Colleague Volumetric Infusion Pumps

K041191510(k) TraditionalCleared Jun 25, 200450-day reviewClass II21 CFR 880.5725Recalls 10

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Baxter Healthcare Corp · FRN Pump, Infusion

Cleared on Jun 25, 2004 after a 50-day review. The FDA summary names its predicate without a number. 1 later device descends from it. It has been recalled 10 times.

Decided
Jun 25, 2004
Review
50 days
Class
Class II
Product code
FRN
Recalls
10
Predicates
0

1 later device descends from it, 1 citing it directly.

Descendants, by year cleared 2007: 1 descendant cleared200020052010201520202025
  1. This deviceK041191 Colleague Volumetric Infusion PumpsBaxter Healthcare Corp · 2004
  2. Descendant · cites it directly · 0 of its ownK070125 Colleague Guardian Configuration Tool; Colleague DL2 Event History…Baxter Healthcare Corp · 2007

Most influential descendants

Showing 1 of 1 · See all
  • K070125Colleague Guardian Configuration Tool; Colleague DL2 Event History Download Software…Baxter Healthcare Corp · 2007 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K041191Colleague Volumetric Infusion PumpsBaxter Healthcare Corp2004—
+1K070125Colleague Guardian Configuration Tool; Colleague DL2 Event History Download…Baxter Healthcare Corp2007—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200710
FIG. 1 — Lineage of K041191, 2004–2007Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in FRN? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new FRN device

  1. #1 K253703 RemunityPRO+ Pump for Remodulin®…score 12.6 · 4 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*—Colleague Volumetric Infusion Pumps
Named without a submission number
—

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K070125Colleague Guardian Configuration Tool; Colleague DL2 Event History Download Software…Baxter Healthcare Corp20070

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Dec 6, 2006Not classifiedZ-0483-2007OtherBaxter has identified the potential for a corruption of the memory chip in the pump to occur due to linear accelerator radiation exposure. If corruption occurs, it could result in an interruption of therapy with an audible and visual…
Dec 6, 2006Not classifiedZ-0484-2007OtherBaxter has identified the potential for a corruption of the memory chip in the pump to occur due to linear accelerator radiation exposure. If corruption occurs, it could result in an interruption of therapy with an audible and visual…
Dec 13, 2005Not classifiedZ-0445-06Device DesignInterruption of therapy due to battery undercharging, the generation of air-in-line alarms due to IV administration set tugging, and gearbox wear; and underinfusion due to misalignment of the pump head components.
Dec 13, 2005Not classifiedZ-0444-06Device DesignInterruption of therapy due to battery undercharging, the generation of air-in-line alarms due to IV administration set tugging, and gearbox wear; and underinfusion due to misalignment of the pump head components.
Jul 20, 2005Not classifiedZ-1059-05Device DesignA hardware problem can cause internal communications errors which halt therapies, generate alarms and communication failure codes.
Jul 20, 2005Not classifiedZ-1060-05Device DesignA hardware problem can cause internal communications errors which halt therapies, generate alarms and communication failure codes.
Mar 15, 2005Not classifiedZ-1023-05Device DesignThe pumps may experience inadvertent power off, external communications port failures and electronic pump failure codes 402, 403, 533, 535, 599, 810:04 and 810:11.
Mar 15, 2005Not classifiedZ-1022-05Device DesignThe pumps may experience inadvertent power off, external communications port failures and electronic pump failure codes 402, 403, 533, 535, 599, 810:04 and 810:11.
Feb 25, 2005Not classifiedZ-1544-05Labeling designSwelling of the sealed lead-acid batteries in the infusion pump can cause internal pump damage, and excessive battery discharge can damage the batteries if the pump is left on battery power for an extended period of time after teh Battery…
Feb 25, 2005Not classifiedZ-1543-05Labeling designSwelling of the sealed lead-acid batteries in the infusion pump can cause internal pump damage, and excessive battery discharge can damage the batteries if the pump is left on battery power for an extended period of time after teh Battery…

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K070125 (Baxter Healthcare Corp, 2007) has gone furthest, with 0 descendants of its own.

