510(k) Report

510(k) · Cleared

Cleared

Cyto-Chex BCT

K040107510(k) TraditionalCleared Jul 27, 2004189-day reviewClass II21 CFR 862.1675

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Streck Laboratories, Inc. · JKA Tubes, Vials, Systems, Serum Separators, Blood Collection

Cleared on Jul 27, 2004 as substantially equivalent to K030596 (Immunicon Corp., 2003) after a 189-day review. Its family tree reaches back 1 generation to 2003. 2 later devices descend from it.

Decided
Jul 27, 2004
Review
189 days
Class
Class II
Product code
JKA
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to K030596 (2003). 2 later devices descend from it, 1 citing it directly.

Descendants, by year cleared 2008: 1 descendant cleared2017: 1 descendant clearedK030596 · Immunicon Cellsave Preservative Tube · Immunicon Corp. · 2003200020052010201520202025
Descendants, by generation 1 generation forward: 1 descendant2 generations forward: 1 descendant K030596 · Immunicon Cellsave Preservative Tube · Immunicon Corp. · 20030
  1. Root · 1 generation backK030596 Immunicon Cellsave Preservative TubeImmunicon Corp. · 2003
  2. This deviceK040107 Cyto-Chex BCTStreck Laboratories, Inc. · 2004
  3. Descendant · cites it directly · 1 of its ownK080552 Cyto-Chex BCTStreck · 2008 · Recalled
  4. Descendant · 2 generations on · 0 of its ownK162723 TransFix/EDTA Vacuum Blood Collection TubesCaltag Medsystems, Ltd. · 2017

Most influential descendants

Showing 2 of 2 · See all
  • K080552Cyto-Chex BCTStreck · 2008 · cites it directly1descendant
  • K162723TransFix/EDTA Vacuum Blood Collection TubesCaltag Medsystems, Ltd. · 2017 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K030596Immunicon Cellsave Preservative TubeImmunicon Corp.2003—
0 (this device)K040107Cyto-Chex BCTStreck Laboratories, Inc.2004—
+1K080552Cyto-Chex BCTStreck20081
+2K162723TransFix/EDTA Vacuum Blood Collection TubesCaltag Medsystems, Ltd.2017—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200810
201710
FIG. 1 — Lineage of K040107, 2003–2017Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in JKA? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new JKA device

  1. #1 K200027 Blood Collection Needle with/without Holder…score 15.6 · 3 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K030596Immunicon Cellsave Preservative Tube
Summary page 1
…me: Blood specimen collection device Classification Name: Blood specimen collection device, 210CFR862.1675 Predicate Device: Immunicon CellSaveTM, K030596 Description: Cyto-Chex BOT consists of a standard 13 x 75mm glass blood collection tube containing 57u1 of s…
Immunicon Corp.2003—

What descends from it? (2)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K080552Cyto-Chex BCTStreck20081

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has no recall.
  • Of its descendants, K080552 (Streck, 2008) has gone furthest, with 1 descendant of its own.

How does its category compare?

All JKA devices

JKA Tubes, Vials, Systems, Serum Separators, Blood Collection: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · JKA

7in 2025

2007: 42008: 22009: 22010: 42012: 12013: 32014: 12015: 12016: 42017: 22018: 12019: 62020: 62021: 42022: 92023: 172024: 62025: 72026 (partial year): 8
2007high 17 (2023) · low 0 (2011)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · JKA

115in 2025

2007: 281 days median2010: 28 days median2013: 244 days median2016: 116 days median2019: 181 days median2020: 181 days median2021: 217 days median2022: 164 days median2023: 189 days median2024: 240 days median2025: 115 days median2026 (partial year): 250 days median
2007high 281 (2007) · low 28 (2010)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · JKA

13in 2025

2007: 32008: 32009: 32010: 42011: 142012: 22013: 12014: 12015: 62016: 12017: 22018: 22019: 92021: 32022: 22023: 22025: 132026 (partial year): 1
2007high 14 (2011) · low 0 (2020)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · JKA

6,089in 2025

2007: 732008: 782009: 422010: 372011: 672012: 542013: 332014: 682015: 412016: 652017: 2,0392018: 9,7312019: 6,4692020: 3,7742021: 3,6102022: 3,3752023: 4,4002024: 4,6092025: 6,089
2007high 9,731 (2018) · low 33 (2013)2025

MAUDE reports naming product code JKA, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20074281373
20082—378
20092—342
2010428437
20110—1467
20121—254
20133244133
20141—168
20151—641
20164116165
20172—22,039
20181—29,731
2019618196,469
2020618103,774
2021421733,610
2022916423,375
20231718924,400
2024624004,609
20257115136,089
202682501—

What is it indicated for?

Cyto-Chex® BCT is intended for the collection and storage of blood specimens for immunophenotyping of WBC by flow-cytometry. Recovery of lymphocyte subset cell markers of the HIV panel can be accomplished over a 7 day period following collection.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K040107: Cyto-Chex BCT.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K040107

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026