510(k) Report

510(k) · Cleared

Cleared

Iiizarov Pulley System

K042436510(k) TraditionalCleared Oct 7, 200429-day reviewClass II21 CFR 888.3030

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Smith & Nephew, Inc. · KTT Appliance, Fixation, Nail/Blade/Plate Combination, Multiple Component

Cleared on Oct 7, 2004 as substantially equivalent to K870961 (Richards Medical Co., Inc., 1987) and 1 other predicate after a 29-day review. Its family tree reaches back 1 generation to 1987. 8 later devices descend from it.

Decided
Oct 7, 2004
Review
29 days
Class
Class II
Product code
KTT
Recalls
None
Predicates
3

Its longest line of descent runs back 1 generation to K870961 (1987). 2 ancestors in all. 8 later devices descend from it, 3 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2000: 1 other ancestor2012: 1 descendant cleared2020: 2 descendants cleared2025: 3 descendants cleared2026: 1 descendant cleared2024: 1 descendant clearedK870961 · Richards External Fixation System · Richards Medical Co., Inc. · 19871990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 1 other ancestor 1 generation forward: 3 descendants2 generations forward: 5 descendants K870961 · Richards External Fixation System · Richards Medical Co., Inc. · 19870
  1. Root · 1 generation backK870961 Richards External Fixation SystemRichards Medical Co., Inc. · 1987
  2. This deviceK042436 Iiizarov Pulley SystemSmith & Nephew, Inc. · 2004
  3. Descendant · cites it directly · 6 of its ownK120871 Smith & Nephew, Inc. External Fixation System InstrumentationSmith & Nephew, Inc. · 2012
  4. Descendant · cites it directly · 5 of its ownK201253 Modular Rail System, TAYLOR SPATIAL FRAME External Fixator, JET-X…Smith & Nephew · 2020
  5. Descendant · 2 generations on · 1 of its ownK241563 Extremity Medical External Fixation SystemExtremity Medical, LLC · 2025
  6. Descendant · 2 generations on · 0 of its ownK253291 Excelsior SystemBlue Ocean Global · 2026
  7. Descendant · 2 generations on · 0 of its ownK253202 Hoffmann LRF SystemStryker GmbH · 2025

Showing 5 of 8 descendants. See all descendants

Descendants cleared per year

2012: 12020: 22024: 12025: 32026: 1
2012high 3 (2025) · low 0 (2013)2026

Most influential descendants

Showing 5 of 8 · See all
  • K120871Smith & Nephew, Inc. External Fixation System InstrumentationSmith & Nephew, Inc. · 2012 · cites it directly6descendants
  • K201253Modular Rail System, TAYLOR SPATIAL FRAME External Fixator, JET-X Fixator, ILIZAROV…Smith & Nephew · 2020 · cites it directly5descendants
  • K241563Extremity Medical External Fixation SystemExtremity Medical, LLC · 2025 · 2 generations on1descendant
  • K253291Excelsior SystemBlue Ocean Global · 2026 · 2 generations on0descendants
  • K253202Hoffmann LRF SystemStryker GmbH · 2025 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K870961Richards External Fixation SystemRichards Medical Co., Inc.1987—
0 (this device)K042436Iiizarov Pulley SystemSmith & Nephew, Inc.2004—
+1K120871Smith & Nephew, Inc. External Fixation System InstrumentationSmith & Nephew, Inc.2012—
+1K201253Modular Rail System, TAYLOR SPATIAL FRAME External Fixator, JET-X Fixator…Smith & Nephew2020—
+2K241563Extremity Medical External Fixation SystemExtremity Medical, LLC2025—
+2K253291Excelsior SystemBlue Ocean Global2026—
+2K253202Hoffmann LRF SystemStryker GmbH2025—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200010

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201210
202020
202410
202530
202610
FIG. 1 — Lineage of K042436, 1987–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in KTT? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new KTT device

  1. #1 K242861 TrueLok Elevatescore 21.3 · 14 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary; numbers the summary cites that cannot be its predicate are marked – and kept off the family tree.

TypeNumberDeviceApplicantDecidedRecalls
*K870961Richards External Fixation System
Summary page 2
…nt stiffness). SUBSTANTIAL EQUIVALENCE INFORMATION: The Ilizarov Pulley System is similar to the Smith & Nephew (formerly Richards) External Fixation System (llizarov) (K870961) and Smith & Nephew External Fixation System (K994143) in that all the devices are used for the same indications and consist of h…
Richards Medical Co., Inc.1987—
*K994143Smith & Nephew External Fixation System [Unilateral (Linear) & Multilateral (Circular)…
Summary page 2
…he Ilizarov Pulley System is similar to the Smith & Nephew (formerly Richards) External Fixation System (llizarov) (K870961) and Smith & Nephew External Fixation System (K994143) in that all the devices are used for the same indications and consist of half pins, wires, rings and various components to const…
Smith & Nephew, Inc.200019
Kept off the family treeK87516Smith & Nephew Orthopaedic Cable System
Number could not be read
Summary page 2
…port the bone segment. The Ilizarov Pulley System includes a stainless steel cable. The stainless steel cable is similar to the Smith & Nephew Orthopaedic Cable System (K87516) in that both cables are made of stainless steel and the diameters are similar (1.5mm). The Ilizarov Pulley System cable is longe…

