510(k) Report

510(k) · Cleared

Cleared

Endoassist

K043284510(k) TraditionalCleared Feb 25, 200591-day reviewClass II21 CFR 876.1500

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Armstrong Healthcare Limited · GCJ Laparoscope, General & Plastic Surgery

Cleared on Feb 25, 2005 as substantially equivalent to K973249 (Armstrong Healthcare, Ltd., 1997) and 2 other predicates after a 91-day review. Its family tree reaches back 5 generations to 1993. 2 later devices descend from it.

Decided
Feb 25, 2005
Review
91 days
Class
Class II
Product code
GCJ
Recalls
None
Predicates
3

Its longest line of descent runs back 5 generations to K931783 (1993). 7 ancestors in all, the oldest K922626 (1992). 2 later devices descend from it, 1 citing it directly.

  1. Root · 5 generations backK931783 Aesop (Automated Endoscopic System for Optimal PosComputer Motion, Inc. · 1993
  2. 4 generations backK960655 Aesop System and AccessoriesComputer Motion, Inc. · 1996
  3. 3 generations backK963126 Aesop System and AccessoriesComputer Motion, Inc. · 1997
  4. 2 generations backK972699 Aesop 3000 System and AccessoriesComputer Motion, Inc. · 1997
  5. 1 generation backK023735 Lapman Laparoscope Manipulator System and Accessories, Model 900-001Medsys, S.A. · 2003
  6. This deviceK043284 EndoassistArmstrong Healthcare Limited · 2005
  7. Descendant · cites it directly · 1 of its ownK090340 FreehandProsurgics Limited · 2009
  8. Descendant · 2 generations on · 0 of its ownK102179 Enview (TM)Carefusion 2200 · 2010

Most influential descendants

Showing 2 of 2 · See all
  • K090340FreehandProsurgics Limited · 2009 · cites it directly1descendant
  • K102179Enview (TM)Carefusion 2200 · 2010 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−5K931783Aesop (Automated Endoscopic System for Optimal PosComputer Motion, Inc.1993—
−4K960655Aesop System and AccessoriesComputer Motion, Inc.1996—
−3K963126Aesop System and AccessoriesComputer Motion, Inc.1997—
−2K972699Aesop 3000 System and AccessoriesComputer Motion, Inc.1997—
−1K023735Lapman Laparoscope Manipulator System and Accessories, Model 900-001Medsys, S.A.2003—
0 (this device)K043284EndoassistArmstrong Healthcare Limited2005—
+1K090340FreehandProsurgics Limited2009—
+2K102179Enview (TM)Carefusion 22002010—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199210
199710

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200910
201010
FIG. 1 — Lineage of K043284, 1993–2010Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in GCJ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GCJ device

  1. #1 K214046 780 nm 1688 4K Camera System, 780 nm L11 LED…score 21.4 · 21 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K973249Endoassist
Summary page 1
…r The classification name is rigid endoscope accessory The classification group code is GCJ per CFR Section 21 876.1500 Predicate Devices EndoAssist K973249, AESOP 3000 K972699, Lapman K023735 Description of Device EndoAssist is a head-controlled Endoscopic camera manipulato…
Armstrong Healthcare, Ltd.1997—
*K972699Aesop 3000 System and Accessories
Summary page 1
…ation name is rigid endoscope accessory The classification group code is GCJ per CFR Section 21 876.1500 Predicate Devices EndoAssist K973249, AESOP 3000 K972699, Lapman K023735 Description of Device EndoAssist is a head-controlled Endoscopic camera manipulator. It is intended fo…
Computer Motion, Inc.1997—
*K023735Lapman Laparoscope Manipulator System and Accessories, Model 900-001
Summary page 1
…gid endoscope accessory The classification group code is GCJ per CFR Section 21 876.1500 Predicate Devices EndoAssist K973249, AESOP 3000 K972699, Lapman K023735 Description of Device EndoAssist is a head-controlled Endoscopic camera manipulator. It is intended for use in mi…
Medsys, S.A.2003—

What descends from it? (2)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K090340FreehandProsurgics Limited20091

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 12 years and passes through 3 companies; a new generation was cleared every 1.6 years on median.
  • None of the 7 ancestors has a recall.
  • Of its descendants, K090340 (Prosurgics Limited, 2009) has gone furthest, with 1 descendant of its own.

