Exactrac 4.0 and Exactrac X-Ray 6D

K040585510(k) TraditionalCleared May 11, 200467-day reviewClass II21 CFR 892.5050

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Brainlab AG · IYE Accelerator, Linear, Medical

Cleared on May 11, 2004 as substantially equivalent to K003285 (Brainlab AG, 2001) after a 67-day review. Its family tree reaches back 1 generation to 2001. 41 later devices descend from it.

Decided
May 11, 2004
Review
67 days
Class
Class II
Product code
IYE
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to K003285 (2001). 41 later devices descend from it, 5 citing it directly.

Descendants, by year cleared 2007: 2 descendants cleared2006: 3 descendants cleared2014: 3 descendants cleared2008: 2 descendants cleared2010: 1 descendant cleared2012: 5 descendants cleared2011: 1 descendant cleared2021: 2 descendants cleared2009: 2 descendants cleared2013: 2 descendants cleared2020: 3 descendants cleared2018: 3 descendants cleared2017: 1 descendant cleared2015: 2 descendants cleared2016: 2 descendants cleared2022: 2 descendants cleared2019: 1 descendant cleared2023: 1 descendant cleared2024: 1 descendant cleared2026: 1 descendant cleared2025: 1 descendant clearedK003285 · Exac Trac 2.0 (Novalis Body Module) · Brainlab AG · 2001200020052010201520202025
Descendants, by generation 1 generation forward: 5 descendants2 generations forward: 14 descendants3 generations forward: 9 descendants4 generations forward: 5 descendants5 generations forward: 4 descendants6 generations forward: 2 descendants7 generations forward: 1 descendant8 generations forward: 1 descendant K003285 · Exac Trac 2.0 (Novalis Body Module) · Brainlab AG · 20010+5
  1. Root · 1 generation backK003285 Exac Trac 2.0 (Novalis Body Module)Brainlab AG · 2001
  2. This deviceK040585 Exactrac 4.0 and Exactrac X-Ray 6DBrainlab AG · 2004
  3. Descendant · cites it directly · 15 of its ownK072506 Exactrac 5.5Brainlab AG · 2007 · Recalled
  4. Descendant · cites it directly · 13 of its ownK072046 Exactrac 3RD Party, Exactrac X-Ray 6D 3RD Party, Exactrac OemBrainlab AG · 2007
  5. Descendant · cites it directly · 11 of its ownK060906 Calypso 4D Localization SystemCalypso Medical Technologies, Inc. · 2006
  6. Descendant · 2 generations on · 10 of its ownK122451 Exactrac VeroBrainlab AG · 2012 · Recalled
  7. Descendant · 2 generations on · 9 of its ownK080726 Calypso 4D Localization SystemCalypso Medical Technologies, Inc. · 2008

Showing 5 of 41 descendants. See all descendants

Descendants cleared per year

2006: 32007: 22008: 22009: 22010: 12011: 12012: 52013: 22014: 32015: 22016: 22017: 12018: 32019: 12020: 32021: 22022: 22023: 12024: 12025: 12026: 1
2006high 5 (2012) · low 1 (2010)2026

Most influential descendants

Showing 5 of 41 · See all
  • K072506Exactrac 5.5Brainlab AG · 2007 · cites it directly15descendants
  • K072046Exactrac 3RD Party, Exactrac X-Ray 6D 3RD Party, Exactrac OemBrainlab AG · 2007 · cites it directly13descendants
  • K060906Calypso 4D Localization SystemCalypso Medical Technologies, Inc. · 2006 · cites it directly11descendants
  • K122451Exactrac VeroBrainlab AG · 2012 · 2 generations on10descendants
  • K080726Calypso 4D Localization SystemCalypso Medical Technologies, Inc. · 2008 · 2 generations on9descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K003285Exac Trac 2.0 (Novalis Body Module)Brainlab AG2001—
0 (this device)K040585Exactrac 4.0 and Exactrac X-Ray 6DBrainlab AG2004—
+1K072506Exactrac 5.5Brainlab AG20071
+1K072046Exactrac 3RD Party, Exactrac X-Ray 6D 3RD Party, Exactrac OemBrainlab AG2007—
+1K060906Calypso 4D Localization SystemCalypso Medical Technologies, Inc.2006—
+2K122451Exactrac VeroBrainlab AG20122
+2K080726Calypso 4D Localization SystemCalypso Medical Technologies, Inc.2008—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200630
200720
200820
200920
201010
201110
201250
201320
201430
201520
201620
201710
201830
201910
202030
202120
202220
202310
202410
202510
202610
FIG. 1 — Lineage of K040585, 2001–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in IYE? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new IYE device

