510(k) · Cleared
Recalled · Class II · 2014Emg Model SUA01 Suction Unit
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Emg Technology Co., Ltd. · JCX Apparatus, Suction, Ward Use, Portable, Ac-Powered
Cleared on Dec 16, 2004 after a 108-day review. FDA’s file for it is a 510(k) statement, which names no predicate. 1 later device descends from it. It has been recalled once.
- Decided
- Dec 16, 2004
- Review
- 108 days
- Class
- Class II
- Product code
- JCX
- Recalls
- 1
- Predicates
- 0
1 later device descends from it, 1 citing it directly.
- This deviceK042349 Emg Model SUA01 Suction UnitEmg Technology Co., Ltd. · 2004
- Descendant · cites it directly · 0 of its ownK130001 Care SU01A Suction AspiratorFoshan Care Medical Technology Co., Ltd. · 2013
Most influential descendants
Showing 1 of 1 · See all- K130001Care SU01A Suction AspiratorFoshan Care Medical Technology Co., Ltd. · 2013 · cites it directly0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| 0 (this device) | K042349 | Emg Model SUA01 Suction Unit | Emg Technology Co., Ltd. | 2004 | — |
| +1 | K130001 | Care SU01A Suction Aspirator | Foshan Care Medical Technology Co., Ltd. | 2013 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2013 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in JCX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new JCX device
- #1 K250964 Protable Phlegm Suction Unit (JMA D01)score 12.2 · 4 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against?
FDA’s file for it is a 510(k) statement, which names no predicate.
What descends from it? (1)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K130001 | Care SU01A Suction Aspirator | 2013 | 0 |
Has anything in its family been recalled? (0 Class I)
Recalls of this device
| Date | Class | Recall | Root cause | Reason |
|---|---|---|---|---|
| Aug 3, 2014 | Class II | Z-2642-2014 | Nonconforming Material/Component | suction canister lids may have occluded ports. |
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Of its descendants, K130001 (Foshan Care Medical Technology Co., Ltd., 2013) has gone furthest, with 0 descendants of its own.
How does its category compare?
All JCX devicesJCX Apparatus, Suction, Ward Use, Portable, Ac-Powered: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · JCX
2in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · JCX
30in 2019
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · JCX
1in 2020
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · JCX
45in 2025
MAUDE reports naming product code JCX, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 0 | — | 0 | 48 |
| 2008 | 4 | 43 | 3 | 57 |
| 2009 | 1 | — | 0 | 34 |
| 2010 | 1 | — | 0 | 7 |
| 2011 | 2 | — | 2 | 9 |
| 2012 | 2 | — | 0 | 18 |
| 2013 | 5 | 144 | 2 | 12 |
| 2014 | 4 | 106 | 0 | 68 |
| 2015 | 0 | — | 0 | 118 |
| 2016 | 2 | — | 0 | 119 |
| 2017 | 2 | — | 1 | 102 |
| 2018 | 2 | — | 0 | 170 |
| 2019 | 3 | 30 | 0 | 132 |
| 2020 | 0 | — | 1 | 89 |
| 2021 | 0 | — | 0 | 227 |
| 2022 | 1 | — | 0 | 215 |
| 2023 | 1 | — | 0 | 187 |
| 2024 | 1 | — | 0 | 103 |
| 2025 | 2 | — | 0 | 45 |
| 2026 | 1 | — | 1 | — |
What is it indicated for?
The Model SUAO1 Suction unit is intended for professional use to remove infectious materials from wounds or fluids from a patients airway or respiratory support unit. The intended large population for this device is both adult and pediatric patients.
Indications for use as stated in the FDA 510(k) statement.
https://510kreport.com/device/K042349 · printed Nov 5, 2026
Cite this page
510(k) Report. “K042349: Emg Model SUA01 Suction Unit.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K042349
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026