510(k) · Cleared
ClearedMetal/Metal Hip System
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Encore Medical L.P. · KWA Prosthesis, Hip, Semi-Constrained (Metal Uncemented Acetabular Component)
Cleared on Nov 4, 2004 as substantially equivalent to K003250 (Encore Orthopedics, Inc., 2001) after a 266-day review. Its family tree reaches back 1 generation to 2001.
- Decided
- Nov 4, 2004
- Review
- 266 days
- Class
- Class III
- Product code
- KWA
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 1 generation to K003250 (2001). No later device cites it as a predicate yet.
- Root · 1 generation backK003250 FMP Metal/Metal Acetabular InsertEncore Orthopedics, Inc. · 2001
- This deviceK040354 Metal/Metal Hip SystemEncore Medical L.P. · 2004
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −1 | K003250 | FMP Metal/Metal Acetabular Insert | Encore Orthopedics, Inc. | 2001 | — |
| 0 (this device) | K040354 | Metal/Metal Hip System | Encore Medical L.P. | 2004 | — |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in KWA? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
- Candidate predicates for a device like this, rankedin the report
- Recall history across each candidate’s familyin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K003250 | FMP Metal/Metal Acetabular InsertSummary page 1…34-2 and the metal components are manufactured from materials conforming to ASTM F799. The design features of these parts are identical to those previously cleared under K003250.The metal shells are available with outside diameters of 48mm to 66mm (in 2mm increments). The shells accept a polyethylene liner… | 2001 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Its one ancestor has no recall.
How does its category compare?
All KWA devicesKWA Prosthesis, Hip, Semi-Constrained (Metal Uncemented Acetabular Component): FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · KWA
4in 2012
2026 to Oct 25, outlined.
Median 510(k) review, days · KWA
76in 2012
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · KWA
19in 2023
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · KWA
1,216in 2025
MAUDE reports naming product code KWA, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 8 | 74 | 0 | 213 |
| 2008 | 9 | 57 | 13 | 762 |
| 2009 | 7 | 139 | 0 | 820 |
| 2010 | 6 | 167 | 84 | 3,348 |
| 2011 | 11 | 101 | 28 | 17,737 |
| 2012 | 4 | 76 | 21 | 24,601 |
| 2013 | 0 | — | 1 | 20,020 |
| 2014 | 0 | — | 0 | 16,494 |
| 2015 | 0 | — | 0 | 12,339 |
| 2016 | 0 | — | 1 | 7,872 |
| 2017 | 0 | — | 1 | 6,847 |
| 2018 | 0 | — | 1 | 6,388 |
| 2019 | 0 | — | 2 | 7,628 |
| 2020 | 0 | — | 1 | 4,538 |
| 2021 | 0 | — | 0 | 2,064 |
| 2022 | 0 | — | 0 | 1,617 |
| 2023 | 0 | — | 19 | 1,474 |
| 2024 | 0 | — | 0 | 1,168 |
| 2025 | 0 | — | 0 | 1,216 |
| 2026 | 0 | — | 0 | — |
What is it indicated for?
Indications for use in total hip replacement include: degenerative joint disease including osteoarthritis and avascular necrosis; rheumatoid arthritis; correction of functional deformity; revision procedures where other treatments or devices have failed; and treatment of nonunion, femoral neck and trochanteric fractures of the proximal femur with head involvement, which is unmanageable using other techniques.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K040354 · printed Nov 6, 2026
Cite this page
510(k) Report. “K040354: Metal/Metal Hip System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K040354
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026