510(k) Report

510(k) · Cleared

Cleared

Zimmer M/L Taper Hip Prosthesis with Calcicoat Ceramic Coating

K042337510(k) SpecialCleared Nov 4, 200466-day reviewClass II21 CFR 888.3358

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Zimmer, Inc. · LPH Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented

Cleared on Nov 4, 2004 as substantially equivalent to K032726 (Zimmer, Inc., 2003) after a 66-day review. Its family tree reaches back 5 generations to 1985. 1 of the 27 devices in its family, counting itself, has a Class I recall. 11 later devices descend from it.

Decided
Nov 4, 2004
Review
66 days
Class
Class II
Product code
LPH
Recalls
None
Predicates
1

Its longest line of descent runs back 5 generations to K850055 (1985). 15 ancestors in all. 11 later devices descend from it, 4 citing it directly. 1 of the 27 devices in this family, counting this one, has a Class I recall.

Other ancestors, by year clearedDescendants, by year cleared 2002: 1 other ancestor1997: 1 other ancestor1994: 5 other ancestors1990: 1 other ancestor1996: 1 other ancestor1987: 1 other ancestor2020: 3 descendants cleared2007: 2 descendants cleared, 1 with a Class I recall12006: 1 descendant cleared2016: 1 descendant cleared2011: 1 descendant cleared2019: 1 descendant cleared2008: 1 descendant cleared2025: 1 descendant clearedK850055 · Profile Femoral Hip · Depuy, Inc. · 1985K961378 · Delta Hip Prosthesis · Zimmer, Inc. · 1996 · recalled×2: 2 generations cleared close together, K992667 (1999), K994286 (2000) K032726 · Zimmer M/L Taper Hip Prosthesis, 7711 Series · Zimmer, Inc. · 2003 · recalled1990200020102020
Other ancestors, by generationDescendants, by generation 2 generations back: 3 other ancestors3 generations back: 5 other ancestors4 generations back: 2 other ancestors 1 generation forward: 4 descendants2 generations forward: 5 descendants, 1 with a Class I recall13 generations forward: 2 descendants K032726 · Zimmer M/L Taper Hip Prosthesis, 7711 Series · Zimmer, Inc. · 2003 · recalledK994286 · ZMR Hip System-Porous Revision · Zimmer, Inc. · 2000 · recalledK992667 · ZMR Hip System-Revision Taper · Zimmer, Inc. · 1999 · recalledK961378 · Delta Hip Prosthesis · Zimmer, Inc. · 1996 · recalledK850055 · Profile Femoral Hip · Depuy, Inc. · 1985−50
  1. Root · 5 generations backK850055 Profile Femoral HipDepuy, Inc. · 1985
  2. 4 generations backK961378 Delta Hip ProsthesisZimmer, Inc. · 1996 · Recalled
  3. 3 generations backK992667 ZMR Hip System-Revision TaperZimmer, Inc. · 1999 · Recalled
  4. 2 generations backK994286 ZMR Hip System-Porous RevisionZimmer, Inc. · 2000 · Recalled
  5. 1 generation backK032726 Zimmer M/L Taper Hip Prosthesis, 7711 SeriesZimmer, Inc. · 2003 · Recalled
  6. This deviceK042337 Zimmer M/L Taper Hip Prosthesis with Calcicoat Ceramic CoatingZimmer, Inc. · 2004
  7. Descendant · cites it directly · 5 of its ownK063251 Zimmer M/L Taper Hip Prosthesis with Modular Neck TechnologyZimmer, Inc. · 2007 · Recalled
  8. Descendant · 2 generations on · 3 of its ownK081007 Zimmer M/L Taper Hip Prosthesis with Kinectiv Technology SystemZimmer, Inc. · 2008
  9. Descendant · 2 generations on · 3 of its ownK071856 Zimmer M/L Taper Hip Prosthesis with Kinectiv Technology System…Zimmer, Inc. · 2007 · Recalled (Class I)
  10. Descendant · cites it directly · 3 of its ownK060040 Zimmer M/L Taper Hip ProsthesisZimmer, Inc. · 2006 · Recalled
  11. Descendant · cites it directly · 2 of its ownK192660 Zimmer M/L Taper Hip ProsthesisZimmer, Inc. · 2020

Showing 5 of 11 descendants. See all descendants

Descendants cleared per year

2006: 12007: 22008: 12011: 12016: 12019: 12020: 32025: 1
2006high 3 (2020) · low 0 (2009)2026

Class I recalls in this family

Most influential descendants

Showing 5 of 11 · See all
  • K063251Zimmer M/L Taper Hip Prosthesis with Modular Neck TechnologyZimmer, Inc. · 2007 · cites it directly5descendants
  • K081007Zimmer M/L Taper Hip Prosthesis with Kinectiv Technology SystemZimmer, Inc. · 2008 · 2 generations on3descendants
  • K071856Zimmer M/L Taper Hip Prosthesis with Kinectiv Technology System, Model (S) 7848 Series (…Zimmer, Inc. · 2007 · 2 generations on3descendants
  • K060040Zimmer M/L Taper Hip ProsthesisZimmer, Inc. · 2006 · cites it directly3descendants
  • K192660Zimmer M/L Taper Hip ProsthesisZimmer, Inc. · 2020 · cites it directly2descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−5K850055Profile Femoral HipDepuy, Inc.1985—
−4K961378Delta Hip ProsthesisZimmer, Inc.19964
−3K992667ZMR Hip System-Revision TaperZimmer, Inc.19991
−2K994286ZMR Hip System-Porous RevisionZimmer, Inc.200011
−1K032726Zimmer M/L Taper Hip Prosthesis, 7711 SeriesZimmer, Inc.20033
0 (this device)K042337Zimmer M/L Taper Hip Prosthesis with Calcicoat Ceramic CoatingZimmer, Inc.2004—
+1K063251Zimmer M/L Taper Hip Prosthesis with Modular Neck TechnologyZimmer, Inc.20074
+2K081007Zimmer M/L Taper Hip Prosthesis with Kinectiv Technology SystemZimmer, Inc.2008—
+2K071856Zimmer M/L Taper Hip Prosthesis with Kinectiv Technology System, Model (S)…Zimmer, Inc.2007Class I
+1K060040Zimmer M/L Taper Hip ProsthesisZimmer, Inc.20062
+1K192660Zimmer M/L Taper Hip ProsthesisZimmer, Inc.2020—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198710
199010
199450
199610
199710
200210

