510(k) Report

510(k) · Cleared

Cleared

Contour HA Coated Reconstruction Ring

K040680510(k) TraditionalCleared Jun 14, 200490-day reviewClass II21 CFR 888.3353

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Smith & Nephew, Inc. · MEH Prosthesis, Hip, Semi-Constrained, Uncemented, Metal / Polymer, Non-Porous, Calcium Phosphate

Cleared on Jun 14, 2004 as substantially equivalent to K962541 (Smith & Nephew Richards, Inc., 1996) and 2 other predicates after a 90-day review. Its family tree reaches back 1 generation to 1996. 6 later devices descend from it.

Decided
Jun 14, 2004
Review
90 days
Class
Class II
Product code
MEH
Recalls
None
Predicates
3

Its longest line of descent runs back 1 generation to K962007 (1996). 3 ancestors in all. 6 later devices descend from it, 3 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 1997: 1 other ancestor1996: 1 other ancestor2022: 1 descendant cleared2010: 1 descendant cleared2013: 1 descendant cleared2024: 2 descendants cleared2023: 1 descendant clearedReference device: K922621 · HA TI-Fit Acetabular and Femoral Component · Smith & Nephew Richards, Inc. · 1994Reference device: K990666 · Hydroxyapatite (HA) Reflection Acetabular Shell, Hydroxyapatite (HA) Reflection Interfit Shell · Smith & Nephew, Inc. · 1999 · recalledK962007 · Protrusion Cages · Depuy, Inc. · 19961995200020052010201520202025
Other ancestors, by generationDescendants, by generation 1 generation back: 2 other ancestors 1 generation forward: 3 descendants2 generations forward: 3 descendants K962007 · Protrusion Cages · Depuy, Inc. · 19960
  1. Root · 1 generation backK962007 Protrusion CagesDepuy, Inc. · 1996
  2. This deviceK040680 Contour HA Coated Reconstruction RingSmith & Nephew, Inc. · 2004
  3. Descendant · cites it directly · 3 of its ownK211176 Smith & Nephew Hip SystemsSmith & Nephew, Inc. · 2022 · Recalled
  4. Descendant · cites it directly · 1 of its ownK092098 Patient Specific Acetabular Reconstruction ProsthesisSmith & Nephew, Inc. · 2010
  5. Descendant · 2 generations on · 0 of its ownK240783 Anthology Hip Stems; CPCS Hip Stems; Femoral Heads; R3 Acetabular…Smith & Nephew, Inc. · 2024
  6. Descendant · 2 generations on · 0 of its ownK242375 OR3O Dual Mobility SystemSmith & Nephew, Inc. · 2024
  7. Descendant · 2 generations on · 0 of its ownK231448 TANDEM Hip SystemSmith & Nephew, Inc. · 2023 · Recalled

Showing 5 of 6 descendants. See all descendants

Descendants cleared per year

2010: 12013: 12022: 12023: 12024: 2
2010high 2 (2024) · low 0 (2011)2026

Most influential descendants

Showing 5 of 6 · See all
  • K211176Smith & Nephew Hip SystemsSmith & Nephew, Inc. · 2022 · cites it directly3descendants
  • K092098Patient Specific Acetabular Reconstruction ProsthesisSmith & Nephew, Inc. · 2010 · cites it directly1descendant
  • K240783Anthology Hip Stems; CPCS Hip Stems; Femoral Heads; R3 Acetabular Liners; Spectron Hip…Smith & Nephew, Inc. · 2024 · 2 generations on0descendants
  • K242375OR3O Dual Mobility SystemSmith & Nephew, Inc. · 2024 · 2 generations on0descendants
  • K231448TANDEM Hip SystemSmith & Nephew, Inc. · 2023 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K962007Protrusion CagesDepuy, Inc.1996—
0 (this device)K040680Contour HA Coated Reconstruction RingSmith & Nephew, Inc.2004—
+1K211176Smith & Nephew Hip SystemsSmith & Nephew, Inc.20221
+1K092098Patient Specific Acetabular Reconstruction ProsthesisSmith & Nephew, Inc.2010—
+2K240783Anthology Hip Stems; CPCS Hip Stems; Femoral Heads; R3 Acetabular Liners…Smith & Nephew, Inc.2024—
+2K242375OR3O Dual Mobility SystemSmith & Nephew, Inc.2024—
+2K231448TANDEM Hip SystemSmith & Nephew, Inc.20231

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199610
199710

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201010
201310
202210
202310
202420
FIG. 1 — Lineage of K040680, 1996–2024Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MEH? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MEH device

