Lafaci

K032400510(k) TraditionalCleared May 7, 2004277-day reviewClass II21 CFR 878.5070

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Vision Pro, LLC · FYD Apparatus, Exhaust, Surgical

Cleared on May 7, 2004 as substantially equivalent to K924732 (Buffalo Filter Co., Inc., 1993) and 5 other predicates after a 277-day review. Its family tree reaches back 1 generation to 1985.

Decided
May 7, 2004
Review
277 days
Class
Class II
Product code
FYD
Recalls
None
Predicates
6

Its longest line of descent runs back 1 generation to K852649 (1985). 6 ancestors in all. No later device cites it as a predicate yet.

Other ancestors, by year cleared 1996: 1 other ancestor1994: 1 other ancestor1993: 2 other ancestors1991: 1 other ancestorK852649 · Pressure Regulator/Y Connector · C.R. Bard, Inc. · 198519851990199520002005
Other ancestors, by generation 1 generation back: 5 other ancestors K852649 · Pressure Regulator/Y Connector · C.R. Bard, Inc. · 19850
  1. Root · 1 generation backK852649 Pressure Regulator/Y ConnectorC.R. Bard, Inc. · 1985
  2. This deviceK032400 LafaciVision Pro, LLC · 2004
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K852649Pressure Regulator/Y ConnectorC.R. Bard, Inc.1985—
0 (this device)K032400LafaciVision Pro, LLC2004—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199110
199320
199410
199610
FIG. 1 — Lineage of K032400, 1985–2004Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in FYD? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new FYD device

  1. #1 K240127 PlumeSafe X5 Smoke Management Systemscore 8.7 · 4 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (14)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K924732Porta Plumesafe (TM) 601 Smoke Evacuation System
Summary page 2
…Page 1 of 1 Predicate Device(s) 510(k) Device Manufacturer Number K924732 or Dell PlumeSafe and Plume Aspiration fixation Buffalo Filter / Asico K924731 Ring Handpiece (PlumeSafe 601 or 1201)…
Buffalo Filter Co., Inc.1993—
*K924731Plumesafe (TM) 1201 Smoke Evacuation System
Summary page 2
…0(k) Device Manufacturer Number K924732 or Dell PlumeSafe and Plume Aspiration fixation Buffalo Filter / Asico K924731 Ring Handpiece (PlumeSafe 601 or 1201) Unknown Visx Star 3 Plume Evacuation Visx, Inc. K911808…
Buffalo Filter Co., Inc.1993—
*K911808Gemini Ophthalmic Surgery System
Summary page 2
…spiration fixation Buffalo Filter / Asico K924731 Ring Handpiece (PlumeSafe 601 or 1201) Unknown Visx Star 3 Plume Evacuation Visx, Inc. K911808 Accurus Surgical System Alcon Laboratories K935218 Schuco-Vac Model 178 Aspirator…
Alcon Laboratories19912
*K935218Schuco-Vac Model 178
Summary page 2
…afe 601 or 1201) Unknown Visx Star 3 Plume Evacuation Visx, Inc. K911808 Accurus Surgical System Alcon Laboratories K935218 Schuco-Vac Model 178 Aspirator Schuco, Inc. Exempt Slade LASIK Aspiration Lid Speculum ASI…
Schuco, Inc.1994—
*K963434Viscous Fluid System
Summary page 2
…uco, Inc. Exempt Slade LASIK Aspiration Lid Speculum ASICO Exempt Kritzinger-Udegraf LASIK Irrigation Cannula- ASICO 16 guage K963434 Continuous Fluid Air Exchange Escalon Trek Medical K852649 Regulator, pressure, gas cylinder…
Escalon Trek Medical1996—
*K852649Pressure Regulator/Y Connector
Summary page 2
…pt Kritzinger-Udegraf LASIK Irrigation Cannula- ASICO 16 guage K963434 Continuous Fluid Air Exchange Escalon Trek Medical K852649 Regulator, pressure, gas cylinder C.R.Bard Exempt Gimble-Chayet LASIK Drain Katina…
C.R. Bard, Inc.1985—
*—Visx Star 3 Plume Evacuation
Named without a submission number
—
*—Slade LASIK Aspiration Lid Speculum
Named without a submission number
—
*—Kritzinger-Udegraf LASIK Irrigation Cannula-16 guage
Named without a submission number
—
*—Gimble-Chayet LASIK Drain
Named without a submission number
—
*—Melki Lasik Flap Stabilizer
Named without a submission number
—
*—Maldonado LASIK Posterior Ablation Platform
Named without a submission number
—
*—Kraff Nasal Solid Blade Speculum
Named without a submission number
—
*—Whitten LASIK Fixation Ring
Named without a submission number
—

Also cleared against K924732: 3 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • 1 of the 6 ancestors has a recall of any class.
  • 3 other devices also cite its predicate K924732.

How does its category compare?

All FYD devices

FYD Apparatus, Exhaust, Surgical: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · FYD

2in 2024

2009: 12014: 12015: 12017: 12018: 12019: 32020: 12021: 12022: 12024: 2
2007high 3 (2019) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FYD

71in 2019

2019: 71 days median
2007high 71 (2019)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · FYD

3so far in 2026, the most since 2007

2010: 12026 (partial year): 3
2007high 3 (2026) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · FYD

15in 2025

2007: 32008: 42009: 52010: 392011: 1502012: 1202013: 1422014: 712015: 212016: 22017: 32018: 52019: 112020: 112021: 202022: 462023: 192024: 112025: 15
2007high 150 (2011) · low 2 (2016)2025

MAUDE reports naming product code FYD, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—03
20080—04
20091—05
20100—139
20110—0150
20120—0120
20130—0142
20141—071
20151—021
20160—02
20171—03
20181—05
2019371011
20201—011
20211—020
20221—046
20230—019
20242—011
20250—015
20260—3—

What is it indicated for?

The LaFaci Surgical System is intended for use during LASIK procedures. The LaFaci Surgical System consists of a reusable Handpiece, Surgical Cart, and disposable Tubing Accessories. The LaFaci System provides ocular fixation and containment of surgical field, comeal flap placement and flap re-positioning, and is used for ophthalmic plume aspiration, irrigation, fluid aspiration, and the delivery of micro filtered air to the surgical field.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K032400: Lafaci.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K032400

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026