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200610
200721
200810
201110
201610
201910
202030
202510
FIG. 1 — Lineage of K042337, 1985–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LPH device

  1. #1 K233498 Stryker Orthopaedics Hip Systems Labeling Updatescore 24.2 · 20 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K032726Zimmer M/L Taper Hip Prosthesis, 7711 Series
Summary page 1
…LPH Predicate Device: Zimmer MN/L Taper Hip Prosthesis, manufactured by Zimmer, Inc., K032726, cleared October 22, 2003. Device Description: T…
Zimmer, Inc.20033

Also cleared against K032726: 6 other devices →

What descends from it? (11)

See all 11

4 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K063251Zimmer M/L Taper Hip Prosthesis with Modular Neck TechnologyZimmer, Inc.20075
K060040Zimmer M/L Taper Hip ProsthesisZimmer, Inc.20063
K192660Zimmer M/L Taper Hip ProsthesisZimmer, Inc.20202
K161830Zimmer M/L Taper Hip ProsthesisZimmer, Inc.20160

Has anything in its family been recalled? (1 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K071856Zimmer M/L Taper Hip Prosthesis with Kinectiv Technology System, Model (S) 7848 Series ( Modular Necks)…Zimmer, Inc. · 2007 · 2 generations on · ◆ in the 2007 descendants bar of FIG. 11 Class I recall

What does this lineage say?

  • The line of descent spans 19 years and passes through 2 companies; a new generation was cleared every 3.0 years on median.
  • 7 of the 15 ancestors have a recall of any class.
  • Of its descendants, K063251 (Zimmer, Inc., 2007) has gone furthest, with 5 descendants of its own.
  • 6 other devices also cite its predicate K032726.

How does its category compare?

All LPH devices

LPH Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · LPH

12in 2025

2007: 102008: 102009: 32010: 152011: 162012: 252013: 112014: 202015: 182016: 102017: 122018: 92019: 222020: 72021: 82022: 142023: 102024: 62025: 122026 (partial year): 8
2007high 25 (2012) · low 3 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LPH

153in 2025

2007: 116 days median2008: 86 days median2009: 112 days median2010: 100 days median2011: 110 days median2012: 76 days median2013: 135 days median2014: 129 days median2015: 111 days median2016: 150 days median2017: 121 days median2018: 145 days median2019: 164 days median2020: 164 days median2021: 410 days median2022: 247 days median2023: 111 days median2024: 92 days median2025: 153 days median2026 (partial year): 256 days median
2007high 410 (2021) · low 76 (2012)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · LPH

4in 2025

2007: 162008: 12009: 22010: 222011: 262012: 302013: 92014: 32015: 12016: 82017: 142018: 22019: 82020: 62021: 42022: 22023: 22024: 12025: 42026 (partial year): 2
2007high 30 (2012) · low 1 (2008)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · LPH

6,163in 2025

2007: 5092008: 7062009: 1,1562010: 2,0072011: 3,3202012: 3,7852013: 5,0022014: 5,1632015: 5,8302016: 4,9002017: 5,3122018: 5,9542019: 7,1302020: 5,4292021: 5,9782022: 5,2232023: 5,3452024: 5,6262025: 6,163
2007high 7,130 (2019) · low 509 (2007)2025

MAUDE reports naming product code LPH, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071011616509
200810861706
2009311221,156
201015100222,007
201116110263,320
20122576303,785
20131113595,002
20142012935,163
20151811115,830
20161015084,900
201712121145,312
2018914525,954
20192216487,130
2020716465,429
2021841045,978
20221424725,223
20231011125,345
202469215,626
20251215346,163
202682562—

What is it indicated for?

Total hip replacement for the following: severe hip pain and disability due to rheumatoid arthritis, osteoarthritis, traumatic arthritis, polyarthritis, collagen disorders, avascular necrosis of the femoral head, nonunion of previous fractures of the femur; congenital hip dysplasia, protrusio acetabuli, slipped capital femoral epiphysis; disability due to previous fusion; previously failed endoprostheses, and/or total hip components in the affected…

Read the full statement (133 words)

Total hip replacement for the following: severe hip pain and disability due to rheumatoid arthritis, osteoarthritis, traumatic arthritis, polyarthritis, collagen disorders, avascular necrosis of the femoral head, nonunion of previous fractures of the femur; congenital hip dysplasia, protrusio acetabuli, slipped capital femoral epiphysis; disability due to previous fusion; previously failed endoprostheses, and/or total hip components in the affected extremity and acute femoral neck fractures.

Hemi-hip replacement for the following: fracture dislocation of the hip; elderly, debilitated patients when a total hip replacement is contraindicated; irreducible fractures in which adequate fixation cannot be obtained; certain high subcapital fractures and comminuted femoral neck fractures in the aged; nonunion of femoral neck fractures; secondary avascular necrosis of the femoral head; pathological fractures of the femoral neck; and osteoarthritis in which the femoral head is primarily affected.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K042337: Zimmer M/L Taper Hip Prosthesis with Calcicoat Ceramic Coating.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K042337

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026