RT 138 & RT 141 Dual-Heated Neonatal Breathing Circuits

K034026510(k) TraditionalCleared Jan 12, 2005380-day reviewClass II21 CFR 868.5270

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Fisher & Paykel Healthcare, Ltd. · BZE Heater, Breathing System W/Wo Controller (Not Humidifier Or Nebulizer

Cleared on Jan 12, 2005 as substantially equivalent to K020332 (Fisher & Paykel Healthcare, Ltd., 2003) after a 380-day review. Its family tree reaches back 4 generations to 1992. 1 of the 21 devices in its family, counting itself, has a Class I recall. 12 later devices descend from it.

Decided
Jan 12, 2005
Review
380 days
Class
Class II
Product code
BZE
Recalls
None
Predicates
1

Its longest line of descent runs back 4 generations to K913368 (1992). 8 ancestors in all, the oldest K902506 (1991). 12 later devices descend from it, 2 citing it directly. 1 of the 21 devices in this family, counting this one, has a Class I recall.

Other ancestors, by year clearedDescendants, by year cleared 2000: 1 other ancestor1994: 1 other ancestor1991: 1 other ancestor1992: 1 other ancestor2012: 2 descendants cleared2016: 2 descendants cleared2023: 2 descendants cleared2018: 1 descendant cleared, 1 with a Class I recall12026: 1 descendant cleared2015: 1 descendant cleared2017: 1 descendant cleared2024: 1 descendant cleared2025: 1 descendant clearedK913368 · Models MR700/MR720/MR730 Dual Servo Resp Humid Acc · Fisher & Paykel Electronics, Ltd. · 1992K953392 · HC500 Servo-Controlled Heated Respiratory Humidifier (& Accessories) · Fisher & Paykel Electronics, Ltd. · 1996K983112 · Respiratory Humidifier, Model # MR850 · Fisher & Paykel Healthcare, Ltd. · 1998 · recalledK020332 · Respiratory Humidifier, Model MR850 · Fisher & Paykel Healthcare, Ltd. · 2003 · recalled1990200020102020
Other ancestors, by generationDescendants, by generation 2 generations back: 1 other ancestor3 generations back: 2 other ancestors4 generations back: 1 other ancestor 1 generation forward: 2 descendants2 generations forward: 6 descendants, 1 with a Class I recall13 generations forward: 4 descendants K020332 · Respiratory Humidifier, Model MR850 · Fisher & Paykel Healthcare, Ltd. · 2003 · recalledK983112 · Respiratory Humidifier, Model # MR850 · Fisher & Paykel Healthcare, Ltd. · 1998 · recalledK953392 · HC500 Servo-Controlled Heated Respiratory Humidifier (& Accessories) · Fisher & Paykel Electronics, Ltd. · 1996K913368 · Models MR700/MR720/MR730 Dual Servo Resp Humid Acc · Fisher & Paykel Electronics, Ltd. · 19920
  1. Root · 4 generations backK913368 Models MR700/MR720/MR730 Dual Servo Resp Humid AccFisher & Paykel Electronics, Ltd. · 1992
  2. 3 generations backK953392 HC500 Servo-Controlled Heated Respiratory Humidifier (& Accessories)Fisher & Paykel Electronics, Ltd. · 1996
  3. 2 generations backK983112 Respiratory Humidifier, Model # MR850Fisher & Paykel Healthcare, Ltd. · 1998 · Recalled
  4. 1 generation backK020332 Respiratory Humidifier, Model MR850Fisher & Paykel Healthcare, Ltd. · 2003 · Recalled
  5. This deviceK034026 RT 138 & RT 141 Dual-Heated Neonatal Breathing CircuitsFisher & Paykel Healthcare, Ltd. · 2005
  6. Descendant · cites it directly · 10 of its ownK103767 Dual Heated Infant Vreathing CirouitsFisher & Paykel Healthcare, Ltd. · 2012
  7. Descendant · 2 generations on · 6 of its ownK122432 Adult Evaqua 2' Dual Heated Breathing CircuitsFisher & Paykel Healthcare, Ltd. · 2012
  8. Descendant · 2 generations on · 1 of its ownK220703 F&P 950 Respiratory HumidifierFisher & Paykel Healthcare · 2023
  9. Descendant · 2 generations on · 1 of its ownK222822 VentStar Helix dual heated (N) Plus (MP02650), VentStar Helix heated…Draegerwerk AG & CO Kgaa · 2023
  10. Descendant · 2 generations on · 1 of its ownK152029 Hamilton-H900, Hamilton-BC8022, Hamilton-BC4022, Hamilton-BC8010…Hamilton Medical AG · 2016

Showing 5 of 12 descendants. See all descendants

Descendants cleared per year

2012: 22015: 12016: 22017: 12018: 12023: 22024: 12025: 12026: 1
2012high 2 (2012) · low 0 (2013)2026

