510(k) · Cleared
ClearedDimension NT-Probnp Flex Reagent Cartridge Method, Dimension PBNP Calibrator, Models RF423, RC423
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Dade Behring, Inc. · NBC Test, Natriuretic Peptide
Cleared on Jul 20, 2004 as substantially equivalent to K032646 (Roche Diagnostics Corp., 2003) and 1 other predicate after a 54-day review. Its family tree reaches back 3 generations to 2000. 1 later device descends from it.
- Decided
- Jul 20, 2004
- Review
- 54 days
- Class
- Class II
- Product code
- NBC
- Recalls
- None
- Predicates
- 2
Its longest line of descent runs back 3 generations to DEN000010 (2000). 1 later device descends from it, 1 citing it directly.
- Root · 3 generations backDEN000010 Triage B-Type Natriuretic Peptide (BNP) TestBiosite Incorporated · 2000
- 2 generations backK022516 Elecsys Probnp ImmunoassayRoche Diagnostics Corp. · 2002
- 1 generation backK032646 Elecsys Probnp ImmunoassayRoche Diagnostics Corp. · 2003
- This deviceK041417 Dimension NT-Probnp Flex Reagent Cartridge Method, Dimension PBNP…Dade Behring, Inc. · 2004
- Descendant · cites it directly · 0 of its ownK071767 Dimensions PBNP Flex Reagent Cartridge, Model RF423ADade Behring, Inc. · 2007
Most influential descendants
Showing 1 of 1 · See all- K071767Dimensions PBNP Flex Reagent Cartridge, Model RF423ADade Behring, Inc. · 2007 · cites it directly0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −3 | DEN000010 | Triage B-Type Natriuretic Peptide (BNP) Test | Biosite Incorporated | 2000 | — |
| −2 | K022516 | Elecsys Probnp Immunoassay | Roche Diagnostics Corp. | 2002 | — |
| −1 | K032646 | Elecsys Probnp Immunoassay | Roche Diagnostics Corp. | 2003 | — |
| 0 (this device) | K041417 | Dimension NT-Probnp Flex Reagent Cartridge Method, Dimension PBNP Calibrator… | Dade Behring, Inc. | 2004 | — |
| +1 | K071767 | Dimensions PBNP Flex Reagent Cartridge, Model RF423A | Dade Behring, Inc. | 2007 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2007 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in NBC? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new NBC device
- #1 K262109 Access NT-proBNPscore 13.8 · 7 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (2)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K032646 | Elecsys Probnp ImmunoassaySummary page 1…FDA Reviewers" - 11/30/2000 Predicate Device(s): Roche Diagnostics Elecsys® proBNP immunoassay and CalSet calibrator (K032646/K022516) Device Description(s): Method The Dade Behring Dimension® NT-proBNP (PBNP) Flex® reagent cartridge method is an in vit… | 2003 |
| * | K022516 | Elecsys Probnp ImmunoassaySummary page 1…ewers" - 11/30/2000 Predicate Device(s): Roche Diagnostics Elecsys® proBNP immunoassay and CalSet calibrator (K032646/K022516) Device Description(s): Method The Dade Behring Dimension® NT-proBNP (PBNP) Flex® reagent cartridge method is an in vitro diagn… | 2002 |
What descends from it? (1)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K071767 | Dimensions PBNP Flex Reagent Cartridge, Model RF423A | 2007 | 0 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 4 years and passes through 3 companies; a new generation was cleared every 12 months on median.
- None of the 3 ancestors has a recall.
- Of its descendants, K071767 (Dade Behring, Inc., 2007) has gone furthest, with 0 descendants of its own.
- 7 other devices also cite its predicate K032646.
How does its category compare?
All NBC devicesNBC Test, Natriuretic Peptide: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · NBC
1in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · NBC
126in 2008
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · NBC
1in 2020
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · NBC
17in 2025
MAUDE reports naming product code NBC, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 2 | — | 0 | 17 |
| 2008 | 7 | 126 | 0 | 15 |
| 2009 | 0 | — | 0 | 35 |
| 2010 | 1 | — | 1 | 61 |
| 2011 | 0 | — | 0 | 53 |
| 2012 | 0 | — | 2 | 23 |
| 2013 | 0 | — | 0 | 13 |
| 2014 | 0 | — | 1 | 70 |
| 2015 | 0 | — | 1 | 43 |
| 2016 | 0 | — | 0 | 31 |
| 2017 | 0 | — | 0 | 9 |
| 2018 | 0 | — | 1 | 7 |
| 2019 | 0 | — | 0 | 9 |
| 2020 | 1 | — | 1 | 6 |
| 2021 | 2 | — | 0 | 0 |
| 2022 | 1 | — | 0 | 4 |
| 2023 | 2 | — | 0 | 26 |
| 2024 | 1 | — | 0 | 14 |
| 2025 | 1 | — | 0 | 17 |
| 2026 | 4 | 94 | 0 | — |
What is it indicated for?
The Dade Behring Dimension® PBNP Flex® reagent cartridge method is an in vitro diagnostic assay for the quantitative determination of N-terminal pro-brain natriuretic peptide (NT-proBNP) in human plasma. Measurements of NT-proBNP are used as an aid in the diagnosis of individuals suspected of having congestive heart failure.
The Dade Behring Dimension® PBNP Calibrator is intended to be used to calibrate the N-terminal pro-brain natriuretic peptide (PBNP) method for the Dade Behring Dimension® clinical chemistry system.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K041417 · printed Nov 6, 2026
Cite this page
510(k) Report. “K041417: Dimension NT-Probnp Flex Reagent Cartridge Method, Dimension PBNP Calibrator, Models RF423, RC423.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K041417
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026