510(k) Report

510(k) · Cleared

Cleared

Excella-M Spinal System

K042143510(k) TraditionalCleared Oct 7, 200459-day reviewClass II21 CFR 888.3050

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Innovasis, Inc. · KWP Appliance, Fixation, Spinal Interlaminal

Cleared on Oct 7, 2004 as substantially equivalent to K994217 (Blackstone Medical, Inc., 2000) and 3 other predicates after a 59-day review. Its family tree reaches back 3 generations to 1996. 6 later devices descend from it.

Decided
Oct 7, 2004
Review
59 days
Class
Class II
Product code
KWP
Recalls
None
Predicates
4

Its longest line of descent runs back 3 generations to K955348 (1996). 10 ancestors in all, the oldest K933881 (1994). 6 later devices descend from it, 2 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2001: 1 other ancestor2000: 1 other ancestor1999: 1 other ancestor1998: 1 other ancestor1995: 1 other ancestor1994: 2 other ancestors2014: 1 descendant cleared2007: 1 descendant cleared2010: 1 descendant cleared2024: 1 descendant cleared2016: 1 descendant cleared2025: 1 descendant clearedK955348 · Titanium Moss Miami Spinal System · Depuy, Inc. · 1996K964024 · Depuy Motech Titanium Moss Miami Spinal System · Depuy, Inc. · 1997K992168 · Moss Miami 6.35MM Polyaxial Screw · Depuyacromed · 19991990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 3 other ancestors2 generations back: 4 other ancestors 1 generation forward: 2 descendants2 generations forward: 3 descendants3 generations forward: 1 descendant K992168 · Moss Miami 6.35MM Polyaxial Screw · Depuyacromed · 1999K964024 · Depuy Motech Titanium Moss Miami Spinal System · Depuy, Inc. · 1997K955348 · Titanium Moss Miami Spinal System · Depuy, Inc. · 19960
  1. Root · 3 generations backK955348 Titanium Moss Miami Spinal SystemDepuy, Inc. · 1996
  2. 2 generations backK964024 Depuy Motech Titanium Moss Miami Spinal SystemDepuy, Inc. · 1997
  3. 1 generation backK992168 Moss Miami 6.35MM Polyaxial ScrewDepuyacromed · 1999
  4. This deviceK042143 Excella-M Spinal SystemInnovasis, Inc. · 2004
  5. Descendant · cites it directly · 5 of its ownK071921 Innovasis Excella Spinal System, Excella-M (Monoaxial Screws)…Innovasis, Inc. · 2007
  6. Descendant · 2 generations on · 4 of its ownK102248 Excella II Spinal System Model EC2-00Innovasis, Inc. · 2010 · Recalled
  7. Descendant · cites it directly · 3 of its ownK140238 Excella Iii-D Spinal Deformity SystemInnovasis, Inc. · 2014 · Recalled
  8. Descendant · 2 generations on · 1 of its ownK241276 Vector™ Pedicle Screw SystemInnovasis, Inc. · 2024 · Recalled
  9. Descendant · 3 generations on · 0 of its ownK251073 Innovasis Navigation Instruments (Vector G-E Navigation Instruments…Innovasis, Inc. · 2025 · Recalled

Showing 5 of 6 descendants. See all descendants

Descendants cleared per year

2007: 12010: 12014: 12016: 12024: 12025: 1
2007high 1 (2007) · low 0 (2008)2026

Most influential descendants

Showing 5 of 6 · See all
  • K071921Innovasis Excella Spinal System, Excella-M (Monoaxial Screws), Excella-P (Polyaxial…Innovasis, Inc. · 2007 · cites it directly5descendants
  • K102248Excella II Spinal System Model EC2-00Innovasis, Inc. · 2010 · 2 generations on4descendants
  • K140238Excella Iii-D Spinal Deformity SystemInnovasis, Inc. · 2014 · cites it directly3descendants
  • K241276Vector™ Pedicle Screw SystemInnovasis, Inc. · 2024 · 2 generations on1descendant
  • K251073Innovasis Navigation Instruments (Vector G-E Navigation Instruments and the Excella G-E…Innovasis, Inc. · 2025 · 3 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K955348Titanium Moss Miami Spinal SystemDepuy, Inc.1996—
−2K964024Depuy Motech Titanium Moss Miami Spinal SystemDepuy, Inc.1997—
−1K992168Moss Miami 6.35MM Polyaxial ScrewDepuyacromed1999—
0 (this device)K042143Excella-M Spinal SystemInnovasis, Inc.2004—
+1K071921Innovasis Excella Spinal System, Excella-M (Monoaxial Screws), Excella-P…Innovasis, Inc.2007—
+2K102248Excella II Spinal System Model EC2-00Innovasis, Inc.20103
+1K140238Excella Iii-D Spinal Deformity SystemInnovasis, Inc.20142
+2K241276Vector™ Pedicle Screw SystemInnovasis, Inc.20241
+3K251073Innovasis Navigation Instruments (Vector G-E Navigation Instruments and the…Innovasis, Inc.20251

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199420
199510
199810
199910
200010
200110

