510(k) Report

510(k) · Cleared

Recalled · Class I · 2018

Jaundice Meter, Model JM 103

K042522510(k) TraditionalCleared Jul 6, 2005293-day reviewClass I21 CFR 862.1113Recalls 1 (1 Class I)

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Draeger Medical Infant Care, Inc. · MQM Bilirubin (Total And Unbound) In The Neonate Test System

Cleared on Jul 6, 2005 as substantially equivalent to K021622 (Hill-Rom Air-Shields, 2003) after a 293-day review. Its family tree reaches back 3 generations to 1981. 2 of the 5 devices in its family, counting itself, have a Class I recall. 1 later device descends from it. It has been recalled once, including a Class I recall.

Decided
Jul 6, 2005
Review
293 days
Class
Class I
Product code
MQM
Recalls
1 (1 Class I)
Predicates
1

Its longest line of descent runs back 3 generations to P810007 (1981). 1 later device descends from it, 1 citing it directly. 2 of the 5 devices in this family, counting this one, have a Class I recall.

Descendants, by year cleared 2014: 1 descendant cleared, 1 with a Class I recall1P810007 · Jaundice Meter 101 · Narco Scientific · 1981K972309 · JM-102 Jaundice Meter · Air-Shields, Inc. · 1998K021622 · Hill-Rom Air Shields/Minolta Jaundice Meter, Model JM-103 · Hill-Rom Air-Shields · 200319801990200020102020
  1. Root · 3 generations backP810007 Jaundice Meter 101Narco Scientific · 1981
  2. 2 generations backK972309 JM-102 Jaundice MeterAir-Shields, Inc. · 1998
  3. 1 generation backK021622 Hill-Rom Air Shields/Minolta Jaundice Meter, Model JM-103Hill-Rom Air-Shields · 2003
  4. This deviceK042522 Jaundice Meter, Model JM 103Draeger Medical Infant Care, Inc. · 2005
  5. Descendant · cites it directly · 0 of its ownK133175 Draeger Jaundice Meter JM-105Draeger Medical Systems, Inc. · 2014 · Recalled (Class I)

Class I recalls in this family

Most influential descendants

Showing 1 of 1 · See all
  • K133175Draeger Jaundice Meter JM-105Draeger Medical Systems, Inc. · 2014 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3P810007Jaundice Meter 101Narco Scientific1981—
−2K972309JM-102 Jaundice MeterAir-Shields, Inc.1998—
−1K021622Hill-Rom Air Shields/Minolta Jaundice Meter, Model JM-103Hill-Rom Air-Shields2003—
0 (this device)K042522Jaundice Meter, Model JM 103Draeger Medical Infant Care, Inc.2005—
+1K133175Draeger Jaundice Meter JM-105Draeger Medical Systems, Inc.2014Class I

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201411
FIG. 1 — Lineage of K042522, 1981–2014Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

2 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K021622Hill-Rom Air Shields/Minolta Jaundice Meter, Model JM-103
Summary page 1
…Test Systems 21 CFR 862.113 Bilirubin in the Neonatal Test System, MVQM, Class I Performance Standards: None applicable Predicate Device: K021622 JM 103 Jaundice Meter Device Description The JM-1 03 Jaundice Meter is designed to provide a transcutaneous measurement…
Hill-Rom Air-Shields2003—

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K133175Draeger Jaundice Meter JM-105 Class IDraeger Medical Systems, Inc.20140

Has anything in its family been recalled? (2 Class I)

Recalls of this device

DateClassRecallRoot causeReason
May 15, 2018Class IZ-2046-2018Device DesignUsers have misinterpreted the display for out of range measurement indicated by the blinking" ---" to mean a zero measurement.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K133175Draeger Jaundice Meter JM-105Draeger Medical Systems, Inc. · 2014 · Cites it directly · ◆ in the 2014 descendants bar of FIG. 11 Class I recall

What does this lineage say?

  • The line of descent spans 24 years and passes through 4 companies; a new generation was cleared every 4.5 years on median.
  • None of the 3 ancestors has a recall.
  • Of its descendants, K133175 (Draeger Medical Systems, Inc., 2014) has gone furthest, with 0 descendants of its own.

How does its category compare?

All MQM devices

MQM Bilirubin (Total And Unbound) In The Neonate Test System: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · MQM

1in 2017

2008: 12011: 12014: 22017: 1
2007high 2 (2014) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MQM

Too few MQM 510(k)s in any year since 2007 to give a median.

Recalls per year · MQM

No recall names MQM since 2007.

Adverse event reports per year · MQM

2in 2025

2007: 52008: 32010: 42011: 32012: 42014: 12015: 12016: 12017: 12018: 52019: 62020: 12021: 12023: 142024: 172025: 2
2007high 17 (2024) · low 0 (2009)2025

MAUDE reports naming product code MQM, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—05
20081—03
20090—00
20100—04
20111—03
20120—04
20130—00
20142—01
20150—01
20160—01
20171—01
20180—05
20190—06
20200—01
20210—01
20220—00
20230—014
20240—017
20250—02
20260—0—

What is it indicated for?

The Jaundice Meter (JM-103) is a non-invasive transcutaneous bilirubinometer. It measures yellowness of subcutaneous tissue in newborn infants. The unit provides a visual digital measurement that has been shown to correlate with serum bilirubin in newborn infants. The device is intended for use in hospitals, clinics or doctor's offices under a physicians supervision / direction to assist clinicians in monitoring of newborn infants. The device is not…

Read the full statement (163 words)

The Jaundice Meter (JM-103) is a non-invasive transcutaneous bilirubinometer. It measures yellowness of subcutaneous tissue in newborn infants. The unit provides a visual digital measurement that has been shown to correlate with serum bilirubin in newborn infants.

The device is intended for use in hospitals, clinics or doctor's offices under a physicians supervision / direction to assist clinicians in monitoring of newborn infants. The device is not intended as a standalone for diagnosis of hyperbilirubinemia. It is to be used in conjunction with other clinical signs and laboratory measurements.

Newborn infants whose JM-103 Jaundice Meter test results are indicative of hyperbilirubinemia should be evaluated by their physician(s) for appropriate patient management. Specific neonatal patient Bilirubin levels should be confirmed by other methods, such as serum bilirubin, prior to treatment determinations.

The JM 103 is a prescription Medical Device

The JM 103 is not intended for home use.

The JM 103 may only be used at the sternum measurement site for Physician's office applications.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K042522: Jaundice Meter, Model JM 103.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K042522

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026