510(k) · Cleared
ClearedZimmer M/L Taper Hip Prosthesis
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Zimmer, Inc. · LZO Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented
Cleared on Feb 28, 2020 as substantially equivalent to K032726 (Zimmer, Inc., 2003) and 2 other predicates after a 156-day review. Its family tree reaches back 7 generations to 1985. 2 later devices descend from it.
- Decided
- Feb 28, 2020
- Review
- 156 days
- Class
- Class II
- Product code
- LZO
- Recalls
- None
- Predicates
- 3
Its longest line of descent runs back 7 generations to K850055 (1985). 23 ancestors in all. 2 later devices descend from it, 1 citing it directly.
- Root · 7 generations backK850055 Profile Femoral HipDepuy, Inc. · 1985
- 6 generations backK961378 Delta Hip ProsthesisZimmer, Inc. · 1996 · Recalled
- 5 generations backK992667 ZMR Hip System-Revision TaperZimmer, Inc. · 1999 · Recalled
- 4 generations backK994286 ZMR Hip System-Porous RevisionZimmer, Inc. · 2000 · Recalled
- 3 generations backK032726 Zimmer M/L Taper Hip Prosthesis, 7711 SeriesZimmer, Inc. · 2003 · Recalled
- 2 generations backK042337 Zimmer M/L Taper Hip Prosthesis with Calcicoat Ceramic CoatingZimmer, Inc. · 2004
- 1 generation backK060040 Zimmer M/L Taper Hip ProsthesisZimmer, Inc. · 2006 · Recalled
- This deviceK192660 Zimmer M/L Taper Hip ProsthesisZimmer, Inc. · 2020
- Descendant · cites it directly · 1 of its ownK200823 Zimmer, Inc. Hip Joint Prostheses MR Labeling IZimmer, Inc. · 2020 · Recalled
- Descendant · 2 generations on · 0 of its ownK250834 Zimmer Biomet Ceramic Heads (22.2mm diameter)Zimmer Biomet · 2025
Most influential descendants
Showing 2 of 2 · See allView FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −7 | K850055 | Profile Femoral Hip | Depuy, Inc. | 1985 | — |
| −6 | K961378 | Delta Hip Prosthesis | Zimmer, Inc. | 1996 | 4 |
| −5 | K992667 | ZMR Hip System-Revision Taper | Zimmer, Inc. | 1999 | 1 |
| −4 | K994286 | ZMR Hip System-Porous Revision | Zimmer, Inc. | 2000 | 11 |
| −3 | K032726 | Zimmer M/L Taper Hip Prosthesis, 7711 Series | Zimmer, Inc. | 2003 | 3 |
| −2 | K042337 | Zimmer M/L Taper Hip Prosthesis with Calcicoat Ceramic Coating | Zimmer, Inc. | 2004 | — |
| −1 | K060040 | Zimmer M/L Taper Hip Prosthesis | Zimmer, Inc. | 2006 | 2 |
| 0 (this device) | K192660 | Zimmer M/L Taper Hip Prosthesis | Zimmer, Inc. | 2020 | — |
| +1 | K200823 | Zimmer, Inc. Hip Joint Prostheses MR Labeling I | Zimmer, Inc. | 2020 | 1 |
| +2 | K250834 | Zimmer Biomet Ceramic Heads (22.2mm diameter) | Zimmer Biomet | 2025 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1987 | 1 | 0 |
| 1990 | 1 | 0 |
| 1994 | 6 | 0 |
| 1996 | 3 | 0 |
| 1997 | 2 | 0 |
| 2002 | 1 | 0 |
| 2003 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2020 | 1 | 0 |
| 2025 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in LZO? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new LZO device
- #1 K192827 Quadra-Pscore 19.3 · 10 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (3)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K032726 | Zimmer M/L Taper Hip Prosthesis, 7711 SeriesSummary page 4…Uncemented, Metal/Polymer, Non-Porous, Calcium- Phosphate (21 CFR 888.3353 Hip joint metal/ceramic/polymer semi-constrained cemented or nonporous uncemented prosthesis) K032726 ZIMMER M/L Zimmer, Inc TAPER HIP PROSTHESIS, 7711 SERIES K042337 ZIMMER M/L Zimmer, Inc TAPER HIP PROSTHESIS WITH CALCICOAT CERAM… | 2003 |
| * | K042337 | Zimmer M/L Taper Hip Prosthesis with Calcicoat Ceramic CoatingSummary page 4…888.3353 Hip joint metal/ceramic/polymer semi-constrained cemented or nonporous uncemented prosthesis) K032726 ZIMMER M/L Zimmer, Inc TAPER HIP PROSTHESIS, 7711 SERIES K042337 ZIMMER M/L Zimmer, Inc TAPER HIP PROSTHESIS WITH CALCICOAT CERAMIC COATING K060040 ZIMMER M/L Zimmer, Inc Device… | 2004 |
| * | K060040 | Zimmer M/L Taper Hip ProsthesisSummary page 4…cemented prosthesis) K032726 ZIMMER M/L Zimmer, Inc TAPER HIP PROSTHESIS, 7711 SERIES K042337 ZIMMER M/L Zimmer, Inc TAPER HIP PROSTHESIS WITH CALCICOAT CERAMIC COATING K060040 ZIMMER M/L Zimmer, Inc Device Description Indications for Use: Summary of Technological Characteristics: TAPER… | 2006 |
What descends from it? (2)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K200823 | Zimmer, Inc. Hip Joint Prostheses MR Labeling I | 2020 | 1 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 35 years and passes through 2 companies; a new generation was cleared every 3.0 years on median.