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200710
201010
201410
201610
202410
202510
FIG. 1 — Lineage of K042143, 1996–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in KWP? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (4)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K994217Blackstone Spinal Fixation System
Summary page 1
…1 CRF 888.3070) Device Product Code: KWQ, KWP, MNH, [MNI. The Panel code is 87. Substantially Equivalent Devices: Blackstone Spinal Fixation System (k994217) DePuy Acromed Moss Miami system (k992 168) Synthes Universal Spinal…
Blackstone Medical, Inc.2000—
*K992168Moss Miami 6.35MM Polyaxial Screw
Summary page 1
…Panel code is 87. Substantially Equivalent Devices: Blackstone Spinal Fixation System (k994217) DePuy Acromed Moss Miami system (k992 168) Synthes Universal Spinal System (k990745) Interpore Cross Synergy IQ…
Depuyacromed1999—
*K990745Modification to Synthes Universal Spinal System
Summary page 1
…Spinal Fixation System (k994217) DePuy Acromed Moss Miami system (k992 168) Synthes Universal Spinal System (k990745) Interpore Cross Synergy IQ Spinal System (k012871) Device Description: The INNOVAS…
Synthes Spine1999—
*K012871Synergy TI Integral Open Screws Models # 6193, 6194, 6195,6196, 6173, 6174, 6175, 6176…
Summary page 1
…s Miami system (k992 168) Synthes Universal Spinal System (k990745) Interpore Cross Synergy IQ Spinal System (k012871) Device Description: The INNOVASIS 'Excella-M' Spinal System is a 6-4 Titanium Alloy device comprised of a variet…
Interpore Cross Intl.2001—

Also cleared against K994217: 9 other devices →

What descends from it? (6)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K071921Innovasis Excella Spinal System, Excella-M (Monoaxial Screws), Excella-P (Polyaxial…Innovasis, Inc.20075
K140238Excella Iii-D Spinal Deformity SystemInnovasis, Inc.20143

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 8 years and passes through 3 companies; a new generation was cleared every 2.5 years on median.
  • None of the 10 ancestors has a recall.
  • Of its descendants, K071921 (Innovasis, Inc., 2007) has gone furthest, with 5 descendants of its own.
  • 9 other devices also cite its predicate K994217.

How does its category compare?

All KWP devices

KWP Appliance, Fixation, Spinal Interlaminal: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · KWP

9in 2015

2007: 142008: 132009: 122010: 142011: 122012: 182013: 122014: 132015: 9
2007high 18 (2012) · low 0 (2016)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · KWP

113in 2015

2007: 96 days median2008: 50 days median2009: 89 days median2010: 186 days median2011: 67 days median2012: 112 days median2013: 99 days median2014: 138 days median2015: 113 days median
2007high 186 (2010) · low 50 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · KWP

2in 2022

2007: 22008: 12009: 232010: 22011: 62012: 12013: 32015: 12016: 32018: 12019: 22022: 2
2007high 23 (2009) · low 0 (2014)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · KWP

494in 2025

2007: 2102008: 5942009: 6822010: 4742011: 7922012: 9182013: 1,0902014: 1,0222015: 1,3482016: 1,3792017: 8642018: 6572019: 5182020: 7962021: 5252022: 3352023: 3322024: 4362025: 494
2007high 1,379 (2016) · low 210 (2007)2025

MAUDE reports naming product code KWP, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200714962210
200813501594
2009128923682
2010141862474
201112676792
2012181121918
2013129931,090
20141313801,022
2015911311,348
20160—31,379
20170—0864
20180—1657
20190—2518
20200—0796
20210—0525
20220—2335
20230—0332
20240—0436
20250—0494
20260—0—

What is it indicated for?

The Innovasis 'Excella-M' Spinal System is intended for use in the non-cervical area of the spine. The Innovasis 'Excella-M' Spinal System, when used for pedicle screw fixation is intended only for patients: a) Having severe spondylolisthesis (Grade 3 & 4) at the L5-S1 joint; b) Who are receiving fusion using autogenous bone graft only; c) Who are having the device fixed or attached to the lumbar sacral spine (L3 and below); and d) Who are having the…

Read the full statement (299 words)

The Innovasis 'Excella-M' Spinal System is intended for use in the non-cervical area of the spine.

The Innovasis 'Excella-M' Spinal System, when used for pedicle screw fixation is intended only for patients:

a) Having severe spondylolisthesis (Grade 3 & 4) at the L5-S1 joint;

b) Who are receiving fusion using autogenous bone graft only;

c) Who are having the device fixed or attached to the lumbar sacral spine (L3 and below); and

d) Who are having the device removed after the development of a solid fusion mass.

The Innovasis 'Excella-M' Spinal System, when used as a pedicle screw system in skeletally mature patients, is intended to provide immobilization and stabilization of spinal segments, as an adjunct to fusion, in treatment of the following acute and chronic deformities of the thoracic, lumbar, and sacral spine:

a) Degenerative spondylolisthesis with objective evidence of neurologic impairment; b) Fracture; c) Dislocation; d) Scoliosis; e) Kyphosis; f) Spinal tumor; and g) Previous failed fusion (pseudarthrosis).

The Innovasis 'Excella-M' Spinal System, when used for anterolateral non-pedicle fixation, is intended for the following indications:

a) Degenerative disc disease (DDD) (defined as back pain of discogenic origin with degenerative disc confirmed by patient history and radiographic studies); b) Spinal stenosis; c) Spondylolisthesis; d) Spinal deformities (i.e. scoliosis, kyphosis, and/or lordosis); e) Pseudarthrosis; f) Tumor; g) Trauma (i.e. fracture or dislocation); and h) Previous failed fusion.

The Innovasis 'Excella-M' Spinal System, when used for posterior non-pedicle screw fixation to the non-cervical spine, is intended for the following indications:

a) Degenerative disc disease (DDD) (defined as back pain of discogenic origin with degenerative disc confirmed by patient history and radiographic studies); b) Spinal stenosis; c) Spondylolisthesis; d) Spinal deformities (i.e. scoliosis, kyphosis and/or lordosis); e) Pseudarthrosis; f) Tumor; g) Trauma (i.e. fracture or dislocation); and h) Previous failed fusion

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K042143: Excella-M Spinal System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K042143

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026