Also cleared against K870961: 9 other devices →

What descends from it? (8)

3 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K120871Smith & Nephew, Inc. External Fixation System InstrumentationSmith & Nephew, Inc.20126
K201253Modular Rail System, TAYLOR SPATIAL FRAME External Fixator, JET-X Fixator, ILIZAROV…Smith & Nephew20205
K202762Circular Fixation with Balanced Cable TransportSmith & Nephew, Inc.20200

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • 1 of the 2 ancestors has a recall of any class.
  • Of its descendants, K120871 (Smith & Nephew, Inc., 2012) has gone furthest, with 6 descendants of its own.
  • 9 other devices also cite its predicate K870961.

How does its category compare?

All KTT devices

KTT Appliance, Fixation, Nail/Blade/Plate Combination, Multiple Component: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · KTT

10in 2025

2007: 92008: 112009: 112010: 122011: 102012: 92013: 72014: 142015: 122016: 102017: 112018: 62019: 82020: 92021: 102022: 32023: 72024: 52025: 102026 (partial year): 5
2007high 14 (2014) · low 3 (2022)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · KTT

88in 2025

2007: 55 days median2008: 73 days median2009: 94 days median2010: 148 days median2011: 157 days median2012: 140 days median2013: 87 days median2014: 129 days median2015: 60 days median2016: 142 days median2017: 184 days median2018: 149 days median2019: 110 days median2020: 200 days median2021: 83 days median2022: 25 days median2023: 29 days median2024: 90 days median2025: 88 days median2026 (partial year): 68 days median
2007high 200 (2020) · low 25 (2022)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · KTT

2in 2021

2007: 22008: 12009: 22010: 12012: 42013: 72017: 12018: 142019: 32021: 22026 (partial year): 11
2007high 14 (2018) · low 0 (2011)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · KTT

673in 2025

2007: 452008: 662009: 452010: 1212011: 1962012: 5272013: 8982014: 4452015: 4012016: 4002017: 4852018: 5972019: 8002020: 9422021: 9612022: 6272023: 5542024: 5232025: 673
2007high 961 (2021) · low 45 (2007)2025

MAUDE reports naming product code KTT, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007955245
20081173166
20091194245
2010121481121
2011101570196
201291404527
20137877898
2014141290445
201512600401
2016101420400
2017111841485
2018614914597
201981103800
202092000942
202110832961
20223250627
20237290554
20245900523
202510880673
202656811—

What is it indicated for?

External fixation devices are used on adults or pediatric patients as required. External fixation systems consist of various components that are used to build fixator assemblies unique to the patient's need. These devices are modular, therefore, a multitude of different fixator frame configurations are possible. External fixation devices are used for the following indications: 1. Post-Traumatic joint contracture which has resulted in loss of range of…

Read the full statement (254 words)

External fixation devices are used on adults or pediatric patients as required. External fixation systems consist of various components that are used to build fixator assemblies unique to the patient's need. These devices are modular, therefore, a multitude of different fixator frame configurations are possible. External fixation devices are used for the following indications:

1. Post-Traumatic joint contracture which has resulted in loss of range of motion

2. Fractures and disease which generally may result in joint contractures or loss of range of motion and fractures requiring distraction

3. Open and closed fracture fixation

4. Pseudoarthrosis of long bones

5. Limb lengthening by epiphyseal or metaphyseal distraction (not applicable for COMPASS Universal Hinge or JET-XTh Fixator)

6. Correction of bony or soft tissue deformities (not applicable for COMPASS Universal Hinge)

7. Correction of segmental bony or soft tissue defects

8. Joint arthrodesis

9. Infected fractures or nonunions

10. Mini external fixator systems are indicated for the management of comminuted intra-articular fractures of the distal radius.

11. Calandruccio devices are indicated for arthrodesis of the ankle or subtalar joints, as well as some select fractures, nonunion, or osteotomy of the distal tibia; and acute transverse fractures or nonunion of the distal tibia.

The indications for use listed above cover many of the external fixation systems marketed by Smith & Nephew, The indications for the Ilizarov Pulley System are pseudoarthrosis of long bones, included as number 4 above. These indications are similar to the indications of the predicate devices. The device is intended for single use.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K042436: Iiizarov Pulley System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K042436

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026