Liberty System

K043074510(k) TraditionalCleared Feb 22, 2005106-day reviewClass II21 CFR 870.2340Recalls 1

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Inovise Medical, Inc. · DPS Electrocardiograph

Cleared on Feb 22, 2005 as substantially equivalent to K032145 (Inovise Medical, Inc., 2003) and 1 other predicate after a 106-day review. Its family tree reaches back 3 generations to 1992. 2 later devices descend from it. It has been recalled once.

Decided
Feb 22, 2005
Review
106 days
Class
Class II
Product code
DPS
Recalls
1
Predicates
2

Its longest line of descent runs back 3 generations to K920626 (1992). 4 ancestors in all. 2 later devices descend from it, 2 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2000: 1 other ancestor2007: 1 descendant cleared2005: 1 descendant clearedK920626 · Model Eli 200 Electrocardiograph · Mortara Instrument, Inc. · 1992×2: 2 generations cleared close together, K031182 (2003), K032145 (2003) 1990200020102020
Other ancestors, by generationDescendants, by generation 2 generations back: 1 other ancestor 1 generation forward: 2 descendants K032145 · Audicor Upgrade System · Inovise Medical, Inc. · 2003K031182 · Eli 200+ Audicor · Mortara Instrument, Inc. · 2003K920626 · Model Eli 200 Electrocardiograph · Mortara Instrument, Inc. · 19920
  1. Root · 3 generations backK920626 Model Eli 200 ElectrocardiographMortara Instrument, Inc. · 1992
  2. 2 generations backK031182 Eli 200+ AudicorMortara Instrument, Inc. · 2003
  3. 1 generation backK032145 Audicor Upgrade SystemInovise Medical, Inc. · 2003
  4. This deviceK043074 Liberty SystemInovise Medical, Inc. · 2005
  5. Descendant · cites it directly · 1 of its ownK051450 Extended Measurements SystemInovise Medical, Inc. · 2005
  6. Descendant · cites it directly · 0 of its ownK070136 Audicor 200 System, Models 200D and 200SInovise Medical, Inc. · 2007

Most influential descendants

Showing 2 of 2 · See all
  • K051450Extended Measurements SystemInovise Medical, Inc. · 2005 · cites it directly1descendant
  • K070136Audicor 200 System, Models 200D and 200SInovise Medical, Inc. · 2007 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K920626Model Eli 200 ElectrocardiographMortara Instrument, Inc.1992—
−2K031182Eli 200+ AudicorMortara Instrument, Inc.2003—
−1K032145Audicor Upgrade SystemInovise Medical, Inc.2003—
0 (this device)K043074Liberty SystemInovise Medical, Inc.2005—
+1K051450Extended Measurements SystemInovise Medical, Inc.2005—
+1K070136Audicor 200 System, Models 200D and 200SInovise Medical, Inc.2007—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200010

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200510
200710
FIG. 1 — Lineage of K043074, 1992–2007Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DPS? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DPS device

  1. #1 K212112 Cardiologs Holter Platformscore 18.6 · 5 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K032145Audicor Upgrade System
Summary page 1
…for Safety Substantial The Inovise Medical Liberty System is substantially equivalent to the Audicor Equivalence: Cardiograph Expansion system (K032145) and the Mortara Instrument ELI 200+ SumnmayS~afetyandEffectiveness…
Inovise Medical, Inc.2003—
*K031182Eli 200+ Audicor
Summary page 2
…stem 510(k) Submission with Audicor Electrocardiograph (K031 182). Technological The Liberty System and the predicate device are technologically equivalent in that Characteristics: both acqui…
Mortara Instrument, Inc.2003—

Also cleared against K032145: 2 other devices →

What descends from it? (2)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K051450Extended Measurements SystemInovise Medical, Inc.20051
K070136Audicor 200 System, Models 200D and 200SInovise Medical, Inc.20070

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Jan 12, 2003Not classifiedZ-0565-06OtherUse of the AUDICOR 200 D in-line with a defibrillator/monitor resulted in interruption of pacing therapy to a patient when the AUDICOR 200 D stopped working due to low battery power.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 13 years and passes through 2 companies; a new generation was cleared every 1.3 years on median.
  • None of the 4 ancestors has a recall.
  • Of its descendants, K051450 (Inovise Medical, Inc., 2005) has gone furthest, with 1 descendant of its own.
  • 2 other devices also cite its predicate K032145.

How does its category compare?

All DPS devices

DPS Electrocardiograph: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · DPS

6in 2025

2007: 112008: 132009: 142010: 112011: 222012: 122013: 102014: 112015: 82016: 112017: 92018: 142019: 32020: 62021: 52022: 62023: 102024: 82025: 62026 (partial year): 6
2007high 22 (2011) · low 3 (2019)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DPS

163in 2025

2007: 87 days median2008: 31 days median2009: 84 days median2010: 104 days median2011: 154 days median2012: 117 days median2013: 134 days median2014: 253 days median2015: 178 days median2016: 229 days median2017: 177 days median2018: 221 days median2019: 178 days median2020: 224 days median2021: 135 days median2022: 244 days median2023: 236 days median2024: 260 days median2025: 163 days median2026 (partial year): 258 days median
2007high 260 (2024) · low 31 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DPS

3in 2025

2007: 22009: 12010: 22011: 12019: 92020: 22021: 12022: 12023: 32024: 4, 1 Class I2025: 32026 (partial year): 4
2007high 9 (2019) · low 0 (2008)2026

Class I (1 since 2007) Class II/III not classified

Adverse event reports per year · DPS

55in 2025

2007: 92008: 172009: 142010: 212011: 1212012: 562013: 152014: 152015: 302016: 122017: 152018: 192019: 272020: 592021: 242022: 592023: 542024: 642025: 55
2007high 121 (2011) · low 9 (2007)2025

MAUDE reports naming product code DPS, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007118729
20081331017
20091484114
201011104221
2011221541121
201212117056
201310134015
201411253015
20158178030
201611229012
20179177015
201814221019
20193178927
20206224259
20215135124
20226244159
202310236354
202482604 (1)64
20256163355
202662584—

What is it indicated for?

The Liberty System, when used with Audicor Sensors on the chest wall, is intended for use in acquiring, analyzing and reporting ECG and heart sound data and to provide interpretation of the data in an integrated COR report for consideration by physicians. The Liberty System can be used as an add-on device to work in conjunction with select cardiographs, defibrillators, and patient monitors; or as a stand-alone electrocardiograph. The interpretations of…

Read the full statement (123 words)

The Liberty System, when used with Audicor Sensors on the chest wall, is intended for use in acquiring, analyzing and reporting ECG and heart sound data and to provide interpretation of the data in an integrated COR report for consideration by physicians.

The Liberty System can be used as an add-on device to work in conjunction with select cardiographs, defibrillators, and patient monitors; or as a stand-alone electrocardiograph. The interpretations of ECG and heart sound data offered by the device are only significant when used in conjunction with physician over read as well as consideration of other relevant patient data.

The device is intended for use only under the direct supervision of a physician, and is for use on adults (> 18 years).

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K043074: Liberty System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K043074

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026