How does its category compare?

All FRN devices

FRN Pump, Infusion: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · FRN

8in 2025

2007: 122008: 82009: 92010: 32011: 32012: 42013: 62014: 62015: 32016: 32017: 32018: 32019: 22020: 12021: 22022: 62023: 72024: 52025: 82026 (partial year): 2
2007high 12 (2007) · low 1 (2020)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FRN

172in 2025

2007: 102 days median2008: 89 days median2009: 66 days median2010: 93 days median2011: 103 days median2012: 217 days median2013: 312 days median2014: 172 days median2015: 232 days median2016: 301 days median2017: 305 days median2018: 267 days median2022: 268 days median2023: 265 days median2024: 103 days median2025: 172 days median
2007high 312 (2013) · low 66 (2009)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · FRN

7in 2025

2007: 152008: 242009: 1022010: 372011: 692012: 42, 2 Class I2013: 22, 3 Class I2014: 4, 3 Class I2015: 52016: 7, 1 Class I2017: 132018: 12019: 18, 1 Class I2020: 16, 5 Class I2021: 3, 2 Class I2022: 22023: 16, 10 Class I2024: 9, 4 Class I2025: 7, 4 Class I2026 (partial year): 11, 2 Class I
2007high 102 (2009) · low 1 (2018)2026

Class I (37 since 2007) Class II/III not classified

Adverse event reports per year · FRN

52,792in 2025

2007: 1,0862008: 8,2612009: 1,9522010: 6,1332011: 41,3672012: 15,4822013: 40,0822014: 94,1802015: 26,7422016: 16,5602017: 12,0602018: 16,5912019: 15,8502020: 94,1862021: 199,3422022: 888,0202023: 165,8382024: 57,7302025: 52,792
2007high 888,020 (2022) · low 1,086 (2007)2025

MAUDE reports naming product code FRN, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200712102151,086
2008889248,261
20099661021,952
2010393376,133
201131036941,367
2012421742 (2)15,482
2013631222 (3)40,082
201461724 (3)94,180
20153232526,742
201633017 (1)16,560
201733051312,060
20183267116,591
20192—18 (1)15,850
20201—16 (5)94,186
20212—3 (2)199,342
202262682888,020
2023726516 (10)165,838
202451039 (4)57,730
202581727 (4)52,792
20262—11 (2)—

What is it indicated for?

Baxter Colleague Infusion Pumps are designed to meet the fluid delivery needs of today's clinically evolving health care environment. These pumps can be utilized for continuous or intermittent delivery through acceptable routes of administration such as intravenous (IV), intra-arterial (IA), subcutaneous, epidural or irrigation of fluid spaces applications. Fluid delivery applications include: parenteral fluids, drugs and electrolytes (e.g.…

Read the full statement (152 words)

Baxter Colleague Infusion Pumps are designed to meet the fluid delivery needs of today's clinically evolving health care environment. These pumps can be utilized for continuous or intermittent delivery through acceptable routes of administration such as intravenous (IV), intra-arterial (IA), subcutaneous, epidural or irrigation of fluid spaces applications.

Fluid delivery applications include:

parenteral fluids, drugs and electrolytes (e.g. cardiovascular drugs, antibiotics, anesthetics, analgesics, etc.); and chemotherapy agents, total parenteral nutrition products, lipids, solutions for irrigation procedures, whole blood and blood products.

Colleague Infusion Pumps are designed to travel the continuum of care, following the patient into a variety of care areas, including, but not limited to:

Hospital: Post Anesthesia/Recovery - Blood Centers

General Floor Cardiac Cath Lab Nuclear Medicine

Medical/Surgical Emergency Room Hospice

Critical/Intensive Care Areas Burn/Trauma Units Subacute Facilities

Pediatrics/Neonatal Oncology Outpatient/Surgical Centers

Labor/Delivery/Post Partum Mobile Intensive Care Long Term Care

OR/Anesthesia Nursing Homes

Homecare*

*Colleague and Colleague CX pumps only.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K041191: Colleague Volumetric Infusion Pumps.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K041191

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.