Fukuda Denshi Model FF Sonic UF-750XT

K033209510(k) TraditionalCleared Oct 31, 200328-day reviewClass II21 CFR 892.1550

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Fukuda Denshi USA, Inc. · IYN System, Imaging, Pulsed Doppler, Ultrasonic

Cleared on Oct 31, 2003 as substantially equivalent to K990401 (Fukuda Denshi USA, Inc., 1999) after a 28-day review. Its family tree reaches back 3 generations to 1993. 2 later devices descend from it.

Decided
Oct 31, 2003
Review
28 days
Class
Class II
Product code
IYN
Recalls
None
Predicates
1

Its longest line of descent runs back 3 generations to K922208 (1993). 4 ancestors in all. 2 later devices descend from it, 2 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 1994: 1 other ancestor2008: 1 descendant cleared2005: 1 descendant clearedK922208 · Fukuda Denshi Model UF-4500 · Fukuda Denshi USA, Inc. · 1993K955543 · Ultrasound System Model UF-3500 · Fukuda Denshi USA, Inc. · 1997K990401 · Fukuda Denshi FF Sonic UF-5800 General Purpose Ultrasound Scanning System with Doppler · Fukuda Denshi USA, Inc. · 19991990200020102020
  1. Root · 3 generations backK922208 Fukuda Denshi Model UF-4500Fukuda Denshi USA, Inc. · 1993
  2. 2 generations backK955543 Ultrasound System Model UF-3500Fukuda Denshi USA, Inc. · 1997
  3. 1 generation backK990401 Fukuda Denshi FF Sonic UF-5800 General Purpose Ultrasound Scanning…Fukuda Denshi USA, Inc. · 1999
  4. This deviceK033209 Fukuda Denshi Model FF Sonic UF-750XTFukuda Denshi USA, Inc. · 2003
  5. Descendant · cites it directly · 0 of its ownK082656 Model FF Sonic US-750 XT Diagnostic Ultrasound System 3D Imaging UnitFukuda Denshi USA, Inc. · 2008
  6. Descendant · cites it directly · 0 of its ownK050363 Fukuda Denshi Model UF-850XTDFukuda Denshi USA, Inc. · 2005

Most influential descendants

Showing 2 of 2 · See all
  • K082656Model FF Sonic US-750 XT Diagnostic Ultrasound System 3D Imaging UnitFukuda Denshi USA, Inc. · 2008 · cites it directly0descendants
  • K050363Fukuda Denshi Model UF-850XTDFukuda Denshi USA, Inc. · 2005 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K922208Fukuda Denshi Model UF-4500Fukuda Denshi USA, Inc.1993—
−2K955543Ultrasound System Model UF-3500Fukuda Denshi USA, Inc.1997—
−1K990401Fukuda Denshi FF Sonic UF-5800 General Purpose Ultrasound Scanning System with…Fukuda Denshi USA, Inc.1999—
0 (this device)K033209Fukuda Denshi Model FF Sonic UF-750XTFukuda Denshi USA, Inc.2003—
+1K082656Model FF Sonic US-750 XT Diagnostic Ultrasound System 3D Imaging UnitFukuda Denshi USA, Inc.2008—
+1K050363Fukuda Denshi Model UF-850XTDFukuda Denshi USA, Inc.2005—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199410

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200510
200810
FIG. 1 — Lineage of K033209, 1993–2008Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in IYN? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new IYN device

  1. #1 K240850 EPIQ Series Diagnostic Ultrasound Systems…score 32.1 · 24 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K990401Fukuda Denshi FF Sonic UF-5800 General Purpose Ultrasound Scanning System with Doppler
Summary page 1
…Marketed Device: Fukuda Denshi model FF sonic UF-5800 General Purpose Ultrasound Scanner with Doppler, 5 10(k) No. K990401 currently in commercial distribution. Device Description: The Fukuda Denshi model FF soni…
Fukuda Denshi USA, Inc.1999—

What descends from it? (2)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K082656Model FF Sonic US-750 XT Diagnostic Ultrasound System 3D Imaging UnitFukuda Denshi USA, Inc.20080
K050363Fukuda Denshi Model UF-850XTDFukuda Denshi USA, Inc.20050

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 10 years and passes through 1 company; a new generation was cleared every 3.5 years on median.
  • None of the 4 ancestors has a recall.
  • Of its descendants, K082656 (Fukuda Denshi USA, Inc., 2008) has gone furthest, with 0 descendants of its own.

How does its category compare?

All IYN devices

IYN System, Imaging, Pulsed Doppler, Ultrasonic: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · IYN

57in 2025

2007: 132008: 252009: 182010: 292011: 392012: 432013: 512014: 562015: 542016: 602017: 642018: 592019: 472020: 572021: 462022: 532023: 442024: 502025: 572026 (partial year): 44
2007high 64 (2017) · low 13 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · IYN

124in 2025

2007: 26 days median2008: 18 days median2009: 29 days median2010: 67 days median2011: 46 days median2012: 37 days median2013: 60 days median2014: 39 days median2015: 55 days median2016: 56 days median2017: 83 days median2018: 85 days median2019: 79 days median2020: 72 days median2021: 105 days median2022: 105 days median2023: 115 days median2024: 119 days median2025: 124 days median2026 (partial year): 107 days median
2007high 124 (2025) · low 18 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · IYN

10in 2025

2007: 162008: 122009: 82010: 102011: 82012: 32013: 82014: 22015: 32016: 22018: 72020: 42021: 82022: 102023: 42024: 12025: 102026 (partial year): 2, 1 Class I
2007high 16 (2007) · low 0 (2017)2026

Class I (1 since 2007) Class II/III not classified

Adverse event reports per year · IYN

610in 2025

2007: 32008: 22009: 92010: 172011: 182012: 202013: 182014: 482015: 1162016: 1452017: 1462018: 852019: 592020: 672021: 2132022: 1862023: 2292024: 2662025: 610
2007high 610 (2025) · low 2 (2008)2025

MAUDE reports naming product code IYN, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071326163
20082518122
2009182989
201029671017
20113946818
20124337320
20135160818
20145639248
201554553116
201660562145
201764830146
20185985785
20194779059
20205772467
2021461058213
20225310510186
2023441154229
2024501191266
20255712410610
2026441072 (1)—

What is it indicated for?

The device is intended to be used for applications in fetal, abdominal, pediatric, small organ (defined as the thyroid, breast and testes), cardiac (adult and pediatric), transvaginal, peripheral vessel and musculo-skeletal (Conventional and Superficial). The UF-75OXT incorporates built-in measurement and calculation packages that are to be used by competent health care professionals. The FF sonic UF-75OXT is a prescription device intended to be use by…

Read the full statement (118 words)

The device is intended to be used for applications in fetal, abdominal, pediatric, small organ (defined as the thyroid, breast and testes), cardiac (adult and pediatric), transvaginal, peripheral vessel and musculo-skeletal (Conventional and Superficial). The UF-75OXT incorporates built-in measurement and calculation packages that are to be used by competent health care professionals. The FF sonic UF-75OXT is a prescription device intended to be use by or on the order of a physician or similarly qualified healthcare professional. The device is intended to be used on any patient; neonate, pediatric, or adult; where the placement and positioning of the transducer does not interfere with or complicate the treatment of the patient. This device is not intended for home use.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K033209: Fukuda Denshi Model FF Sonic UF-750XT.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K033209

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026