Class I recalls in this family

Most influential descendants

Showing 5 of 12 · See all
  • K103767Dual Heated Infant Vreathing CirouitsFisher & Paykel Healthcare, Ltd. · 2012 · cites it directly10descendants
  • K122432Adult Evaqua 2' Dual Heated Breathing CircuitsFisher & Paykel Healthcare, Ltd. · 2012 · 2 generations on6descendants
  • K220703F&P 950 Respiratory HumidifierFisher & Paykel Healthcare · 2023 · 2 generations on1descendant
  • K222822VentStar Helix dual heated (N) Plus (MP02650), VentStar Helix heated (N) Plus (MP02608)Draegerwerk AG & CO Kgaa · 2023 · 2 generations on1descendant
  • K152029Hamilton-H900, Hamilton-BC8022, Hamilton-BC4022, Hamilton-BC8010, Hamilton-BC4010Hamilton Medical AG · 2016 · 2 generations on1descendant
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K913368Models MR700/MR720/MR730 Dual Servo Resp Humid AccFisher & Paykel Electronics, Ltd.1992—
−3K953392HC500 Servo-Controlled Heated Respiratory Humidifier (& Accessories)Fisher & Paykel Electronics, Ltd.1996—
−2K983112Respiratory Humidifier, Model # MR850Fisher & Paykel Healthcare, Ltd.19985
−1K020332Respiratory Humidifier, Model MR850Fisher & Paykel Healthcare, Ltd.20031
0 (this device)K034026RT 138 & RT 141 Dual-Heated Neonatal Breathing CircuitsFisher & Paykel Healthcare, Ltd.2005—
+1K103767Dual Heated Infant Vreathing CirouitsFisher & Paykel Healthcare, Ltd.2012—
+2K122432Adult Evaqua 2' Dual Heated Breathing CircuitsFisher & Paykel Healthcare, Ltd.2012—
+2K220703F&P 950 Respiratory HumidifierFisher & Paykel Healthcare2023—
+2K222822VentStar Helix dual heated (N) Plus (MP02650), VentStar Helix heated (N) Plus…Draegerwerk AG & CO Kgaa2023—
+2K152029Hamilton-H900, Hamilton-BC8022, Hamilton-BC4022, Hamilton-BC8010…Hamilton Medical AG2016—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199110
199210
199410
200010

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201220
201510
201620
201710
201811
202320
202410
202510
202610
FIG. 1 — Lineage of K034026, 1992–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new BZE device

  1. #1 K252066 inspired™ Heated Breathing Circuit (510-008)…score 13.3 · 7 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K020332Respiratory Humidifier, Model MR850
Summary page 1
…atal Breathing Circuit RT141 Dual Heated Neonatal Breathing Circuit Heated Breathing Circuit Breathing System Heater (21 CFR 868.5270) RT130 Neonatal Breathing Circuit K020332 RT131 Neonatal Breathing Circuit K020332 2y Fisher & Paykel Healthcare 510k Notification Dual-heated Neonatal Br…
Fisher & Paykel Healthcare, Ltd.20031

Also cleared against K020332: 4 other devices →

What descends from it? (12)

See all 12

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K103767Dual Heated Infant Vreathing CirouitsFisher & Paykel Healthcare, Ltd.201210
K160540Flexicare Neonatal Heated Wire Breathing SystemFlexicare Medical Limited.20160

Has anything in its family been recalled? (1 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K173280Neonatal ConchaSmart Breathing CircuitsTeleflexmedical, Inc. · 2018 · 2 generations on · ◆ in the 2018 descendants bar of FIG. 11 Class I recall

What does this lineage say?

  • The line of descent spans 13 years and passes through 2 companies; a new generation was cleared every 4.2 years on median.
  • 2 of the 8 ancestors have a recall of any class.
  • Of its descendants, K103767 (Fisher & Paykel Healthcare, Ltd., 2012) has gone furthest, with 10 descendants of its own.
  • 4 other devices also cite its predicate K020332.

How does its category compare?

All BZE devices

BZE Heater, Breathing System W/Wo Controller (Not Humidifier Or Nebulizer: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · BZE

1in 2025

2010: 22011: 12012: 22014: 12015: 12016: 52017: 12018: 12021: 12023: 12024: 22025: 12026 (partial year): 2
2007high 5 (2016) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · BZE

241in 2016

2016: 241 days median
2007high 241 (2016)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · BZE

No recall names BZE since 2007.

Adverse event reports per year · BZE

193in 2025

2007: 692008: 742009: 802010: 1262011: 1922012: 3342013: 3872014: 3382015: 1552016: 2142017: 2092018: 1032019: 1342020: 1232021: 1242022: 1522023: 1252024: 1722025: 193
2007high 387 (2013) · low 69 (2007)2025

MAUDE reports naming product code BZE, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—069
20080—074
20090—080
20102—0126
20111—0192
20122—0334
20130—0387
20141—0338
20151—0155
201652410214
20171—0209
20181—0103
20190—0134
20200—0123
20211—0124
20220—0152
20231—0125
20242—0172
20251—0193
20262—0—

What is it indicated for?

The dual-heated breathing circuits are intended as conduits of breathing gas for

ventilation of patients, and to maintain the temperature of humidified inspired gas.

The RT236 is used for flow rates between 0.3 and 4 L/min, and the RT235 is for flow

rates greater than 4 L/min, for infant patients.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K034026: RT 138 & RT 141 Dual-Heated Neonatal Breathing Circuits.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K034026

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026