510(k) Report

510(k) · Cleared

Cleared

TransFix/EDTA Vacuum Blood Collection Tubes

K162723510(k) TraditionalCleared Jun 22, 2017266-day reviewClass II21 CFR 862.1675

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Caltag Medsystems, Ltd. · GIM Tubes, Vacuum Sample, With Anticoagulant

Cleared on Jun 22, 2017 as substantially equivalent to K080552 (Streck, 2008) after a 266-day review. Its family tree reaches back 3 generations to 2003.

Decided
Jun 22, 2017
Review
266 days
Class
Class II
Product code
GIM
Recalls
None
Predicates
1

Its longest line of descent runs back 3 generations to K030596 (2003). No later device cites it as a predicate yet.

  1. Root · 3 generations backK030596 Immunicon Cellsave Preservative TubeImmunicon Corp. · 2003
  2. 2 generations backK040107 Cyto-Chex BCTStreck Laboratories, Inc. · 2004
  3. 1 generation backK080552 Cyto-Chex BCTStreck · 2008 · Recalled
  4. This deviceK162723 TransFix/EDTA Vacuum Blood Collection TubesCaltag Medsystems, Ltd. · 2017
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K030596Immunicon Cellsave Preservative TubeImmunicon Corp.2003—
−2K040107Cyto-Chex BCTStreck Laboratories, Inc.2004—
−1K080552Cyto-Chex BCTStreck20081
0 (this device)K162723TransFix/EDTA Vacuum Blood Collection TubesCaltag Medsystems, Ltd.2017—
FIG. 1 — Lineage of K162723, 2003–2017Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in GIM? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GIM device

  1. #1 K240455 BD Vacutainer® Citrate Blood Collection Tubesscore 8.3 · 1 generation · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K080552Cyto-Chex BCT
Summary page 4
…tion of the legally marketed predicate devices Cyto-Chex® BCT (Blood Collection Tubes, Streck Laboratories, Inc., Omaha, NE), cleared under K080552 807.92 (a)(4): Device Description TransFix®/EDTA Vacuum Blood Collection Tubes (TVTs) are intended for collection and storage of…
Streck20081

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 14 years and passes through 4 companies; a new generation was cleared every 4.0 years on median.
  • 1 of the 3 ancestors has a recall of any class.

How does its category compare?

All GIM devices

GIM Tubes, Vacuum Sample, With Anticoagulant: FDA decisions, review times, recalls and adverse event reports over 20 years. 2017, this device’s year, is highlighted.

FDA decisions per year · GIM

1in 2024

2008: 12017: 12023: 22024: 1
2007high 2 (2023) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GIM

Too few GIM 510(k)s in any year since 2007 to give a median.

Recalls per year · GIM

1in 2025

2012: 12025: 1
2007high 1 (2012) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · GIM

641in 2025

2009: 12010: 12011: 12012: 32016: 22017: 122018: 2762019: 1452020: 1472021: 552022: 422023: 332024: 3162025: 641
2007high 641 (2025) · low 0 (2007)2025

MAUDE reports naming product code GIM, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20081—00
20090—01
20100—01
20110—01
20120—13
20130—00
20140—00
20150—00
20160—02
20171—012
20180—0276
20190—0145
20200—0147
20210—055
20220—042
20232—033
20241—0316
20250—1641
20260—0—

What is it indicated for?

TransFix/EDTA Vacuum Blood Collection Tubes (TVTs) are intended for collection and storage of human whole blood

specimens for immunophenotyping of white blood cells by flow cytometry. Recovery of lymphocyte subset markers of

the HIV panel can be accomplished over a 14-day period following collection.

TVTs are in-vitro diagnostic medical devices.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K162723: TransFix/EDTA Vacuum Blood Collection Tubes.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K162723

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026