- 12 of the 22 ancestors have a recall of any class.
- Of its descendants, K200823 (Zimmer, Inc., 2020) has gone furthest, with 1 descendant of its own.
- 6 other devices also cite its predicate K032726.
How does its category compare?
All LZO devicesLZO Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented: FDA decisions, review times, recalls and adverse event reports over 20 years. 2020, this device’s year, is highlighted.
FDA decisions per year · LZO
14in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · LZO
119in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · LZO
1in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · LZO
3,244in 2025
MAUDE reports naming product code LZO, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 9 | 87 | 2 | 138 |
| 2008 | 11 | 63 | 13 | 125 |
| 2009 | 7 | 83 | 42 | 189 |
| 2010 | 15 | 78 | 0 | 394 |
| 2011 | 13 | 87 | 10 | 544 |
| 2012 | 14 | 98 | 14 | 963 |
| 2013 | 26 | 100 | 0 | 1,370 |
| 2014 | 13 | 85 | 1 | 1,477 |
| 2015 | 12 | 115 | 1 | 1,348 |
| 2016 | 10 | 177 | 9 | 1,728 |
| 2017 | 16 | 257 | 5 | 2,165 |
| 2018 | 18 | 163 | 2 | 3,133 |
| 2019 | 28 | 109 | 4 | 3,066 |
| 2020 | 18 | 112 | 3 | 1,963 |
| 2021 | 12 | 170 | 0 | 2,199 |
| 2022 | 11 | 279 | 4 | 1,985 |
| 2023 | 10 | 122 | 2 | 2,066 |
| 2024 | 11 | 111 | 1 | 2,586 |
| 2025 | 14 | 119 | 1 | 3,244 |
| 2026 | 9 | 102 | 0 | — |
What is it indicated for?
Total hip replacement for the following: severe hip pain and disability due to rheumatoid arthritis, osteoarthritis, traumatic arthritis, polyarthritis, collagen disorders, avascular necrosis of the femoral head, nonunion of previous fractures of the femur; congenital hip dysplasia, protrusio acetabuli, slipped capital femoral epiphysis; disability due to previous fusion; previously failed endoprostheses, and/or total hip components in the affected…
Read the full statement (141 words)
Total hip replacement for the following: severe hip pain and disability due to rheumatoid arthritis, osteoarthritis, traumatic arthritis, polyarthritis, collagen disorders, avascular necrosis of the femoral head, nonunion of previous fractures of the femur; congenital hip dysplasia, protrusio acetabuli, slipped capital femoral epiphysis; disability due to previous fusion; previously failed endoprostheses, and/or total hip components in the affected extremity and acute femoral neck fractures.
Hemi-hip replacement for the following: fracture dislocation of the hip; elderly, debilitated patients when a total hip replacement is contraindicated; irreducible fractures in which adequate fixation cannot be obtained; certain high subcapital fractures and comminuted femoral neck fractures in the aged; nonunion of femoral neck fractures; secondary avascular necrosis of the femoral head; pathological fractures of the femoral neck; and osteoarthritis in which the femoral head is primarily affected.
The femoral stem is for cementless use only.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K192660 · printed Nov 6, 2026
Cite this page
510(k) Report. “K192660: Zimmer M/L Taper Hip Prosthesis.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K192660
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026