  1. #1 K210581 Actis DuoFix Hip Prosthesis- Collarlessscore 23.9 · 16 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K962541Reflection Acetabular Reinforcement Rings
Summary page 1
…BSTANTIAL EQUIVALENCE INFORMATION: The Contour HA Coated Reconstruction Ring is substantially equivalent to the Smith & Nephew Reflection Acetabular Reinforcement Rings (K962541), Osteonics Restoration Acetabular Ring (K970957), and DePuy Protrusio Cage (K962007). The Contour HA Coated Reconstruction Ring…
Smith & Nephew Richards, Inc.1996—
*K970957Osteonics Restoration Acetabular Ring
Summary page 1
…Coated Reconstruction Ring is substantially equivalent to the Smith & Nephew Reflection Acetabular Reinforcement Rings (K962541), Osteonics Restoration Acetabular Ring (K970957), and DePuy Protrusio Cage (K962007). The Contour HA Coated Reconstruction Ring has a HA coating that is substantially equivalent…
Osteonics Corp.1997—
*K962007Protrusion Cages
Summary page 1
…antially equivalent to the Smith & Nephew Reflection Acetabular Reinforcement Rings (K962541), Osteonics Restoration Acetabular Ring (K970957), and DePuy Protrusio Cage (K962007). The Contour HA Coated Reconstruction Ring has a HA coating that is substantially equivalent to the HA coating on the Smith & Ne…
Depuy, Inc.1996—
†K922621HA TI-Fit Acetabular and Femoral ComponentSmith & Nephew Richards, Inc.1994—
†K990666Hydroxyapatite (HA) Reflection Acetabular Shell, Hydroxyapatite (HA) Reflection Interfit…Smith & Nephew, Inc.19991

Also cleared against K962541: 4 other devices →

What descends from it? (6)

3 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K211176Smith & Nephew Hip SystemsSmith & Nephew, Inc.20223
K092098Patient Specific Acetabular Reconstruction ProsthesisSmith & Nephew, Inc.20101
K123598Smith & Nephew, Inc. Hip System InstrumentationSmith & Nephew, Inc.20130

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • None of the 3 ancestors has a recall.
  • Of its descendants, K211176 (Smith & Nephew, Inc., 2022) has gone furthest, with 3 descendants of its own.
  • 4 other devices also cite its predicate K962541.

How does its category compare?

All MEH devices

MEH Prosthesis, Hip, Semi-Constrained, Uncemented, Metal / Polymer, Non-Porous, Calcium Phosphate: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · MEH

5in 2025

2007: 22008: 62009: 62010: 52011: 52012: 62013: 12015: 22016: 62017: 32018: 22019: 12020: 32021: 32022: 32023: 22024: 62025: 52026 (partial year): 1
2007high 6 (2008) · low 0 (2014)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MEH

87in 2025

2008: 79 days median2009: 65 days median2010: 226 days median2011: 95 days median2012: 131 days median2016: 163 days median2017: 209 days median2020: 131 days median2021: 83 days median2022: 150 days median2024: 91 days median2025: 87 days median
2007high 226 (2010) · low 65 (2009)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MEH

1in 2025

2007: 32008: 802009: 512010: 162011: 42012: 32014: 12015: 12016: 42017: 12018: 32020: 12025: 12026 (partial year): 1
2007high 80 (2008) · low 0 (2013)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MEH

470in 2025

2007: 252008: 2612009: 5392010: 4622011: 4192012: 1,6062013: 1,2952014: 1,1962015: 4902016: 3472017: 3832018: 3372019: 3352020: 3382021: 3722022: 3162023: 3342024: 3542025: 470
2007high 1,606 (2012) · low 25 (2007)2025

MAUDE reports naming product code MEH, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—325
200867980261
200966551539
2010522616462
20115954419
2012613131,606
20131—01,295
20140—11,196
20152—1490
201661634347
201732091383
20182—3337
20191—0335
202031311338
20213830372
202231500316
20232—0334
20246910354
20255871470
20261—1—

What is it indicated for?

Total hip components are indicated for individuals undergoing primary or revision surgery where other treatments or devices have failed in rehabilitating hips damaged as a result of trauma, inflammatory joint disease such as rheumatoid arthritis; or noninflammatory degenerative joint disease (NIDJD) or any of its composite diagnoses such as osteoarthritis; avascular necrosis; traumatic arthritis; slipped capital epiphysis; fused hip; fracture of the…

Read the full statement (157 words)

Total hip components are indicated for individuals undergoing primary or revision surgery where other treatments or devices have failed in rehabilitating hips damaged as a result of trauma, inflammatory joint disease such as rheumatoid arthritis; or noninflammatory degenerative joint disease (NIDJD) or any of its composite diagnoses such as osteoarthritis; avascular necrosis; traumatic arthritis; slipped capital epiphysis; fused hip; fracture of the pelvis and diastrophic variant; old, remote osteomyelitis with an extended drainage-free period; nonunion; femoral neck fracture and trochanteric fractures of the proximal femur with head involvement that are unmanageable using other techniques; femoral osteotomy, or Girdlestone resection; fracture dislocation of the hip and correction of deformity.

Acetabular reinforcement and reconstruction rings are intended to be used in primary and revision surgeries where the acetabulum has the deficiencies of the acetabular roof, anterior or posterior pillar, medial wail deficiency, and/or protrusion as a result of the indications listed previously. The device is intended for single use.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K040680: Contour HA Coated Reconstruction Ring.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K040680

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026