510(k) · Cleared
ClearedSalter Labs Cpap High Flow Cannula System
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Salter Labs · BZD Ventilator, Non-Continuous (Respirator)
Cleared on Mar 4, 2005 as substantially equivalent to K010263 (Respironics, Inc., 2001) and 1 other predicate after a 400-day review. Its family tree reaches back 2 generations to 1996.
- Decided
- Mar 4, 2005
- Review
- 400 days
- Class
- Class II
- Product code
- BZD
- Recalls
- None
- Predicates
- 2
Its longest line of descent runs back 2 generations to K953930 (1996). 3 ancestors in all. No later device cites it as a predicate yet.
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −2 | K953930 | Virtuoso Smart Cpap System | Respironics, Inc. | 1996 | — |
| −1 | K993433 | Virtuoso LX Smart Cpap System | Respironics, Inc. | 1999 | — |
| 0 (this device) | K040202 | Salter Labs Cpap High Flow Cannula System | Salter Labs | 2005 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2001 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in BZD? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new BZD device
- #1 K250624 myAirscore 15.7 · 12 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (3)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K010263 | Remstar Plus Cpap System Our reading of the summary gave K012263, FDA’s number for Marquette Eagle Monitor Model 4000, Model N3024 (National Custom Ent., Inc.). Corrected to the number one digit away whose FDA name carries the summary’s words for the device, “Respironics REMstar CPAP System”. | 2001 |
| * | K993433 | Virtuoso LX Smart Cpap SystemSummary page 1…unknown) Respironics REMstar CPAP System (K012263) Respironics Virtuoso LX Smart CPAP System (K993433) Reason for Submission Initial Introduction into Interstate Commerce Substantial Equivalence The Salter L… | 1999 |
| * | — | InnoMed NasalAire™ CPAP Cannula Named without a submission number |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 9 years and passes through 2 companies; a new generation was cleared every 5.4 years on median.
- 1 of the 3 ancestors has a recall of any class.
- 7 other devices also cite its predicate K010263.
How does its category compare?
All BZD devicesBZD Ventilator, Non-Continuous (Respirator): FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · BZD
7in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · BZD
189in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · BZD
8in 2023
Class I (13 since 2007) Class II/III not classified
Adverse event reports per year · BZD
60,279in 2025
MAUDE reports naming product code BZD, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 21 | 83 | 29 | 65 |
| 2008 | 17 | 108 | 2 | 67 |
| 2009 | 23 | 90 | 1 | 147 |
| 2010 | 12 | 122 | 0 | 143 |
| 2011 | 23 | 125 | 1 | 189 |
| 2012 | 21 | 133 | 0 | 139 |
| 2013 | 23 | 127 | 0 | 82 |
| 2014 | 14 | 172 | 0 | 86 |
| 2015 | 11 | 224 | 0 | 114 |
| 2016 | 12 | 217 | 0 | 118 |
| 2017 | 5 | 221 | 0 | 148 |
| 2018 | 5 | 280 | 0 | 101 |
| 2019 | 6 | 231 | 4 (4) | 188 |
| 2020 | 6 | 137 | 0 | 126 |
| 2021 | 6 | 192 | 0 | 6,066 |
| 2022 | 4 | 253 | 0 | 90,768 |
| 2023 | 5 | 204 | 8 (7) | 27,987 |
| 2024 | 10 | 132 | 0 | 68,262 |
| 2025 | 7 | 189 | 0 | 60,279 |
| 2026 | 10 | 214 | 2 (2) | — |
What is it indicated for?
The Salter Labs High Volume CPAP Cannula System is intended for use in treating obstructive sleep apnea (OSA) in spontaneously breathing adult patients within a homecare and hospital environment.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K040202 · printed Nov 3, 2026
Cite this page
510(k) Report. “K040202: Salter Labs Cpap High Flow Cannula System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 3, 2026. https://510kreport.com/device/K040202
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026