How does its category compare?

All GCJ devices

GCJ Laparoscope, General & Plastic Surgery: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · GCJ

21in 2025

2007: 182008: 192009: 212010: 242011: 152012: 172013: 152014: 192015: 262016: 272017: 202018: 212019: 152020: 282021: 182022: 202023: 312024: 292025: 212026 (partial year): 26
2007high 31 (2023) · low 15 (2011)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GCJ

108in 2025

2007: 42 days median2008: 73 days median2009: 85 days median2010: 122 days median2011: 113 days median2012: 88 days median2013: 93 days median2014: 90 days median2015: 76 days median2016: 99 days median2017: 77 days median2018: 88 days median2019: 60 days median2020: 61 days median2021: 116 days median2022: 103 days median2023: 109 days median2024: 90 days median2025: 108 days median2026 (partial year): 122 days median
2007high 122 (2010) · low 42 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · GCJ

5in 2025

2007: 122008: 162009: 62010: 302011: 92012: 12013: 7, 1 Class I2014: 22016: 52017: 12018: 12022: 12023: 12025: 52026 (partial year): 1
2007high 30 (2010) · low 0 (2015)2026

Class I (1 since 2007) Class II/III not classified

Adverse event reports per year · GCJ

5,860in 2025

2007: 1,6392008: 1,3192009: 1,9952010: 2,6572011: 2,1332012: 1,5262013: 1,5652014: 1,7142015: 1,7102016: 2,0802017: 3,4682018: 2,5622019: 2,5782020: 2,6182021: 3,4312022: 3,9452023: 6,0022024: 6,0472025: 5,860
2007high 6,047 (2024) · low 1,319 (2008)2025

MAUDE reports naming product code GCJ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071842121,639
20081973161,319
2009218561,995
201024122302,657
20111511392,133
2012178811,526
201315937 (1)1,565
2014199021,714
2015267601,710
2016279952,080
2017207713,468
2018218812,562
2019156002,578
2020286102,618
20211811603,431
20222010313,945
20233110916,002
2024299006,047
20252110855,860
2026261221—

What is it indicated for?

EndoAssist is indicated for use in general thoracoscopy, general cardiothoracic surgery, general laparoscopy, nasopharyngoscopy, ear endoscopy and sinuscopy, where a rigid laparoscope/endoscope is intended for use. A few examples of the more common endoscopic surgeries are laparoscopic* cholecystectomy hernia repair fundoplication splenectomy appendectomy hemicolectomy sympathectomy lymph node dissection hysterectomy gastric banding gastric by pass…

Read the full statement (139 words)

EndoAssist is indicated for use in general thoracoscopy, general cardiothoracic surgery, general laparoscopy, nasopharyngoscopy, ear endoscopy and sinuscopy, where a rigid laparoscope/endoscope is intended for use.

A few examples of the more common endoscopic surgeries are laparoscopic*

cholecystectomy

hernia repair

fundoplication

splenectomy

appendectomy

hemicolectomy

sympathectomy

lymph node dissection

hysterectomy

gastric banding

gastric by pass

nephrectomy

radical prostatectomy

anterior spinal fusion, decompression fixation

wedge resection

lung biopsy

pleural biopsy,

internal mammary artery dissection for coronary artery bypass

coronary artery bypass grafting where endoscopic visualization is indicated

examination of the evacuated cardiac chamber during performance of valve replacement or repair.

The users of EndoAssist are general surgeons, bariatric surgeons, gynecologists, cardiac surgeons, thoracic surgeons, orthopedic surgeons, ENT surgeons and urologists

* In this context "laparoscopic" is taken to embrace the use of a rigid endoscope in any part of the body

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K043284: Endoassist.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K043284

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026