconstruction, acetabular reconstruction, cement restriction, and in long bone procedures such as femoral and humeral reconstruction. When used in long bone procedures, ancillary fixation, such as plates and screws, must be used. The Hedrocel Trabecular Metal Reconstruction System may also be used with bone graft.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K032282: Modification to Hedrocel Trabecular Metal Reconstruction System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K032282

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026