  1. #1 K252977 Halcyon, Ethos Radiotherapy System (5.0)score 18.8 · 18 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K003285Exac Trac 2.0 (Novalis Body Module)
Summary page 1
…Patient Positioning System / System, Radiation Therapy, Charged- Particle, Medical Predicate Device: ExacTrac (K003285) Device Classification Name: System, Radiation Therapy, Charged-Particle, Medical Regulatory Class: Class II X-ray Generator D…
Brainlab AG2001—

Also cleared against K003285: 5 other devices →

What descends from it? (41)

See all 41

5 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K072506Exactrac 5.5Brainlab AG200715
K072046Exactrac 3RD Party, Exactrac X-Ray 6D 3RD Party, Exactrac OemBrainlab AG200713
K060906Calypso 4D Localization SystemCalypso Medical Technologies, Inc.200611
K052212MIGUEDirex Systems Corp.20061
K061713MAGIS1;MAGIS2Direx Systems Corp.20060

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has no recall.
  • Of its descendants, K072506 (Brainlab AG, 2007) has gone furthest, with 15 descendants of its own.
  • 5 other devices also cite its predicate K003285.

How does its category compare?

All IYE devices

IYE Accelerator, Linear, Medical: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · IYE

12in 2025

2007: 232008: 142009: 202010: 232011: 112012: 282013: 182014: 202015: 202016: 212017: 232018: 212019: 192020: 202021: 192022: 122023: 182024: 92025: 122026 (partial year): 14
2007high 28 (2012) · low 9 (2024)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · IYE

170in 2025

2007: 44 days median2008: 69 days median2009: 63 days median2010: 74 days median2011: 94 days median2012: 106 days median2013: 88 days median2014: 100 days median2015: 108 days median2016: 97 days median2017: 94 days median2018: 58 days median2019: 83 days median2020: 67 days median2021: 86 days median2022: 172 days median2023: 129 days median2024: 239 days median2025: 170 days median2026 (partial year): 120 days median
2007high 239 (2024) · low 44 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · IYE

1in 2025

2007: 782008: 492009: 222010: 272011: 732012: 202013: 112014: 142015: 82016: 72017: 72018: 72019: 22020: 42021: 52022: 32023: 72024: 12025: 12026 (partial year): 4
2007high 78 (2007) · low 1 (2024)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · IYE

101in 2025

2007: 1552008: 1142009: 1742010: 2462011: 2802012: 1282013: 962014: 1242015: 1002016: 972017: 1252018: 852019: 912020: 742021: 682022: 662023: 1282024: 812025: 101
2007high 280 (2011) · low 66 (2022)2025

MAUDE reports naming product code IYE, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007234478155
2008146949114
2009206322174
2010237427246
2011119473280
20122810620128
201318881196
20142010014124
2015201088100
20162197797
201723947125
20182158785
20191983291
20202067474
20211986568
202212172366
2023181297128
20249239181
2025121701101
2026141204—

What is it indicated for?

ExacTrac 4.0 is a system that is intended to be used to place patients at the isocenter of a linear accelerator for stereotactic radiosurgery or radiotherapy procedures. The ExacTrac 4.0 system uses optical tracking of infrared reflecting markers and x-ray registration as the method of locating the position of the patient.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K040585: Exactrac 4.0 and Exactrac X-Ray 6D.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K040585

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026